Fujitsu ARTG12LLLB Bedienungsanleitung

Fujitsu Klimaanlage ARTG12LLLB

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Fujitsu ARTG12LLLB (20 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 2 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/20
HEAT & COOL MODEL
(REVERSE CYCLE)
AIR CONDITIONER
Duct Type
Indoor Unit
ARTG09LL
ARTG12LL
ARTG18LL
OPERATING MANUAL
KEEP THIS MANUAL FOR FUTURE REFERENCE
P/N9374379439
En-1
CONTENTS
SAFETY PRECAUTIONS ........................................ 1
FEATURES AND FUNCTIONS ............................... 2
NAME OF PARTS ................................................... 3
PREPARATORY OPERATION ................................ 4
OPERATION ........................................................... 5
TIMER FUNCTIONS ............................................... 7
ON/OFF TIMER ....................................................... 7
SAFETY PRECAUTIONS
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service person-
nel for repairs.
When moving, consult authorized service personnel for disconnection and installation
of the air conditioner.
Do not become excessively chilled by staying for many hours in the direct cooling
air ow.
Do not insert ngers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by turning off the electrical breaker and so on
.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off
the electrical breaker, and consult authorized service personnel.
In the event of refrigerant leakage, be sure to keep away from re or any ammables.
(consult an authorized service personnel)
Provide occasional ventilation during use.
Do not direct air ow at replaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set ower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not touch the switches with sharp objects.
Turn off power source when not using the unit for extended periods.
Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air lter
.
Connection valves become hot during Heating; handle with care.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air ow.
When restarting after a long period of disuse in the winter, turn the power switch on at
least 12 hours before starting the unit.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator ns.
Operate only with air lters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least 1m away from either the indoor or
outdoor units.
Avoid installing the air conditioner near a replace or other heating apparatus.
When installing the indoor and outdoor units, take precautions to prevent access by infants
.
Do not use in ammable gases near the air conditioner.
Install the drain hose so that it drains water properly.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
Before using the appliance, read these “SAFETY PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
WEEKLY TIMER ...................................................... 8
TEMPERATURE SET BACK TIMER ..................... 10
ECONOMY OPERATION .......................................11
CLEANING AND CARE ..........................................11
TROUBLESHOOTING .......................................... 12
OPERATING TIPS ................................................. 14
SELF-DIAGNOSIS ................................................ 16
DANGER! This mark indicates procedures which, if improperly performed, are most likely to
result in the death or serious injury to the user or service personnel.
WARNING! This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user or service personnel.
CAUTION! This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
DANGER!
CAUTION!
En-2
FEATURES AND FUNCTIONS
INVERTER
At the start of operation, large amount of power is used to
bring the room quickly to the desired temperature. Afterwards,
the unit automatically switches to a low power setting for eco-
nomic and comfortable operation.
ECONOMY OPERATION
When ECONOMY operation mode is operated, the room tem-
perature will be little higher than the set-temp under cooling
mode and lower than set-temp under heating mode. Therefore,
the ECONOMY mode is able to save more energy than other
normal mode.
SUPER QUIET OPERATION
When the FAN button is used to select QUIET, the indoor unit
begins super quiet operation; the indoor unit’s airflow is re-
duced to produce quieter operation.
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched auto-
matically to maintain the set temperature, and the temperature
is kept constant at all times.
Convenient function
WEEKLY TIMER
Use this timer function to set operating times for each day of
the week. Use the DAY OFF setting to switch off timed opera-
tion for a selected day in the coming week. Because all days
can be set together, the weekly timer can be used to repeat
the timer settings for all of the days.
TEMPERATURE SET BACK TIMER
Use this timer function to change the set temperature in the
operation times set for each day of the week. This can be used
together with other timer settings.
REMOVABLE AIR FILTER
The indoor unit’s air lter can be removed for easy cleaning
and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.
Remote controller
WIRED REMOTE CONTROLLER
The wired remote controller allows convenient control of indoor
unit operation.
WIRELESS REMOTE CONTROLLER (OPTION)
The optional wireless remote controller can be used. When you
use remote controller, there are following different points as
compared with using wired remote controller.
[ The additional function for wireless ones ]
SLEEP
TIMER
10°C HEAT
And you can use both wireless and wired remote controller si-
multaneously. (But function is limited.)
[ The restricted functions for wired ones ]
Weekly timer
Temperature set back timer
Energy saving and
Comfortable function
Clean function


Produktspezifikationen

Marke: Fujitsu
Kategorie: Klimaanlage
Modell: ARTG12LLLB

Brauchst du Hilfe?

Wenn Sie Hilfe mit Fujitsu ARTG12LLLB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Fujitsu

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-