User Guide
CCI Pro 700
TouchLink®
TouchLink Pro Conference Room Control Interface
68-2785-01 Rev. C
09 17
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di importanti istruzioni di funzionamento
e manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, gdy używany na produkt, ma na celu ,
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中
警告产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
有触电危险
注 意产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 网站 Extron , www.extron.com,参见
Extron 68-290-01 安全规范指南,产品编号
安全記事 • 繁體中文
警 告:產 品上 使用 此 符 號為了提 醒 使 用者,機 殼存 在
可能會導致觸電之風的未絕緣危險電壓。
注意 若產品使用此符號,是為了提醒使用者設備隨附的用戶手冊
重要的操作和維護(維修説明
有關安全性指導方針法規遵守EMI/EMF 相容性存取範圍和相關主題的詳細資
訊,請瀏覽 Extron 網站
www.extron.com然後參《Extron 安全性與法
守手冊準則編號 68-290-01
安全上のご注意 日本語
警告: この記号 品上に表示されている場合は体内に絶縁されて
いない高電圧がれ、感電危険があるとを示しいます
意:この記号 が製品上に表示されている場合はの取扱説明書
されている重要な作と保()指示についてユーザー
を喚起するものです
安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目に
ついては、エクロンのウブサイwww.extron.com Extron Safety
and Regulatory Compliance Guide P/N 68-290-01 ( ) をださい。
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
Copyright
© 2017 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks(®)
, registered service marks(SM)
, and trademarks(™) are the property of RGB Systems, Inc. or Extron
Electronics (see the current list of trademarks on the Terms of Use www.extron.com page at ):
Registered Trademarks (®)
Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, GlobalCongurator,
GlobalScripter, GlobalViewer, Hideaway, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA,
PlenumVault, PoleVault, PowerCage, PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, SystemINTEGRATOR, TeamWork,
TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and XTPSystems
Registered Service Mark
(SM) : S3 Service Support Solutions
Trademarks ()
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS (ClassD Ripple
Suppression), Codec Connect, DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), DriverCongurator,
DSPCongurator, DSVP (Digital Sync Validation Processing), eLink, Entwine, EQIP, EverLast, FastBite, FOX, FOXBOX, HyperLane,
IPIntercom HelpDesk, MAAP, MicroDigital, Opti-Torque, ProDSP, QS-FPC (QuickSwitch Front Panel Controller), Room Agent,
Scope-Trigger, ShareLink, Show Me, SIS, SimpleInstructionSet, Skew-Free, SpeedNav, StudioStation, Triple-Action Switching, True4K,
Vector 4K, WebShare, XTRA, ZipCaddy, and ZipClip
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause interference. This interference must be corrected at the
expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances,
EMI/EMF compatibility, accessibility, and related topics, see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.
Battery Notice
This product contains a battery. Do not open the unit to replace the battery. If the battery
needs replacing, return the entire unit to Extron (for the correct address, see the Extron
Warranty section on the last page of this guide).
CAUTION: Risk of explosion. Do not replace the battery with an incorrect type. Dispose
of used batteries according to the instructions.
ATTENTION : Risque d’explosion. Ne pas remplacer la pile par le mauvais type de pile.
Débarrassez-vous des piles usagées selon le mode d’emploi.
Conventions Used in this Guide
Notifications
The following notications are used in this guide:
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.
Software Commands
Commands are written in the fonts shown here:
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character ” is used for the number zero and “ ” is the capital
letter “ .”
Computer responses and directory paths that do not have variables are written in the
font shown here:
Variables are written in slanted form as shown here:
Selectable items, such as menu names, menu options, buttons, tabs, and eld names
are written in the font shown here:
From the menu, select .
Click the button.
Specifications Availability
Product specications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Contents vii
Contents Contents
Configuration Software .............................. 18
Configuration Software Programs 18 .....................
Software Descriptions 18 ...................................
Software Overview 19 ........................................
Software Download 19 ......................................
Software Installation 20 ......................................
Internal Web Page 20 ............................................
Web Page Access 20 ........................................
License Information 21 ......................................
Firmware Updates 21 ........................................
Reference Information ............................... 22
Mounting 22 ..........................................................
Network Port Requirements.............................. 22
Button Replacement 22 .........................................
Reset Modes 24 ....................................................
Firmware Download 25 ..........................................
Introduction ................................................... 1
Guide Overview 1 ..................................................
Product Description 1 ............................................
Features 1 .............................................................
Application Diagram 2 ...........................................
Installation Overview .................................... 3
Panel Features .............................................. 5
Front Panel Features 5 ...........................................
Rear Panel Features 6 ...........................................
Rear Panel Access 6 .........................................
Rear Panel Buttons and Connector 7 ................
Cable Routing 10 ...............................................
Setup Menu.................................................. 11
Navigation and Data Entry 11 ................................
Setup Menu System 12 .........................................
Status Submenu 12 ...........................................
Network Submenu 13 ........................................
Display Submenu.......................................... 14
Audio Submenu 15 ............................................
Advanced Submenu 16 .....................................
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Contents viii
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Introduction 1
Introduction
This section contains basic information about the Extron CCI Pro 700 TouchLink Pro
Conference Room Control Interface. Topics in this section include:
Guide Overview
Product Description
Features
Application Diagram
Guide Overview
This guide contains information about installing, operating, and configuring the CCI Pro 700
TouchLink Pro Conference Room Control Interface. In this guide, the terms “CCI Pro 700”
and “interface” refer to the CCI Pro 700 TouchLink Pro Conference Room Control Interface.
Product Description
The CCI Pro 700 is control system user interface optimized for conferences, collaboration,
and AV control. It supports many critical functions needed in a conference environment,
while providing a powerful and intuitive user interface for room control. The compact
CCI Pro 700 includes a 3.5 inch color information display, a numeric keypad, and backlit
buttons. The information display is customized using GUI Designer, and all buttons can be
configured and customized using Global Configurator Plus and Professional, and Custom
Button Builder.
Features
Fully configurable — Controls conference systems and AV devices from a single
interface.
Audio, video, and Web integration — Works seamlessly with virtually any audio,
video, or Web conference solution.
IP Link Pro control processor compatibility — Directly communicates with any
IP Link Pro control processor via Ethernet.
Customizable 3.5 inch color information display with context-dependent
buttons — Displays contact information, dialing directories, and call status.
Six customizable function buttons — Control AV devices or call presets. Buttons
are included with labels for display on, display off, and source selection. Create custom
labels and order custom buttons by using Custom Button Builder.
Dual color call status indicator — Shows various conference room conditions such
as microphone mute, privacy, or an incoming call.
Configurable buttons — Control critical conference functions. These backlit buttons
for volume, navigation, call mode, keypad, and room and conference functions are
grouped for easy user operation of the conference environment.
Power over Ethernet (PoE) — Allows the interface to receive power and control over
a single Ethernet cable, eliminating the need for a local power supply (PoE injector sold
separately).
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Introduction 2
Light sensorAdjusts screen and button brightness as the ambient room lighting
changes.
Adjustable sleep timer — Puts the interface into Sleep mode to save energy when
not in use.
Motion detector — Wakes the interface from Sleep mode when motion is detected
near the interface.
Extron control system software — Fully configures the interface. GUI Designer
configures the LCD screen layout. Global Configurator Plus and Professional configure
the button functions.
Support for Extron Control App and Extron Control for Web
Pull-out tray — Provides easy access to reminders or system information, such as
contact numbers or system presets.
Section 508 compliance — Meets or exceeds Section 508 accessibility standards.
Application Diagram
AXP 50 C AT
RESET
1
2 3 4 5
1
IN G
POWER
12V
1.0A MAX
0102 IN G 01 02 IN G 0 1 02 IN G 0102 IN G 010 2
2 3 4 5
234
I/OINPUTS
AT
1
100-24 0V ~ 0.7A MAX
50/60 Hz LANEXP
RS-23 2
Tx Rx G
RESET
MIC +4 8V
5 6 7 8
1 2 3 4 8
4 1
1 2 3 4 5 G 6
1234
7 8 9 G10
11 12 13 14 15 1617 18 19 20G G
2 3 4
5 6 7 8
9 10
11 127
3
6
2
5
1
MIC/LINE INPUTS
OUTPUTS
DIGITAL I/O
REMOTE AT
DMP 128 C AT
100-240V 0.5 A, 5 0-60 Hz XPA 2001-70V
LIMITER/PROTECT
SIGNAL 0
2
4
6
81012
18
14
26
ATTENUA TION H PF 70 V OUTPUT
REMOTE
INPUTS
CLASS 2 WIRING
G
GCV
L
(SUMMED)
R
10V
80 Hz
OFF
50mA
STANDBY
100-240V 0.5 A, 5 0-60 Hz XPA 2001-70V
LIMITER/PROTECT
SIGNAL 0
2
4
6
81012
18
14
26
ATTENUA TION H PF 70 V OUTPUT
REMOTE
INPUTS
CLASS 2 WIRING
G
GCV
L
(SUMMED)
R
10V
80 Hz
OFF
50mA
STANDBY
100-240V 0.5 A, 5 0-60 Hz XPA 2001-70V
LIMITER/PROTECT
SIGNAL 0
2
4
6
81012
18
14
26
ATTENUA TION H PF 70 V OUTPUT
REMOTE
INPUTS
CLASS 2 WIRING
G
GCV
L
(SUMMED)
R
10V
80 Hz
OFF
50mA
STANDBY
100-240V 0.5 A, 5 0-60 Hz XPA 2001-70V
LIMITER/PROTECT
SIGNAL 0
2
4
6
81012
18
14
26
ATTENUA TION H PF 70 V OUTPUT
REMOTE
INPUTS
CLASS 2 WIRING
G
GCV
L
(SUMMED)
R
10V
80 Hz
OFF
50mA
STANDBY
100-240V 0.5 A, 5 0-60 Hz XPA 2001-70V
LIMITER/PROTECT
SIGNAL 0
2
4
6
81012
18
14
26
ATTENUA TION H PF 70 V OUTPUT
REMOTE
INPUTS
CLASS 2 WIRING
G
GCV
L
(SUMMED)
R
10V
80 Hz
OFF
50mA
STANDBY
LANLAN
POWER
12V
0.7A MAX
Rx GTx
RS-232 IR
XTP R HDMI
RL
RxTx
-+ -+-+
1 2
AUDIO
ON
AUDIO
RESET
LAN
OVER XTP OUTPUTS RELAYS
SIG LINK
XTP IN HDMI
OFF
S/ PDIF
POWER
12V
0.7A MAX
Rx GTx
RS-232 IR
XTP R HDMI
RL
RxTx
-+ -+-+
1 2
AUDIO
ON
AUDIO
RESET
LAN
OVER XTP OUTPUTS RELAYS
SIG LINK
XTP IN HDMI
OFF
S/ PDIF
eBUS
FLEX I/ORELAYSIR/SERIALCOM12 VDC
LAN
+VTxRx Tx Rx TxRx Tx Rx G G G G S G S G S G S GRTSCTS
+ - + -
+ - + - -S G
PW R OUT = 12 W
+S
S G S G S G S GTxRx Tx Rx TxRx Tx RxG G G G RTSCTS
1 2 3 4 G
1 2 3 4
5 6 7 8
1 1 2 3 4
5 6 7 8
2 3 7
4 5 6 8
1 2
3
100-240V ~ 50-60Hz
5A MAX
SWITCHED 12 VDC
40W MAX TOTAL
4
IPCP PRO 550
AUDIO
PRIMARY
REDUNDANT
VIDEO
I/O
POWER
CONTROL
ENTER PRESET VIEW ESC
INPUTS
OUTPUTS
1 2 3 4 5 6 7 8 9 10 11 12 14 15 1613
1 2 3 4 5 6 7 8 9 10 11 12 14 15 1613
XTP CROSS POINT 1600
XTP SERIES DIGITAL MATRIX S WITCHER
CONFIG
STANDB Y /ON
PQLS HDMI OPEN/CLOS E FL O FF
USB
PUSH PUSH
POWER MEN U RESGUIDE 480 480p720p 1080i 1080p DIRECT V H D
SELECT
DIRECTV
1
_,@
4
GHI
7
PQRS
*
3
DEF
6
MNO
9
WXYZ
#
2
ABC
5
JKL
8
TVU
0
OPER
DVD / VH S
AUTO I MAGE
TV
MP 3
REC EI VER
HEL P
FLASH
REDIAL
1
_,@
4
GHI
7
PQRS
*
3
DEF
6
MNO
9
WXYZ
#
2
ABC
5
JKL
8
TVU
0
OPER
DVD / VH S
AUTO I MAGE
TV
MP 3
REC EI VER
HEL P
FLASH
REDIAL
Dante
Net work
Extron
XPA 2001-70V
Power Ampliers
Extron
SI 3CT LP
Full-Range
Speakers
Extron
DMP 128 C AT
Digital Matrix
Processor
Wireless
Microphones
Blu-ray Player
Satellite Receiver
Extron
XTP CrossPoint 1600
Modular Digital Matrix
Switcher
Cameras
Video
Conference
Codec
Extron
XTP R HDMI
Receiver
Extron
XTP R HDMI
Receiver
Projector
Projector
RS-232
RS-232
IR
IR
RS-232
Ethernet Ethernet
Ethernet
Ext ron
IPCP Pro 550
IP Link Pro Control
Processor
Ext ron
TLP Pro 1220TG
12" Tabletop
TouchLink Pro
Touchpanel
Extron
CCI Pro 700
TouchLink Pro
Conference Room
Control Interface
Document
Camera
TCP/IP
Network
Extron
AXP 50 C AT
Audio Expansion Processor
(Audio Expansion Typical of 5)
Table Microphones with Mute and Light Control
Digital I/O Control
Figure 1. Typical Application Diagram
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Installation 3
Installation Overview
This section contains basic installation procedures.
1. Before starting, download (www.extron.com) and install the latest versions of the
following software:
Global Configurator Plus and Professional (GC) — For configuring button
actions and functions of the interface.
NOTES:
Global Configurator Plus and Professional operates in either Plus mode or
Professional mode.
Global Configurator Professional access requires Extron Control
Professional certification.
Global Scripter (GS) — This is an alternative to Global Configurator Plus and
Professional for programming the button actions and functions of the interface.
GUI Designer — For designing or adjusting LCD screen layouts.
You might also want to download a customized system template. Extron has created a
number of system templates, available for free from the CCI Pro 700 product page on
the Extron website. Each template is customized for use with a specific model of audio
or video conferencing codec. It includes the driver for the codec, a GUI layout template
for the CCI Pro 700, and configurations for the buttons and screen.
2. Obtain the following network information from your network administrator:
DHCP status (on or off) — If DHCP is off, obtain the following:
IP address
Subnet mask
Gateway
3. Mount and cable the units:
a. Mount the unit on a flat surface (see Mounting on page22).
b. Remove the CCI Pro 700 from the base to access the rear panel (see Rear Panel
Access on page6).
c. Route an Ethernet cable through the opening in the base (see Cable Routing on
page10).
d. Connect an Ethernet cable from the network to the interface (see Rear Panel
Buttons and Connector on page7).
NOTE: If necessary, use a power injector along the Ethernet cable run to apply
power.
e. Attach the base to the rear panel of the interface.
4. Use the setup menu to initially set up the interface (see Setup Menu on page11).
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Installation 4
5. If using Global Configurator Plus and Professional to set up the system, either:
Download a GC system template project (as mentioned in step 1), start Global
Configurator, open the template project, and configure the rest of the system as
desired. The embedded GUI layout can be exported, modified in GUI Designer, then
imported back into the GC project.
or
Create a layout for the interface using GUI Designer. Start a project in Global
Configurator. Import the GUI layout to the project and use GC to configure the
interface.
6. If using Global Scripter to set up the system, create a layout for the interface using
GUI Designer then start Global Scripter. Import the GUI layout, program the control
processor and interface, and program button functions.
7. Save the GC project or GS script file.
8. Upload Global Configurator or Global Scripter files to the CCIPro700 interface.
9. Test the system to verify that the button actions and LCD screen are working as
configured.
10. Make adjustments to the configuration or programming if needed and upload the
revised file to the interface.
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Panel Features 5
Panel Features
This section contains enclosure features. Topics in this section include:
Front Panel Features
Rear Panel Features
Front Panel Features
The CCI Pro 700 comes with installed buttons for common functions (see Button Replacement
on page22 for information on changing the buttons). However, button functions are
not assigned until configured in Global Configurator Plus and Professional (see the Global
Configurator Help file). See figure 2 for front panel features and common button functions.
DEF
3
MNO
6
WXYZ
9
#
*
ABC
2
JKL
5
TUV
8
OPER
0
PQRS
7
GHI
4
1
FLASH
REDIAL
A
B
D
E
F
G
H
I
J
L
N
M
C
K
A (see below)
LCD screen
B Volume button (see below)
C (see below)
Ambient light sensor
D (see below)
Context buttons
E (see below)
Optional buttons
F (see page 6)
Dial buttons
G (see page 6)
Mic mute button
H (see page 6)
Number keypad buttons
I (see page 6)
Navigation buttons
J Transmit LED indicator (see page 6)
K (see page 6)
Function buttons
L (see page 6)
Motion sensor
M (see page 6)
Pull-out tray
N (see page 6)
Status indicator
Figure 2. Front Panel Features
A — A 320x240, 3.5 inch diagonal color screen.LCD screen
B Volume button — Controls volume.
C — Detects room lighting changes and adjusts button and Ambient light sensor
screen illumination levels accordingly.
D — Select specific options on the bottom of the LCD screen or in the Context buttons
setup menu.
E — Can be configured for any included button label.Optional buttons
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Panel Features 6
F — Start or end conference calls (see Dial buttons figure 2, F on the previous page).
G — Mutes or unmutes conference room microphones (see Mic mute button G on the
previous page).
H — Consist of alphanumeric characters for dialing phone Number keypad buttons
numbers or entering values (see H).
I — Navigate the setup menu, on-screen menus, and lists created Navigation buttons
in the GUI. These buttons include the ( ), ( ), ( ), and ) > < ◄ (►
buttons as well as the ] button (see I).
J Transmit LED indicator — Lights according to function button activity (see J).
K — Select inputs or other configurable functions (see Function buttons K).
L — Detects motion and wakes the panel from Sleep mode (see Motion sensor L).
M — Houses important information (see Pull-out tray M).
N — Lights green or red for various conference call conditions, such as Status indicator
active conference calls or a muted microphone (see N).
Rear Panel Features
Rear Panel Access
To access the rear panel, remove the CCI Pro 700 from the base as follows:
1. Firmly hold the base and lift up the tab on the top of the CCI Pro 700 to dislodge the
CCI Pro 700 from the base.
Base
Interface
Figure 3. Pulling the Tab
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Panel Features 7
2. Carefully lift the CCI Pro 700 away from the base.
Figure 4. Removing the CCI Pro 700 From the Base
Rear Panel Buttons and Connector
Remove the device from the base to access the rear panel features (see Rear Panel
Access on the previous page).
MENU RESET
ABC
A (see below)LAN and Power over Ethernet (PoE) connector
B (see page 9)
Menu button
C (see page 9)
Reset button and LED
Figure 5. Rear Panel Features
A — Connect a twisted pair cable to LAN and Power over Ethernet (PoE) connector
this RJ-45 connector (see figure 5, A above). The Ethernet cable can be terminated as
a straight-through cable or a crossover cable (see figure 6 on the next page).
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Panel Features 8
12345678
RJ-45 Connector
Insert T
wisted
Pair Wires
Pins:
Side View
Straight-through Cable
End 1 End 2
Pin Wire Color Pin Wire Color
1 white-orange 1 white-orange
2 orange 2 orange
3 white-green 3 white-green
4 blue 4 blue
5 white-blue 5 white-blue
6 green 6 green
7 white-brown 7 white-brown
8 brown 8 brown
Crossover Cable
End 1 End 2
Pin Wire Color Pin Wire Color
1 white-orange 1 white-green
2 orange 2 green
3 white-green 3 white-orange
4 blue 4 blue
5 white-blue 5 white-blue
6 green 6 orange
7 white-brown 7 white-brown
8 brown 8 brown
Figure 6. RJ-45 Connector Pinout Tables
Plug one end of the cable into the RJ-45 connector and the other end into a network
switch, hub, or router that is connected to an Ethernet LAN or the Internet. An Extron
IPLinkPro control processor must also be connected to the same network domain.
The network port has two LEDs. The green LED lights when a network connection is
established. The yellow LED blinks when data is passed to or from the interface.
ATTENTION: The CCI Pro 700 is Power over Ethernet (PoE IEEE 802.1af, class 3)
compliant. Do not connect power before reading the Attention notification on
page 9.
ATTENTION : Le CCI Pro 700 est compatible avec l’alimentation POE via Ethernet
(PoE 802.3af, classe 3). Ne branchez pas de sources d’alimentation externes
avant d’avoir lu les mises en garde sur .
page 9
NOTE: Power over Ethernet is required to power the device.
To use a power injector, connect a straight-through Ethernet cable to the power supply
and a switch or router. This cable carries network information from the switch or router
to the power injector input. Connect a second straight-through cable between the
power injector and the CCI Pro 700 to carry the network information and 48VDC from
the power injector to the interface. Connect the IEC power cord to a convenient
100 VAC to 240 VAC, 50-60 Hz power source.
Figure 7 below shows the Extron XTP PI 100. Your power injector may look different.
100-240V
~
50-60 Hz
0.4A MAX
XTP
PWR
XTP PWR
To a
network switch
To the
CCI Pro 700
Figure 7. Connecting the Power Injector
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Panel Features 9
ATTENTION:
The CCI Pro 700 is intended for connection to a Power over Ethernet circuit for
intra-building use only and are considered to be part of a Network Environment
0 per IEC TR62101.
Le CCI Pro 700 est conçu pour une connexion à un circuit PoE pour une
utilisation intérieure seulement et est considéré comme faisant partie d’un
environnement réseau 0 par IECTR62101.
This product is intended for use with a UL Listed power source marked
“Class 2” or “LPS” and rated 48 VDC (PoE), minimum 0.35 A.
Ce produit est destiné à une utilisation avec une source d’alimentation listéeUL
avec l’appellation «Classe2» ou «LPS» et normée 48Vcc (PoE), 0,35A
minimum.
Power over Ethernet (PoE) is intended for indoor use only. It is to be connected
only to networks or circuits that are not routed to the outside plant or building.
L’alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur
uniquement. Elle doit être connectée seulement à des réseaux ou des circuits
qui ne sont pas routés au réseau ou au bâtiment extérieur.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16.
Cette installation doit toujours être en accord avec les mesures qui s’applique
au National Electrical Code ANSI/NFPA70, article725, et au Canadian
Electrical Code, partie1, section16.
The power supply shall not be permanently fixed to building structure or similar
structure.
La source d’alimentation ne devra pas être fixée de façon permanente à une
structure de bâtiment ou à une structure similaire.
B — Press this button (see Menu button figure 5, B on page 7) to open the setup
menu on the LCD screen (see on page11). To access the recessed
Setup Menu
button, use an Extron Tweeker or small screwdriver.
C — Press this button (see Reset button and LED figure 5, C on page 7) to reset
the CCI Pro 700 (see on page24). To access the recessed button,
Reset Modes
use an Extron Tweeker or small screwdriver.
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Panel Features 10
Cable Routing
1. Remove the CCI Pro 700 from the base (see on page6).Rear Panel Access
2. Pull the twisted pair cable through the opening at the bottom of the base (see figure 8).
Figure 8. Routing Cable through the Base Opening
3. Connect the cable to the LAN and PoE connector (see figure 5, A on page 7)
4. Route the cable around the guides of the CCI Pro 700 as shown in figure 9, below.
Figure 9. Routing Cable along the Rear Panel
5. Reattach the CCI Pro 700 to the base.
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Setup Menu 11
Setup Menu
This section contains basic setup information using the setup menu system. Topics in this
section include:
Navigation and Data Entry
Setup Menu System
Navigation and Data Entry
Menu button — Press the button (see figure 5, B on page 7) to access or
exit the setup menu.
Directional Navigation buttons — Press the (>), (<), ( ), and
( ) buttons (see ,
figure 2 I on page 5) to move between
elements on the LCD screen. When editing text, press the and buttons
to move the cursor. When adjusting numeric values, press the and buttons
to increase or decrease the value by one step respectively. Pressing and holding either
button changes the values at an increased rate.
] ] Navigation button — Press the button (see figure 2, I) to
select an item.
Context buttons — Press the context button (see figure 2, C) directly below
options displayed in the bottom menu of the LCD screen (see figure 2, A) to perform
additional actions.
Keypad — Press the alphanumeric keypad buttons (see figure 2, H) to set values.
Numbers or letters can be entered depending on the fields. To enter numeric values,
press the desired number keypad button.
NOTE: If letters or numbers can be entered into the same field, pressing the same
keypad button multiple times in succession changes a number to a letter. To enter
the same number multiple times in a row, pause between button presses.
To enter letters, note the groups of letters on the keypad buttons and press the button
repeatedly until the desired letter appears on the LCD screen.
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Setup Menu 12
Setup Menu System
The setup menu contains four submenus for configuring the CCI Pro 700 and one to display
information about the CCI Pro 700. The available submenus include:
Status Submenu
Network Submenu
Display Submenu
Audio Submenu
Advanced Submenu
To navigate between submenus, press the > or < button to highlight a
submenu and press the button to select it.]
Status Submenu
This submenu (see figure 10) displays basic information about the CCI Pro 700 and is read-
only. By default, pressing the button on the rear panel displays this submenu first.
Model — Displays the model name
of the interface.
Part number — Displays the part
number of the interface.
Firmware version — Displays the
current firmware version.
Power over Ethernet status
Displays the status of the power
over Ethernet connection.
Figure 10. Status Submenu
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Setup Menu 13
Network Submenu
This submenu (see figures 11 and 12) contains options to configure network settings.
Network settings can be assigned automatically with Dynamic Host Configuration Protocol
(DHCP) or manually by specifying an IP address, subnet mask, gateway address, and
Domain Name Server (DNS) IP address obtained from the network administrator. To finalize
pending changes, press the button directly below . To cancel pending
changes, click the button directly below .
Figure 11. Network Submenu — Page 1
DHCP — Press the or button to enable or disable dynamic host ◄ ►
configuration protocol (DHCP) (the default is disabled). When enabled, only the host
name can be changed.
Host name — If DHCP mode is enabled, press the button to edit ]
the host name (63 character maximum). Use the and buttons to ◄ ►
move the cursor position and the to enter values.
NOTE: Use the button to enter a dash ( ) character.
IP address — Press the button to edit the IP address. Use the ]
and buttons to move the cursor position and the to enter
values. The range is to 255.255.255.255 (the default is 192.168.254.251).
NOTE: Use the button to enter a period ( ) character.
Subnet mask — Press the button to edit the subnet mask. Use the ]
◄ ► and buttons to move the cursor position and the to enter
values. The range is to 255.255.255.255 (the default is 255.255.255. ).
NOTE: Use the button to enter a period ( ) character.
Gateway address — Press the button to edit the gateway address. ]
Use the and buttons to move the cursor position and the ◄ ►
to enter values. The range is to 255.255.255.255 (the default is ).
NOTE: Use the button to enter a period ( ) character.
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Setup Menu 14
Figure 12. Network Submenu — Page 2
DNS (IP) — Press the button to edit the DNS address. Use the ]
◄ ► and buttons to move the cursor position and the to enter
values. The range is to (the default is ).
Domain name — Displays the domain name.
MAC address — Displays the MAC hardware address of the interface.
Display Submenu
This submenu (see figure 13) contains settings to adjust the display and sleep timer.
Figure 13. Display Submenu
Auto brightness mode — Press the or button to enable or ◄ ►
disable the auto brightness feature. When enabled, the LCD screen and button
illumination levels are automatically adjusted to the amount of ambient room light.
Brightness level — Press the and buttons to select the brightness ◄ ►
level of the LCD screen. When this is set, the auto brightness feature is disabled.
Sleep timer mode — Press the or button to enable or disable ◄ ►
sleep mode. Sleep mode activates after a certain amount of time of inactivity passes.
The time is determined by the sleep timeout setting.
To deactivate Sleep mode after it has been activated, perform one of the following:
Press a button on the front panel.
With wake on motion mode enabled, make a motion near the device.
Sleep timeout period — Press the and buttons to select the ◄ ►
period of inactivity (in minutes) required to activate sleep mode.


Produktspezifikationen

Marke: Extron
Kategorie: Videokonferenzsystem
Modell: CCI Pro 700
Touchscreen: Ja
Bildschirmdiagonale: 3.5 "
Breite: 201 mm
Tiefe: 173 mm
Gewicht: 1100 g
Produkttyp: Multipoint Control Unit (MCU)
Produktfarbe: Schwarz
Höhe: 89 mm
Eingebautes Display: Ja
Betriebstemperatur: 0 - 50 °C
Relative Luftfeuchtigkeit in Betrieb: 10 - 90 %
Verpackungsbreite: 279 mm
Verpackungstiefe: 140 mm
Verpackungshöhe: 279 mm
Paketgewicht: 1470 g
Unterstützte Netzwerkprotokolle: DHCP, DNS, HTTP, HTTPS, ICMP, SFTP, SSH, TCP/IP, UDP/IP
Zertifizierung: CE, c-UL, UL, C-tick, FCC A, ICES, VCCI
Display: LED
Stromverbrauch (Standardbetrieb): 10.7 W
Anzahl Ethernet-LAN-Anschlüsse (RJ-45): 1
Kontrastverhältnis: 350:1
Ethernet LAN Datentransferraten: 10, 100 Mbit/s
Temperaturbereich bei Lagerung: -20 - 60 °C
Luftfeuchtigkeit bei Lagerung: 10 - 90 %
Megapixel (ca.): - MP
Größe des Bildsensors: - "
Anzahl der Personen: - Person(en)
Speicherkapazität: 512 MB
Gesamtspeicherkapazität: 0.5 GB
Speichermedien Typ: Flash
Display-Auflösung: 320 x 240 Pixel
Ethernet/LAN: Ja

Brauchst du Hilfe?

Wenn Sie Hilfe mit Extron CCI Pro 700 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Videokonferenzsystem Extron

Bedienungsanleitung Videokonferenzsystem

Neueste Bedienungsanleitung für -Kategorien-