Friedland SA5 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Friedland SA5 (52 Seiten) in der Kategorie Sicherheitskamera. Dieser Bedienungsanleitung war für 36 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/52
ESC ENTER
2
6
7 9
#
*
8
5
3
1
4
0
Installation & Operating Manual
SA5
6 Zone Communicating
Wirefree
Alarm System
FOREWORD
All components in this wirefree Alarm System are
designed and manufactured to provide a high standard
of security protection and long, reliable service.
The system is designed for ease of installation using only
conventional domestic tools. However, it is essential that
the installer reads and fully understands the advice and
procedures contained in this manual and plans the
system before proceeding with the installation.
During installation, it is important that the procedures
described in this manual are followed in sequence.
This manual should be retained in a safe place for
future reference.
No radio operating licence is required for this equipment.
IMPORTANT
All components, with the exception of the External
Solar Siren are suitable for mounting in dry interior
locations only.
DECLARATION
Novar ED&S hereby declares that this wirefree alarm
system is in compliance with the essential
requirements and other relevant provisions of the
Radio and Telecommunications Terminal Equipment
(R&TTE) directive, 1999/5/EC.
Tools and Equipment Required:
No.0, No.1 and No.2 Philips Screwdrivers
5 & 6mm Masonry Drill Bits
Drill, Bradawl, Small Spirit Level
SAFETY
Always follow the manufacturers advice when using
power tools; steps, ladders etc. and wear suitable
protective equipment (e.g. safety goggles) when
drilling holes etc.
Before drilling holes in walls, check for hidden electricity
cables and water pipes, the use of a cable/pipe locater
maybe advisable if in doubt.
When using ladders, ensure that they are positioned on
a firm stable surface at the correct angle and suitably
secured before use.
The use of ear defenders is advisable when working in
close proximity to the Siren due to the high sound
level produced by this device.
DEVICE RANGE
The quoted range of the system devices (see
component specification on rear cover) is measured in
ideal conditions. Any solid object (e.g. walls, ceilings,
reinforced PVC doors etc) placed between the
transmitter and Receiver device will reduce the
transmission range of the devices.
The amount by which the range will be reduced is
dependant upon the nature of the barrier. e.g.
Wall Type Range Reduction
Dry-lined partition wall: 10-30%
Single layer brick wall: 20-40%
Double layer brick wall: 30-70%
Metal Panel/Radiator: 90-100%
Note: The effect on the range of multiple walls is
cumulative. i.e. if there are two brick walls in the way,
the range will be reduced by up to 40% by each wall.
SYSTEM SECURITY
This system has been designed to both detect
intruders and act as a strong deterrent to would-be
intruders when installed correctly.
Please remember that given adequate knowledge and
time it is possible to overcome any alarm system and
we therefore recommend that an Intruder Alarm is
used in conjunction with good physical protection
such as security window and door locks.
All units in the system are encoded to operate together
using an 8 bit House Code which is configured by the
user/installer to provide the identification code for your
installation. The system House Code can be changed
at any time by the user.
The system is operated from one or more Remote
Control units and/or the Control Panel. Care should
be taken to ensure that your Remote Control Unit(s)
are not lost or the User Access Codes for the Control
Panel do not become known to other people as this
will compromise the security of your system. In either
event the system house code and User Access Codes
should be changed as soon as possible.
SA5 6 Zone Communicating Wirefree Alarm SystemFriedland
IMPORTANT: All units in your system must be set
to the same House Code which must be changed
from the factory supplied setting.
CONTENTS
Page No.
KIT CONTENTS 2
INTRODUCTION AND OVERVIEW
3
Multiple Users 3
System Arming 3
Entry/Exit Delay 3
Zones 3
Zone Lockout 4
Quick Set 4
Final Exit Set Zone 4
Walk Through Zone 4
Omit Zone 4
Event Log 4
Chime 4
Voice Dialler 4
Remote Manager 4
Latch-Key 5
Answer-Phone 5
Voice Memo 5
Remote System Control 5
Tamper Protection 5
Jamming Detection 5
Battery Monitoring 5
System House Code 6
PLANNING AND EXTENDING YOUR
WIREFREE ALARM SYSTEM 7
REMOTE CONTROL UNIT 8
General Information 8
Configuring the Remote Control 9
CONTROL PANEL 9
Positioning the Control Panel 9
Installing the Control Panel 10
Configuring the Control Panel House Code 11
Testing the Control Panel & Remote Control 11
PASSIVE INFRA RED (PIR)
MOVEMENT DETECTORS 12
Positioning the PIR Movement Detectors 12
Installing and Configuring the PIR
Movement Detectors 13
Testing the PIR Movement Detectors 14
MAGNETIC CONTACT DETECTORS 14
Positioning the Magnetic Contact Detectors 15
Installing and Configuring the Magnetic
Contact Detector 15
Testing the Magnetic Contact Detector 16
EXTERNAL SOLAR SIREN 17
General Information 17
Positioning the Solar Siren 17
Page No.
Installing and Configuring the Solar Siren 17
Power-up of the Solar Siren 19
Testing the Solar Siren 19
EXTERNAL CONNECTIONS 19
TESTING THE SYSTEM 20
Initial Testing 20
Testing an Installed System 20
DEFAULT SETTINGS 22
Reset Factory Default Conditions 22
PROGRAMMING 23
User Setup 24
System Setup 25
Zone Setup 28
Voice Dialler Setup 30
Full Arm Setup 32
Part-Arm 1 Setup 33
Part-Arm 2 Setup 34
Time & Date Setup 35
Latch Key Setup 35
Answer Phone Setup 36
Remote manager Setup 37
OPERATING INSTRUCTIONS 38
Arming The System 38
Part-Arming The System: Part-Arm 1 38
Part-Arming The System: Part-Arm 2 38
Disarming the System 39
Quick Set 39
Omit Zone 39
Personal Attack (PA) Alarm 39
Tamper 39
Chime 39
Event-Log 40
Leaving a Voice Memo Message 40
Replaying and Deleting Messages at the
Control Panel 40
Remote Phone Access and Control 40
Siren Service Mode 41
Siren Operating Mode 42
Battery Monitoring 42
MAINTENANCE 43
ALARM RECORD 44
TROUBLE SHOOTING 45
EXTENDING YOUR ALARM SYSTEM 48
COMPONENT SPECIFICATION
Back Cover
1SA5

Produktspezifikationen

Marke: Friedland
Kategorie: Sicherheitskamera
Modell: SA5

Brauchst du Hilfe?

Wenn Sie Hilfe mit Friedland SA5 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Sicherheitskamera Friedland

Bedienungsanleitung Sicherheitskamera

Neueste Bedienungsanleitung für -Kategorien-