Fujitsu ASYG14KGTA Bedienungsanleitung

Fujitsu Klimaanlage ASYG14KGTA

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Fujitsu ASYG14KGTA (13 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 14 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/13
En-1
AIR CONDITIONER
Wall Mounted Type
OPERATING MANUAL
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Safety Precautions
To prevent personal injury, or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classied as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED. This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant is leaked and exposed to an external
ignition source, there is a risk of re.
CAUTION This symbol shows that the operation manual should be read carefully.
CAUTION This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
CAUTION This symbol shows that information is available such as the operating manual or installation manual.
WARNING
This product contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
In the event of a thunder storm or any prior sign of a lightning
strike, turn off the air conditioner via the remote controller,
and refrain from touching the product or the power source to
prevent any electrical hazards.
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
The appliance shall be stored in a well-ventilated area.
Be aware that refrigerants may not contain an odour.
The appliance shall be stored so as to prevent mechanical
damage from occurring.
Disposing of the product shall be done properly, in
compliance with national or regional regulations.
During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
Do not start or stop the operation of this product by inserting or
pulling out the power plug, or by turning on or off the circuit breaker.
Do not use ammable gases near this product.
Do not expose yourself directly to the cooling airow for
many hours.
Do not insert your ngers or any other objects into outlet
port, open panel, or intake grille.
Do not operate with wet hands.
Do not install the unit in area lled with mineral oil such as a
factory or area containing a large amount of splashed oil or
steam such as a kitchen.
Do not use means to accelerate the defrosting process or to
clean the appliance, other than those recommended by the
manufacturer.
Do not pierce or burn.
Contents
Safety Precautions 1 ...............................................................
Indoor Unit Overview and Operations 3 ..................................
Remote Controller Overview and Operations 4 .......................
Timer Operation.................................................................... 6
Human Sensor (Energy Saving) 8 ...........................................
General Information on Operation 9 ........................................
Cleaning and Care.............................................................. 10
Troubleshooting 12 ..................................................................
PART No. 9387602005-02 [Original instructions]
EnglishDeutschFrançaisEspañolItalianoEλληvIkάPortuguêsРусскийTürkçe
En-2 OPERATING MANUAL
Indoor unit accessories
Remote
controller
Batteries Filter holdersAir cleaning lters
Remote controller
holder
Tapping screws
Remote controller holder installation
321
Screws
Insert
Slide up
WARNING
Take care to prevent infants and young children from acciden-
tally swallowing the batteries.
CAUTION
Do not attempt to recharge dry batteries.
Do not use dry batteries that has been recharged.
Battery (R03/LR03/AAA × 2) loading and remote controller preparation
4
2
3
16
7
8
5
9
5 Press the "CLOCK ADJUST" button to start clock setting.
6 Set the day of the week by pressing "SELECT" button (Monday
to Sunday). *By pressing the "TEMP."
( / ) buttons, the time
indicator can be changed from a 24-hour to a 12-hour clock.
7 Press "NEXT" button to continue.
8 Set the time by pressing "SELECT" button.
Pressing or changes the value by the minute.
Pressing down on or changes the value by 10 minutes.
9 To complete, press the "SEND" button close to the indoor unit.
Settings may not be properly sent if pressed from a distance.
NOTES:
Use specied type of batteries only.
Do not mix different types or new and used batteries together.
Batteries can be used about 1 year in ordinary use.
If the remote control range noticeably shortens, replace the batter-
ies, and press the "RESET" button as shown in page 5.
CAUTION
Provide occasional ventilation during use.
Always operate the unit with air lters installed.
Ensure that any electronic equipment is at least 1 m (40 in)
away from either the indoor unit or outdoor unit.
Disconnect all the power supply when you are not using this
product for extended periods.
After a long period of use, ensure to get the mounting of the
indoor unit checked to prevent this product from falling down.
The airow direction and the room temperature should be
carefully considered when you use this product in a room
with infants, children, elderly or sick persons.
Do not place any other electrical products or household
belongings under this product.
Dripping condensation from this product might get them wet,
and may cause damage or malfunction of your property.
Do not expose this product directly to water.
Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects. This
may cause quality deterioration of those items.
Do not expose animals or plants to the direct airow.
Do not drink the drainage from the air conditioner.
Do not pull the power supply cable to disconnect the plug.
Do not touch the aluminum ns of heat exchanger built-in
this product to avoid personal injury when you maintain the
unit.
Do not stand on unstable steps when operating or cleaning
this product. It may overturn and can cause injury.
Do not direct the airow at replaces or heating apparatus.
Do not block or cover the intake grille and the outlet port.
Do not apply any heavy pressure to radiator ns.
Do not climb on, place objects on, or hang objects from this
product.
This product contains uorinated greenhouse gases.
En-3
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing may have an effect on the proper
function or performance of the product.
2 "MANUAL AUTO" button
Use when the remote controller is lost or there is a malfunction.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
less than 10 seconds.
Auto
Press more than 10 seconds.
(Only for servicing.*)
Forced cooling
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop the Forced cooling, press this button or Start/Stop button on
the remote controller.
3 Front panel
See page 8
4 Human Sensor
Used for Energy Saving Function. Controls temperature setting by
detecting people in the room.
5 Vertical airow direction louver
Each time you press the "SET" button on the remote controller, the
angle of the vertical airow direction louver moves as follows:
1
2
3
4
56
Cooling or Dry
mode Heating mode
1 2 3 65
* *
4
*: Default setting in each mode.
Do not adjust by hand.
At the beginning of Auto or Heating mode, they may stay on position
1 for a while for adjustment.
If the angle is set to position 4-6 for more than 30 minutes in Cooling
or Dry mode, the louver will automatically return to position 3.
Keeping the position 4-6 during Cooling or Dry mode may cause
condensation to form, and the drops may damage your property.
6 Drain hose
7 Remote controller signal receiver
CAUTION
For appropriate signal transmission between remote controller
and indoor unit, keep the signal receiver away from the follow-
ing items:
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as
inverter type ones, the signal may not be transmitted properly.
In such a case, consult the store of purchase.
6
9
8
10
13
1
2
3
4
5
7
12
11
8
Economy indicator (green)
Lights in the Economy operation and in the 10 °C Heat operation.
9
Timer indicator (orange)
Lights in the Timer operation, and blinks slowly when the timer setting
error is detected.
For details, refer to “Auto-restart function” on page 9.
10 Operation indicator (green)
Lights in the normal operation, and blinks slowly in the Automatic
defrosting operation.
11
Horizontal airow direction louvers
CAUTION
Before you adjust the horizontal airow direction, make sure
that the vertical airow direction louver has been stopped
completely.
Adjust two knobs by hand.
See page 10
12
Air lter
See page 11
13
Air cleaning lters
Purify or deodorize the air, and provide fresh airow.
Indoor Unit Overview and Operations


Produktspezifikationen

Marke: Fujitsu
Kategorie: Klimaanlage
Modell: ASYG14KGTA
Produktfarbe: Weiß
Fernbedienung enthalten: Ja
Typ: Klimaanlageneinheit Innen
Kältemittelart: R32
Kühlmittelgewicht: 850 g
Invertertechnologie: Ja
Klimaanlage Funktionen: Circulation, Cooling, Dehumidifying, Fan, Heating, Ventilating
Kühlkapazität in Watt (nominal): - W
Energieeffizienzklasse (Kühlen): A++
Energieverbrauch pro Stunde (Kühlung): 4.2 kWh
Energieverbrauch pro Stunde (Heizung): 5.4 kWh
Jährlicher Energieverbrauch (Kühlung): 207 kWh
Saisonaler Wirkungsgrad (Kühlung) (SEER): 7.11
Heizleistung in Watt (nominal) (wärmere Heizperiode): - W
Heizleistung in Watt (nominal) (durchschnittliche Heizperiode): - W
Heizleistung in Watt (nominal) (kältere Heizperiode): - W
Betriebstemperaturbereich (Kühlung) (T-T): -10 - 46 °C
Betriebstemperaturbereich (Heizung) (T-T): -15 - 24 °C
Energieeffizienzklasse (Heizung) (SCOOP) (durchschnittliche Heizperiode): A+
Jährlicher Energieverbrauch (Heizung) (wärmere Heizperiode): 1298 kWh
Jährlicher Energieverbrauch (Heizung) (durchschnittliche Heizperiode): - kWh
Jährlicher Energieverbrauch (Heizung) (kältere Heizperiode): - kWh
zulässige Last (Kühlung): 4.2 kW
zulässige Last (Heizung) (wärmere Heizperiode): 4 kW
zulässige Last (Heizung) (durchschnittliche Heizperiode): - kW
zulässige Last (Heizung) (kältere Heizperiode): - kW
Indooreinheitstyp: Wandmontierbar
Geräuschpegel Innengerät (hohe Geschwindigkeit): 44 dB
Kühlender Luftstrom (indoor unit): 770 m³/h
Anzahl Innengeräte: 1
Breite der Indooreinheit: 834 mm
Tiefe der Indooreinheit: 215 mm
Höhe der Indooreinheit: 270 mm
Innengerätgewicht: 10000 g
Geräuschpegel Außengerät: - dB
Geräuschpegel Innengerät (geringe Geschwindigkeit): 24 dB
Komfort-Schlafmodus: Ja
Strom (Kühlung): 9 A
Kühlung Energieeffizienz: 3.57
Heizung Energieeffizienz: 4
Deshumidifizierende Kapazität: 2.1 l/h
Strom (Heizung): 10.5 A
Saisonaler Wirkungsgrad (Heizung) (SCOP): 4.31
Innengerät Schallleistungspegel: 57 dB

Brauchst du Hilfe?

Wenn Sie Hilfe mit Fujitsu ASYG14KGTA benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Fujitsu

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-