Fujitsu AUTG54KRLA Bedienungsanleitung

Fujitsu Klimaanlage AUTG54KRLA

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Fujitsu AUTG54KRLA (13 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/13
AIR CONDITIONER
KEEP THIS MANUAL FOR FUTURE REFERENCE
PART No. 9381622016-03
Indoor Unit
AUTG30KRLA
AUTG36KRLA
AUTG45KRLA
AUTG54KRLA
OPERATING MANUAL
Cassette type
En-1
OPERATING MANUAL
PART No. 9381622016-03
Air Conditioner (Cassette type)
SAFETY PRECAUTIONS
To prevent personal injury, or property damage, read this
section carefully before you use this product, and be sure to
comply with the following safety precautions.
Incorrect operation due to failure to follow the instructions
may cause harm or damage, the seriousness of which is
classi ed as follows:
WARNING
This mark warns of death or serious injury.
CAUTION This mark warns of injury or damage
to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or
outdoor unit.
WARNING
This symbol shows that this appli-
ance uses a ammable refrigerant.
If the refrigerant is leaked and expo-
sure to an external ignition source,
there is a risk of re.
CAUTION This symbol shows that the Operat-
ing Manual should be read carefully.
CAUTION
This symbol shows that a service
personnel should be handling this
equipment with reference to the
Installation Manual.
CAUTION
This symbol shows that information
is available such as the Operating
Manual or Installation Manual.
WARNING
The appliance shall be installed, operated and stored in a
room with a oor area larger than X m².
30
type
M (kg) M 2.10 2.10 < M 2.50 2.50 < M 2.90
X (m2) 4.20 5.96 8.02
M (kg) 2.90 < M 3.30 3.30 < M 3.70 3.70 < M 3.90
X (m2) 10.38 13.05 14.50
36,
45
type
M (kg) M ≤ ≤ 2.85 2.85 < M 3.25 3.25 < M 3.65
X (m2) 7.74 10.07 12.70
M (kg) 3.65 < M 4.05 4.05 < M 4.25
X (m2) 15.64 17.22
54
type
M (kg) M 3.10 3.10 < M 3.50 3.50 < M 3.90
X (m2) 9.16 11.68 14.50
M (kg) 3.90 < M 4.30 4.30 < M 4.50
X (m2) 17.63 19.31
M (kg): Amount of refrigerant charge (IEC 60335-2-40)
X (m2): Minimum room area
This product contains no user-serviceable parts.
Always consult authorized service personnel for
repairing, installation, and relocation of this prod-
uct.
Improper installation or handling will cause leak-
age, electric shock, or re.
In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner,
and disconnect all the power supply by turning off
the electrical breaker or disconnecting the power
plug. Then consult authorized service personnel.
Take care not to damage the power supply cable.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
In the event of refrigerant leakage, be sure to
keep away from re or any ammables, and con-
sult authorized service personnel.
In the event of a thunder storm or any prior sign
of a lightning strike, turn off the air conditioner via
the remote controller, and refrain from touching
the product or the power source to prevent any
electrical hazards.
The appliance shall be stored in a room without
continuously operating ignition sources (for ex-
ample: open ames, an operating gas appliance
or an operating electric heater).
The appliance shall be stored in a well-ventilated
area.
Be aware that refrigerants may not contain an
odour.
The appliance shall be stored so as to prevent
mechanical damage from occurring.
Disposing of the product shall be done properly,
in compliance with national or regional regula-
tions.
This appliance is not intended for use by persons
(including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience
and knowledge, unless they have been given
supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
Do not start or stop the operation of this product
by turning on or off the circuit breaker.
Do not use in ammable gases near this product.
Do not expose yourself directly to the cooling air
ow for many hours.
Do not insert your ngers or any other objects
into outlet port or inlet port.
Do not operate with wet hands.
Do not install the unit in area lled with min-
eral oil such as a factory or area containing a
large amount of splashed oil or steam such as a
kitchen.
Do not use means to accelerate the defrosting
process or to clean the appliance, other than
those recommended by the manufacturer.
Do not pierce or burn.
CONTENTS
SAFETY PRECAUTIONS ...................................................... 1
NAME OF PARTS .................................................................. 2
FEATURES AND FUNCTIONS ............................................. 2
CLEANING AND CARE ......................................................... 3
OPERATING TIPS ................................................................. 4
TEMPERATURE AND HUMIDITY RANGE .......................... 7
TROUBLESHOOTING ........................................................... 7
WARRANTY CARD ............................................................... 8
En-2
NAME OF PARTS
Indoor unit
2-[1] 2-[2]
2-[3]
2-[4]
1
4
3
1Air lter (in air intake grille)
2Air ow direction outlet
Individual air ow direction control: [1][2][3][4]
3Air intake grille
4Human sensor
5Remote controller *
*: For detailed instructions on how to operate, please refer to
the Operating manual of the remote controller.
FEATURES AND FUNCTIONS
INVERTER
On start-up, the air conditioner will operate at maximum
capacity to bring the room quickly down to desired tempera-
ture. Once the temperature in the room begins to achieve the
set temperature, the air conditioner will reduce its capacity
and energy usage to the minimum capacity and input ratings.
VERTICAL AIR FLOW
Comfortable air ow spread to every corner of the room by
the wide vertical air ow.
INDIVIDUAL AIR FLOW DIRECTION CONTROL
Each louver can be set individually using the wired remote
controller to provide comfortable air ow.
HUMAN SENSOR
The human sensor saves energy by catching the movement
of people, operating either in a low capacity mode or stop-
ping operation when people leave the room.
[Auto Saving]
When absent continues for the set time, the operation
switches to energy saving operation.
[Auto Off]
When absent continues for the set time, indoor unit opera-
tion stops.
ECONOMY OPERATION
When ECONOMY operation mode is operated, the room
temperature will be little higher than the set-temp under
cooling mode and lower than set-temp under heating mode.
Therefore, the ECONOMY mode is able to save more energy
than other normal mode.
CAUTION
Provide occasional ventilation during use.
Always operate this product with air lters installed.
Ensure that any electronic equipment is at least
1 m away from this product.
Turn off power source when not using this prod-
uct for extended periods.
After a long period of use, ensure to get the
mounting of the indoor unit checked to prevent
this product from falling down.
The air ow direction and the room temperature
should be carefully considered when you use this
product in a room with infants, children, elderly or
sick persons.
Keep the surroundings of the outdoor unit clean
and tidy, and do not place items around it. Any
objects blocking or entering from the outlet ports
may cause product malfunction.
Do not direct the air ow at replaces or heating
apparatus.
Do not block or cover the inlet port and the outlet
port.
Do not apply any heavy pressure to radiator ns.
Do not climb on, place objects on, or hang ob-
jects from this product.
Do not place any other electrical products or
household belongings under this product.
Dripping condensation from this product might
get them wet, and may cause damage or mal-
function of your property.
Do not expose this product directly to water.
Do not use this product for preservation of food,
plants, animals, precision equipment, art work, or
other objects. This may cause quality deteriora-
tion of those items.
Do not expose animals or plants to the direct air
ow.
Do not drink the drainage from the air conditioner.
Do not pull the power supply cable.
Do not touch the aluminium ns of heat exchang-
er built-in this product to avoid personal injury
when you install or maintain the unit.
Do not stand on unstable steps when operating
or cleaning this product. It may overturn and can
cause injury.


Produktspezifikationen

Marke: Fujitsu
Kategorie: Klimaanlage
Modell: AUTG54KRLA

Brauchst du Hilfe?

Wenn Sie Hilfe mit Fujitsu AUTG54KRLA benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Fujitsu

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-