Seite 1/5
®
80PT-25
SureGripTM Piercing
Temperature Probe
Instruction Sheet
XWWarning
To avoid electrical shock, do not use this
probe when voltages exceeding 24 V ac rms
or 60 V dc are present. The probe tip is
electronically connected to the output
terminals.
Introduction
The 80PT-25 SureGripTM Piercing Temperature Probe is
designed for use in liquids, gels, soft, and semi-hard
materials. The probe is made of 316 stainless steel, which
is suitable for food service use. The thermocouple junction
of the probe is protected from tip to handle by the stainless
steel sheath. The 40-inch (1-meter) cable is terminated
with a Type T miniature thermocouple connector with
0.792-mm (.312-inch) pin spacing. The 80PT-25 can be
used with any temperature-measuring instrument that is
designed to accept Type T thermocouples and has a
miniature connector input.
Specifications
Type
T, Copper/Constantan
Measurement Range of Stainless Steel Probe
-196 °C to 350 °C (-320.8 °F to 662 °F)
Accuracy
(With respect to ANSI MC96.1 Standard Limits of Error)
Note
All error calculations should be done in
°
C and
then scaled to
°
F.
Range Accuracy
(% of reading)
-196 °C to -150 °C
(-320.8 °F to -238 °F)
±3 %
-150 °C to -40 °C
(-238 °F to -40 °F)
±2 °C
-40 ° °C to 0 C
(-40 °F to 32 °F)
±1 °C
0 °C to 350 °C
(32 °F to 662 °F)
Max
(±1 °C, ±0.75 % of reading)
November 20 4 0
© 2004 Fluke Cor oratio . rig ts r ser ed. p n All h e v
All product names are trademarks of their respective companies
Output
@ 25 °C (77 °F) =1.00 mV (reference junction at 0 °C)
Seebeck Coefficient @ 25 °C (77 °F) = 40.50 µV / °C
Measurement Time (Time Constant): 3.0 seconds in 100
°C still water at sea level pressure (5 time
constants = 1 complete step change, i.e., 5 seconds)
Maximum Voltage 24 V ac rms or 60 V dc
Maximum Temperature of Tip 816 °C (1500 °F)
Sheath
Material: 316 Stainless Steel Dimensions
Diameter: 3.4036 mm (.134 in)
Length: 10.16 cm (4 in)
Tip: 25 ° conical
Grounding Junction welded to sheath
Cable
Length: 40 inches (1 meter)
Insulation
Material: PVC
Maximum Temperature: 105 °C (221 °F)
Jacket Color: Gray
Food Service Limitation: The cable should not come in
contact with food.
Conductors
Type: T
Size: AWG #24 stranded (7 strands of #32)
Handle
Material: Hytrel (food service grade)
Maximum Temperature of Food in Contact with Handle:
65 °C (150 °F)
Connector
Type: Mini-thermocouple connector with .792 mm
(.0312 in) pin spacing
Material: Blue Hytrel (food service grade)
Maximum Temperature: 125 °C (257 °F)
Overall Probe Length 22.23 cm (8.75 in) from tip to end of
cable strain relief
Protection Class 3. Relates solely to insulation and
grounding properties defined in IEC 348.
Measurement Considerations
Instrument Compatibility
The 80PT-25 is compatible with any temperature-
measuring instrument that accepts Type K thermocouples,
has a miniature thermocouple connector, and has cold
reference junction compensation. Accuracy of the
temperature-measuring instrument must be considered
along with the 80PT-25 accuracy specification to
determine the overall accuracy of the combination.
Temperature Limitations
The tip of the 80PT-25 has a continuous temperature
rating of 350 °C (662 °F). However the opposite end of the
sheath nearest the handle should not be subjected to
temperatures greater than 125 °C. This is the maximum
temperature limitation of the Hytrel handle. See Food
Service Limitations.
Exposure Limitations
The sheath material of the 80PT-25 is stainless steel. It
should not be exposed to halides or sulfides.
Food Service Limitations
The 316 stainless steel probe is suitable for contact with
hot or cold foods within the specified temperature range of
the probe. However the handle is made of Hytrel 5556
which is suitable for repeat food contact only under the
following conditions: food temperature under 65 °C
(150 °F), food alcohol content under 8 %. Food may be
wet, dry, or fatty. Also, the cable should not come in
contact with food.
Operation
Use the 80PT-25 as follows:
1. Connect the 80PT-25 to a compatible Type T
measuring instrument using the miniature (0.312 inch
spacing) thermocouple connector.
2. Turn on the measuring instrument, and select the
appropriate range and scale.
3. Check the read out on the measuring instrument. With
no heat or cold source applied to the bead, the
measuring instrument should display the ambient
(room) temperature. If the instrument does not read
out properly, refer to “Troubleshooting”.
Measuring Technique
The 80PT-25 should be inserted at least 31.75 mm
(1.25 in) into the substance to be measured to minimize
the shunting effect of the sheath.


Produktspezifikationen

Marke: Fluke
Kategorie: Nicht kategorisiert
Modell: SureGrip 80PT-25

Brauchst du Hilfe?

Wenn Sie Hilfe mit Fluke SureGrip 80PT-25 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Fluke

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-