50Amp 125V/250V Female Connector
Installation Instructions
Model: F52FMP-SS
WARNING
ELECTRICAL SHOCK AND
FIRE HAZARD!
• To prevent the risk of
electrocution or re,
ensure the inlet and
connecting cables are
NOT connected to a
power source during
installation!
• Use only 6AWG or
above cable with
this product. Using a
smaller AWG cable will
result in overheating
and possible Fire
Hazard.
Cable Color Scheme
For 125V/250V 4 core cables:
Black = X - Live/Hot Cable
Red = X - Live/Hot Cable
White = W - Neutral Cable
Green = G - Ground Cable
Installation
1. Unscrew the two holding
screws from the face of
the 50amp connector to
separate the white pin
module section from the
black 50amp connectors
rear cover.
2. Remove the threaded
cable strain relief piece
from the rear cover.
3. Feed the cable through
the rear parts in the
following order:
a. Threaded plastic rear
strain relief
b. Plastic cable grip (make
sure the narrow claw
end is fed through rst)
c. Rubber strain relief
gasket
d. Rear cover.
4. Strip off 1½” of the outer
insulation layer of the
cable and strip off ” 5/8
of colored insulations
from the ends of your 3
conductor cables, making
sure you strip back to new
wire without corrosion.
5. Using a slot head screw
driver, connect the
colored wires to the
corresponding lettered
holes on the back of
the inlet, (see above for
color to letter markings)
taking care not to have
any stray wire strands, or
have insulation pushed
inside the terminal holes.
Tighten terminal screws
to 22-25 in.lbs torque.
6. Slide the rear cover
back over the terminal
connections so the
locator keys are aligned.
Using a #2 Phillips head
screwdriver, tighten the
two screws on the inlet
pin face to secure the
cover.
7. From step #3, slide in the
strain relief components
2 and 3 to the rear of the
connector cover, then
push the threaded strain
relief (1) to secure and
tighten the nut using a
1 ” wrench until the 5/8
cable is gripped. Do not
over tighten.
IG-FET00006 V2.0
Furrion Innovation Center & Institute of Technology
● 52567 Independence Ct., Elkhart, IN 46514, USA ● Toll free:1-888-354-5792
● Email: support@furrion.com
Š2007-2018 Furrion Ltd. FurrionŽ and the Furrion logo are trademarks
licensed for use by Furrion Ltd. and registered in the U.S. and other countries.
FURRION.COM


Produktspezifikationen

Marke: Furrion
Kategorie: Nicht kategorisiert
Modell: F52FMP-RY

Brauchst du Hilfe?

Wenn Sie Hilfe mit Furrion F52FMP-RY benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Furrion

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂźr -Kategorien-