First Alert ZCOMBO Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für First Alert ZCOMBO (2 Seiten) in der Kategorie Rauchmelder. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
CAT. ZCOMBO-G
Z-WAVE WIRELESS
INTERCONNECT
Communicates with First Alert protocol
enabled Z-Wave technology wireless
hubs. Note: This alarm will not connect
to Onelink or BRK Wireless Interconnect
alarms. Z-Wave hub not included.
PHOTOELECTRIC
Photoelectric technology is generally
more sensitive at detecting large par-
ticles, which tend to be produced in
greater amounts by smoldering res.
SILENCE FEATURE
Silences nuisance alarms.
TAMPER RESISTANT
Locks alarm to mounting bracket to
prevent removal of battery and/or alarm.
Perfect for apartment, dormitory or hotel
applications.
Description:
BRK ZCOMBO-G (model ZCOMBO) is a single station combination smoke and CO
alarm specifically designed for residential and institutional applications includ-
ing sleeping rooms of hospitals, hotels, motels, dormitories, and other multifamily
dwellings as defined in standard NFPA 101. BRK ZCOMBO-G has been fully tested
and complies with, UL217, UL2034, CSFM, NFPA 72, NFPA 720 and NFPA 101 and
other agencies that model their codes after the above agencies. It meets building
codes where battery operated Z-Wave wireless smoke and CO alarms are required
along with silence features and with model building codes published by the ICC.
BRK ZCOMBO-G is a state of the art wireless combination smoke and CO alarm
designed to provide early warning of a re or CO. It features a fully insect screened
Photoelectric smoke sensing chamber and an electrochemical carbon monoxide
sensor, an 85dB horn, a supervised 3V (2 AA batteries) power supply, a full func-
tion test switch and a silence feature. This combination alarm will operate with 3rd
party, certified Z-Wave devices enabled with the First Alert protocol and the basic
command class required by all Z-Wave devices. By the requirements of the Device
Class spec, this command class does not have to be mapped to any particular
functionality for this device. The alarm supports one association group with up
to 1 node, and sends its alarms to that group. The alarm supports configuration
parameter #1, which has a size of 1, a default value of 0, and when set to 1 causes
the device to send double alarm messages.
It also features tamper resistant locking pins that lock alarm to the mounting
bracket and battery drawer to prevent removal of battery or alarm. Perfect for
apartment, dormitory or hotel applications. Designed for wall or ceiling mounting.
Includes mounting anchors and screws.
3V (2 AA) Battery Powered
P H O T O E L E C T R I C
SMOKE & CO
COMBO
A L A R M
7
CAT. ZCOMBO-G
ARCHITECTURAL AND ENGINEERING SPEC
TECHNICAL SPECS
SHIPPING SPECS
INSTALLATION OF ALARM
The combination smoke and CO alarm shall be a BRK Model ZCOMBO (cat. no.
ZCOMBO-G) and shall provide at a minimum the following features and functions:
1. A photoelectric smoke sensing chamber and an electrochemical CO sensor.
2. Operates with 3rd party, certified Z-Wave devices enabled with the First Alert
protocol.
3. The unit shall have a lower and varying horn frequency to make it easier for the
elderly with normal age related hearing loss to better hear the horn.
4. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not
alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the
following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10
and 50 minutes and 70 PPM CO between 60 and 240 minutes.
5. The unit shall have an “End of Life” signal. This signal should be capable of
temporarily being silenced for up to 2 days. After about 2 days, the signal will
resume. After about 2-3 weeks the signal cannot be silenced.
6. A fully screened sensing chamber to resist entry of small insects.
7. Powered by 2 replaceable AA batteries, a solid state horn rated at 85dB at 10 ft and
should be capable of self restoring.
8. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
9. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8
hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
10. Two Locking features - tamper resistant locking pins that lock battery drawer and/
or alarm to mounting bracket.
11. The unit shall be capable of operating between 4F (4°C) and 100°F (38°C) and
relative humidity between 10% and 95%.
12. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
13. The unit shall at a minimum meet the requirements of UL217, UL2034, CSFM, NFPA
72, NFPA 720, NFPA 101, ICC.
Alarm Dimensions: 5.0”Dia. x 2.0”H
Weight: 8.4 oz
Operating Voltage: 3V (Two 1.5V AA) Battery Powered
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Wireless Frequency: Z-Wave
Test/Silence: Electronically simulates smoke and CO condition,
causing the unit to alarm. Press and hold test/silence
button.
Alarm Reset: Automatic when smoke and/or CO clears
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Listing: Listed to UL217 and UL2034 Standards
Individual Clamshell Dimensions 7.00”W x 2.5”D x 8.375”H
Weight 0.78 lbs.
Cube 0.09 ft3
UPC 0 29054 01302 6
Master Carton Dimensions 7.63”L x 7.13”W x 8.88”H
Master Pack 3
Weight 2.65 lbs.
Cube: 0.30 ft3
I2of5: 300 29054 01302 7
Pallet Information
Cases per Layer 30
Number of Layers: 5
Cases per Pallet: 150
Units per Pallet: 450
Cube: 50 ft3
Weight: 463 lbs.
Installation of this alarm must conform to NFPA 72 and NFPA 720. Always check your
local building codes. Follow all instructions for placement as outlined in the users manual
in sections titled “Recommended Locations for Smoke Alarms and “Locations to Avoid
for Smoke Alarms”.
THE PARTS OF THIS ALARM
TOP OF ALARM
1. Test/Silence button
2. Slide open battery drawer
3. Power/Alarm LED
4. CO Alarm LED
5. Horn
BOTTOM OF ALARM
1. Mounting bracket
2. Mounting Slots & Locking
tabs (Break out Tab)
3. Battery Drawer - Install 2 AA
batteries here
4. Twist to attach and remove
alarm from bracket
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
5.0
2.0
5
3
1
2
4
TOP BOTTOM
BATTERY DRAWER LOCK
Remove pin from mounting bracket. Close door. Insert
pin in holes through alarm and battery drawer.
©2015 BRK Brands, Inc. a Jarden Corporation Company (NYSE:
JAH); 3901 Liberty Street Road Aurora, IL 60504-8122; All rights
reserved. First Alert is a registered trademark of the First Alert
Trust. BRK is a registered trademark of BRK Brands, Inc.
CM3238
brkelectronics.com
This product is intended for non-professional do it yourself installation. If you
would like information about a professionally installed and monitored system,
please contact First Alert Professional at 1-800-921-6025. First Alert Profes-
sional is not affiliated with BRK Brands, Inc.


Produktspezifikationen

Marke: First Alert
Kategorie: Rauchmelder
Modell: ZCOMBO

Brauchst du Hilfe?

Wenn Sie Hilfe mit First Alert ZCOMBO benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Rauchmelder First Alert

Bedienungsanleitung Rauchmelder

Neueste Bedienungsanleitung für -Kategorien-