Appr. nr. B98.01 A - CE 0063 AT 4967
MODENA 80 E
COPPER WALL OUNTED-M COMBINATION,
GAS FIRED BOILER FOR CENTRAL HEATING
AND D H WOMESTIC OT ATER RODUCTION P ,
FAN ASSISTED, ROOM SEALED COMPARTMENT,
ELECTRONIC FLAME IGNITION AND CONTROL
3543230/2 - 10/99
INSTALLATION, SERVICING AND
USER INSTRUCTIONS
G.C. NO: 47-267-05
MODENA 80 E
2
CE MARK
CE mark documents that the Ferroli gas appliances comply with the requirement contained in European
directives applicable to them.
In particular, the appliances comply with the following CEE directives and the technical specifications
provided from them:
• Gas appliances directive 90/396
• Efficiencies directive 92/42
• Low tension directive 73/23 (modified from the 93/68)
• Electromagnetic compatibility directive 89/396 (modified from the 93/68)
Year 2000 Compliance Declaration
We will guarantee that this products is altogether suitable for the data change in the Year 2000 (boiler has
no dependence from date change) and that no disruptions will occur which is caused by this product.
IMPORTANT
From the 1st October 1999 your "benchmark" Installation, Commissioning and Service Record Log
Book will be enclosed in your customer information pack.
"This record must be completed and left with the end user"
Ferroli is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark
has been introduced to improve the standards of installation and commissioning of central heating
systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety
and efficiency.
INDEX
1. DESCRIPTION ....................................................................................................................................... 3
2. TECHNICAL AND DIMENSIONAL CHARACTERISTICS ...................................................................... 4
3. INSTALLATION DETAILS ....................................................................................................................... 9
4. COMMISSIONING AND TESTING ..................................................................................................... 22
5. ADJUSTMENT AND GAS CONVERSION ........................................................................................... 23
6. MAINTENANCE AND CLEANING ..................................................................................................... 25
7. REPLACEMENT OF PARTS ................................................................................................................. 27
8. FAULT FINDING .................................................................................................................................. 32
9. ELECTRICAL AND FUNCTIONAL SCHEME....................................................................................... 39
10. USER INSTRUCTIONS....................................................................................................................... 41
MODENA 80 E
3
1. DESCRIPTION
1.01 Introduction
The Modena 80 E is defined as a “room sealed” combination boiler, all air required for combustion is taken from
outside the room in which it is installed. It is a new high performance gas fired heat generator for central heating and
domestic hot water production. A special feature of this boiler is its built-in electronic flame ignition and control unit
making burner operation completely automatic and safe. The main components are as follows:
• Copper heat exchanger consisting of three finned tubes specifically shaped for high efficiency.
• There are three copper coils inserted in the three heating circuit tubes. These represent the domestic hot water
heat exchanger. Their shape and high exchange surface area enable the full output of the boiler to be absorbed.
• Ceramic fibre insulated combustion chamber
• 12 stainless steel bladed burners specifically designed for this boiler.
• Fan for discharge of combustion products and intake of combustion air.
• Differential air pressure switch. For safety reasons, this ensures the burner ignites only when the fan is functioning correctly.
• Hermetically sealed compartment made from corrosion-resistant steel enclosing the above components.
• Combination gas safety valve with modulator, complete with pressure stabiliser.
• Flowmeter giving the domestic hot water circuit precedence over the central heating circuit.
• Pressure relief valve for the central heating circuit set to open at 3 bar.
• Built-in Expansion vessel.
• Variable speed pump.
• Central heating flow temperature adjustment thermostat.
• Domestic hot water flow temperature adjustment thermostat.
• Central heating limit thermostat.
• Overheat safety thermostat.
• Electronic control unit for automatic flame ignition and control.
• Central heating low water pressure cut off switch.
• Domestic hot water flow temperature sensor.
• Central heating flow temperature sensor.
1.02 Instructions and regulations
Assembly, installation, first start up and maintenance must be carried out by competent persons only, in accordance
with all current technical regulations and directives.
c.o.s.h.h.
Materials used in the manufacture of this appliance are non hazardous and no special precautions are required
when servicing.
Related Documents
This appliance must be installed strictly in accordance with these instructions.
The Gas Safety Regulations (Installations & Use) 1996.
The Local Building Regulations.
The Building Regulations.
The Buildings Standards (Scotland - Consolidated) Regulations.
British Standards Codes of Practice:
B.S. 7593 1992 TREATMENT OF WATER IN DOMESTIC HOT WATER CENTRAL HEATING SYSTEMS
B.S. 5546 1990 INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES
B.S. 5440 PART 1 FLUES
B.S. 5440 PART 2 AIR SUPPLY
B.S. 5449 1990 FORCED CIRCULATION HOT WATER SYSTEMS
B.S. 6798 1987 INSTALLATION OF GAS FIRED HOT WATER BOILERS
B.S. 6891 1989 GAS INSTALLATIONS
B.S. 7671 1992 IEE WIRING REGULATIONS
B.S. 4814 1990 SPECIFICATION FOR EXPANSION VESSELS
B.S. 5482 1994 INSTALLATION OF LPG
Model Water Bye Laws
For Northern Ireland the rules in force apply


Produktspezifikationen

Marke: Ferroli
Kategorie: Zentralheizungskessel
Modell: Modena 80 E

Brauchst du Hilfe?

Wenn Sie Hilfe mit Ferroli Modena 80 E benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Zentralheizungskessel Ferroli

Bedienungsanleitung Zentralheizungskessel

Neueste Bedienungsanleitung fĂĽr -Kategorien-