Ferroli GN2 N Bedienungsanleitung
Ferroli
Zentralheizungskessel
GN2 N
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Ferroli GN2 N (44 Seiten) in der Kategorie Zentralheizungskessel. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/44
GN2 N
high-efficiency cast iron boiler for liquid fuels and/or gas
OPERATING, INSTALLATION AND MAINTENANCE INSTRUCTIONS
caldaia di ghisa ad alto rendimento per combustibili liquidi e/o gassosi
ISTRUZIONI PER LUSO LINSTALLAZIONE E LA MANUTENZIONE
chaudière en fonte a haut rendement pour combustibles liquides et/ou gazeux
INSTRUCTIONS POUR LINSTALLATION ET LENTRETIEN
caldera de fundición, de alto rendimiento para combustibles líquidos y/o gaseosos
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
verwarmingsketel in gietijzer met hoog rendement voor vloeibare en/of gasvormige brandstof
AANWIJZINGEN VOOR HET GEBRUIK, DE INSTALLATIE EN HET ONDERHOUD
IT
FR
ES
NL
TR
sivi ve/veya gaz yakitli yüksek ver‹ml‹
DÖKÜM DÖLMLÖ KAZAN
(1
co d. 35 4 1A581 - R ev. 0 3 - 0 4 /2 0 18
3541A581
EnglishItalianoFrançaisEspañol
Nederlands
Türkçe
2
GN2 N
Dear Customer,
Thank you for having chosen the GN2 N, an advanced-concept Ferroli boiler featuring cut-
ting-edge technology, high reliability and constructional quality. Carefully read this manual
and keep it for future reference.
The is a high-effi ciency heat generator for the production of hot water for heating GN2 N
purposes, suitable for operation with jet burners on gas or liquid fuel.
The boiler body consists of cast-iron elements, the shape of which, together with the careful
design of the fi ns, ensure high heat exchange effi ciency in all operating conditions.
Important warnings
• This manual provides important indications on the safety of
operation, installation and maintenance, and is an integral
and essential part of the product. Read this manual before
installation and operation. It should be carefully kept for future
reference.
• This appliance must only be used for the purposes it has been
specifi cally designed for. This appliance is used to heat water
to below-boiling temperatures at atmospheric pressure, and
must be connected to a heating and/or domestic hot water di-
stribution system, according to its characteristics, performance
and heating capacity. All other uses are considered improper
and thus dangerous.
• The appliance may not be opened nor its components tam-
pered with, except for the parts included in the maintenance
operations. The appliance may not be modifi ed to alter its
performance or use.
• The installation and maintenance operations must be perfor-
med according to the standards in force, the instructions of
the manufacturer and must be carried out by professionally
qualifi ed personnel.
• Incorrect installation or poor maintenance may cause damage
to people, animals or things. The manufacturer declines all
liability for damage deriving from errors in the installation and
operation of the appliance, and in any case from the failure to
observe the instructions provided.
• Before performing any cleaning or maintenance operations,
disconnect the appliance from the mains power supply using
the system switch and/or the corresponding on-off devices.
• In the event of faults and/or poor operation of the appliance, it
should be deactivated. Do not attempt to repair the appliance.
Contact professionally qualifi ed personnel only.
• After having removed the packaging, check that the contents
are intact. The parts of the packaging must not be left within the
reach of children, as they are potential sources of danger.
ENGLISH
Electrical power
supply
Max operating
pressure temperature
PIN
Serial number
Max operating
pressure
Heat output
Uselful heat output
Bar code
Water content
12/245
0085AS0420
0085
230V~50Hz IP X 0D
Ser. n. 0352L50349
Q
P
-
-
kW
kW
234,7
216
max
185
171
min
PMS
tmax
6
100
bar
°C
PMW
D
bar
l/min
Appr. nr.
H O2
105 L
THE MARKING CERTIFIES THAT THE PRODUCTS MEET THE ESSENTIAL REQUIREMENTS
OF THE RELEVANT DIRECTIVES IN FORCE.
THE DECLARATION OF CONFORMITY MAY BE REQUESTED FROM THE MANUFACTURER.
cod. 3541A581 - Rev. 03 - 04/2018
3
English Italiano Français Español
Nederlands
Türkçe
GN2 N
1. OPERATING INSTRUCTIONS
1.1 Control panel
1 2 3 4 5
1.2 Ignition
Move the main switch to position to power the boiler and the burner. Refer to the burner manual for the operation of this device. 5 “I”
1.3 Setting
Set the desired system temperature using the control thermostat . If the thermoregulation control unit (optional) is connected, refer to the 4
corresponding instruction manual.
1.4 Shut-down
For brief periods of inactivity, simply move switch (Fig. 1) on the control panel to position “0”. 5
For extended periods of inactivity, as well as operating switch , the fuel on-off valve must also be closed. 5
For extended periods of inactivity during the winter period, to avoid damage from frost, add special antifreeze to the system or drain the system
completely.
1.5 Anomalies
Two lockout conditions may occur that can be reset by the user:
a - Burner lockout signalled by the corresponding light 6 (Fig. 1). Refer to the burner manual.
b - Activation of the safety thermostat when the temperature in the boiler reaches the limit value above which a dangerous situation may arise.
To reset operation, unscrew cap and press the reset button. 3
If the problem occurs again, contact qualifi ed personnel or the service centre.
In the event of faults and/or poor operation of the appliance, it should be deactivated. Do not attempt to repair the appliance. Contact profes-
sionally qualifi ed and authorised personnel only.
2. INSTALLATION
General instructions
This appliance must only be used for the purposes it has been specifi cally designed for. This appliance is used to heat water to below-boiling
temperatures at atmospheric pressure, and must be connected to a heating and/or domestic hot water distribution system, according to its
characteristics, performance and heating capacity. All other uses are considered improper.
THE BOILER MUST ONLY BE INSTALLED BY QUALIFIED AND SPECIALIST PERSONNEL, IN COMPLETE COMPLIANCE WITH
ALL THE INSTRUCTIONS REPORTED IN THIS TECHNICAL MANUAL, THE LEGAL STANDARDS IN FORCE, THE PRESCRIP-
TIONS OF ANY NATIONAL AND LOCAL STANDARDS, AND ACCORDING TO THE RULES OF GOOD PRACTICE.
Incorrect installation may cause damage to people, animals and things. The manufacturer will not be held liable in such events.
Place of installation
The room in which the boiler is installed must have ventilation openings to the outside according to the standards in force. If the same room
features a series of burners or exhaust devices that can operate at the same time, the ventilation openings must be large enough for the
simultaneous operation of all the appliances.
The place of installation must be free of fl ammable objects or materials, corrosive gas, dust or volatile substances that, sucked in by the bur-
ner’s fan, may block the internal tubing of the burner or the combustion head. The environment must be dry and not exposed to rain, snow or
frost.
Positioning the boiler
The minimum spaces shown in the fi gure must be complied with. Specifi cally, make sure that after as-
sembling the boiler with the burner on the front door, the latter can be opened without the burner hitting
against the wall or any other boiler. Leave a free space of at least 100mm on the side that the door swings
towards.
6
100
mm
550==
Key
1 Ready for electronic control unit
2 Thermohydrometer
3 Safety thermostat
4 Control thermostat, 2 Stages
5 Line switch “0 - I - TEST”
6 Burner lockout indicator light
fi g. 1
fi g. 2
Burner
cod. 3541A581 - Rev. 03 - 04/2018
Produktspezifikationen
Marke: | Ferroli |
Kategorie: | Zentralheizungskessel |
Modell: | GN2 N |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Ferroli GN2 N benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Zentralheizungskessel Ferroli
5 Oktober 2024
2 September 2024
20 August 2024
10 August 2024
10 August 2024
2 August 2024
2 August 2024
31 Juli 2024
31 Juli 2024
29 Juli 2024
Bedienungsanleitung Zentralheizungskessel
- Zentralheizungskessel Bosch
- Zentralheizungskessel ATAG
- Zentralheizungskessel Inventum
- Zentralheizungskessel EAS Electric
- Zentralheizungskessel Vaillant
- Zentralheizungskessel Junkers
- Zentralheizungskessel De Dietrich
- Zentralheizungskessel Thermex
- Zentralheizungskessel Remeha
- Zentralheizungskessel Saunier Duval
- Zentralheizungskessel Stiebel Eltron
- Zentralheizungskessel Truma
- Zentralheizungskessel Viessmann
- Zentralheizungskessel Buderus
- Zentralheizungskessel Baxi
- Zentralheizungskessel Wolf
- Zentralheizungskessel Itho Daalderop
- Zentralheizungskessel Bulex
- Zentralheizungskessel Fantini Cosmi
- Zentralheizungskessel Roc
- Zentralheizungskessel Ariston Thermo
- Zentralheizungskessel La Nordica
- Zentralheizungskessel Intergas
- Zentralheizungskessel Mikoterm
- Zentralheizungskessel Nibe
- Zentralheizungskessel Elco
- Zentralheizungskessel Daalderop
- Zentralheizungskessel Itho
- Zentralheizungskessel Morco
- Zentralheizungskessel Nefit
- Zentralheizungskessel Oertli
- Zentralheizungskessel Thermona
- Zentralheizungskessel ACV
- Zentralheizungskessel Tzerra
- Zentralheizungskessel Weishaupt
- Zentralheizungskessel Ygnis
- Zentralheizungskessel Vokèra
- Zentralheizungskessel ETA Heiztechnik
- Zentralheizungskessel A.O. Smith
- Zentralheizungskessel AGPO
- Zentralheizungskessel Glow-worm
- Zentralheizungskessel Masterwatt
- Zentralheizungskessel Halstead
- Zentralheizungskessel AWB
- Zentralheizungskessel Ravenheat
- Zentralheizungskessel Brink
Neueste Bedienungsanleitung für -Kategorien-
15 Oktober 2024
15 Oktober 2024
14 Oktober 2024
13 Oktober 2024
10 Oktober 2024
8 Oktober 2024
8 Oktober 2024
7 Oktober 2024
7 Oktober 2024
5 Oktober 2024