Gardena FP 1400 E Bedienungsanleitung

Gardena pomp FP 1400 E

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Gardena FP 1400 E (10 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/10
GARDENA
®
FP 500 Art. 7647
FP 750 Art. 7648
FP 1400 Art. 7649
DBetriebsanleitung
Wasserspielpumpen- Set
GB Operating Instructions
Fountain Pump Set
FMode d’emploi
Pompe pour jets d’eau
NL Instructies voor gebruik
Vijverpompset
SBruksanvisning
Fontän Pump Set
IIstruzioni per l’uso
Set per giochi d’acqua
EManual de instrucciones
Bomba para fuentes de agua
PInstruções de utilização
Bomba para fontes
DK Brugsanvisning
Springvandspumpesæt
DGBFNLSIEPDK
8
GB
GARDENA Fountain Pump Set
FP 500 / FP 750 / FP 1400
Welcome to the Garden of GARDENA ...
Translation of the original instructions from German. Please read
these operating instructions carefully and observe the notes given.
Use the instructions to familiarise yourself with the equipment, the
operating controls, their correct use, and the notes on safety.
For safety reasons, children under 16 as well as persons not
familiar with these operating instructions must not use this
Fountain Pump Set.
vKeep these operating instructions in a safe place.
1. Where to use Your GARDENA Fountain Pump Set . . . . . . . . . . . 8
2. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. Storing your Fountain Pump Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
10. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1. Where to use Your GARDENA Fountain Pump Set
GARDENA Fountain Pumps have been designed for private use.
They are not designed for operating watering tools and systems.
The pumps may be used indoors as well as outdoors.
GARDENA Fountain Pumps have not been designed for
constant use in the industrial sector. Corrosive, easily
combustible, aggressive or explosive substances (e.g.
petrol, petroleum, nitro thinner) as well as salt-water or
food and drinking water must not be pumped.
Intended Use
Please note
2. Safety instructions
Electrical Safety:
The pump should be operated via a residual
current device with a residual current rating of
≤30 mA (DIN VDE 0100-702 and 0100-738).
The pump must be placed on solid, even
ground.
vPlease ask your electrician for his advice.
Always disconnect the pump from the
mains before undertaking any work on it.
Mains power cables should not have a smaller
cross-section than a rubber sheathed cable of
the designation H05 RN-F 3G0,75. Extension
cables must meet the requirements of DIN
VDE 0620.
Check line voltage. Data indicated on the type
plate must match technical data of the mains
supply.
Please unplug the pump after operation and
before carrying out any maintenance works.
Contents
9
GB
The pump must not be operated when there
are people in the water. Swimming pools
and garden ponds should be designed
according to international and national
design regulations.
vPlease consult a professional electrician.
For Austria:
Pumps for use on swimming pools and on
ponds may only be operated via an isolating
transformer.
vPlease consult a professional electrician.
For Switzerland :
In Switzerland mobile appliances which are
used outdoors, must be connected via a
residual-current device.
Note:
Do not allow the pump to run without
water because dry-running leads to an
undesirable build up of heat and will
destroy the pump.
Before operating the pump, look to see if there
is any damage to the pump (esp. regarding
power cable and plug). The connection cable
of the pump cannot be replaced. If the cable is
damaged the pump must be scrapped.
Do not use the power cable to carry the pump
or to pull the plug out of the socket. Protect
the power cable from heat, oil and sharp
edges.
The temperature of the liquid used must not
be below 4 °C or above 35 °C.
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.
Please observe the local noise prevention
regulations.
3. Assembly
The filter housing can be mounted on a firm surface (e.g. a flag
stone) for more secure positioning.
1. Clip nozzle pipe 1into the ball and socket joint 2.
2. Screw the water feature insert you require a) b) c)/ / into the
nozzle pipe 1.
a) cascade b) b) water bell jets of water
3Holder for GARDENA underwater light art 7951
4. Initial Operation
1. Place water feature pump on a firm base in such a way that
the filter housing 4is completely covered by water.
2. Pull telescopic pipe 5out to the desired length.
3. Plug mains plug into an AC power socket.
Warning: Pump will start immediately.
4. Set the quantity of water required for the water feature using
the regulator 6.
5. Water bell and water goblet: Screw water feature insert into
the nozzle pipe until the water feature has produced the shape
required.
Fit the pump:
Switch on water
feature pump:
3
46
5
2
1


Produktspezifikationen

Marke: Gardena
Kategorie: pomp
Modell: FP 1400 E

Brauchst du Hilfe?

Wenn Sie Hilfe mit Gardena FP 1400 E benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung pomp Gardena

Bedienungsanleitung pomp

Neueste Bedienungsanleitung für -Kategorien-