LD-10 MAINTENANCE INSTRUCTIONS
ALL RIGHTS TO DESIGN AND/OR INVENTION ARE RESERVED BY EX-CELL KAISER LLC
ITEM NO.
PART NUMBER
DESCRIPTION
QTY.
4
45-LD-001
Sink: 10.75 d x 4.5 deep
1
6
45-LD-002
Tank: Vertical Closed Head w/ 8" lid
1
14
45-LD-004
Drain: 1-1/4" 304 SS
1
15
45-LD-002L
Storage Tank Lid
1
17
45-LD-009
Pipe to Tank Seal
1
23
45-LD-004A
Drain Nut
1
24
45-LD-004B
4" SS Tail Piece
1
25
3185K115
Locknut
1
26
45-LD-011
12" PVC Tail Piece
1
28
45-LD-010
Vinyl Tubing
1
29
5237T22
Coupler: 3/4" coupler x 3/4" Hose
1
Swivel wheels
Rigid Wheels
Lay the unit on its side and attach the
4 casters with the 16-- 1/4-20 hex bolts.
2 rigid wheels to the front and
2 swivel wheels to the back.
3.25
+
-
.25
.25
From bottom of drain lock
nut to top of 12" PVC tailpiece
4
15
6
26
24
23
17
PLEASE READ CAREFULLY BEFORE PUTTING INTO SERVICE
After unpacking and assembling the wheels, verify that the plumbing fittings
have not moved during shipment.
The dimension from the drain locknut to the top of the PVC tail
piece should be no more than 3-1/2".
If the fittings have moved during shipment, perform a leak test before putting the unit in service. If the PVC
tailpiece has slipped, and is
leaking, loosen the white PVC lock nut -- -- and loosen the black cover -- 26 15
--
for the storage tank. Push the white
PVC tailpiece up until it firmly seats against the SS tail piece --
24 -- and
retighten using a channel locks or wrench.
If you need to pull the storage tank
cover down to retighten, a few drops of
WD-40 around the PVC tailpiece
at the seal --
17 -- will allow it to move and you will be able to pull the storage cover down to screw it back
into place on the storage tank.
To Drain the Retention Tank
1) Connect the Lock coupler with the
Vinyl hose to the fitting at the ball
valve.
2) After fitting is locked in place
open the valve as shown
To Clean the Retention Tank
1) Turn the retention tank cover
counterclockwise to loosen
2) Lift the entire sink/drain pipe
assembly off the retention tank
3) Slide tank out of the cabinet and
clean