Entes MPR-60S-41 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Entes MPR-60S-41 (39 Seiten) in der Kategorie niet gecategoriseerd. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/39
A : onsult the operating instructions before using the equipment.TTENTION C
If these precautions are not properly observed and carried out, it can cause physical accident
or damage to the equipment or the installation.
The manufacturer or the authorized seller is not responsible for the consequences
resulting from failure to comply with these precautions.
SAFETY PRECAUTIONS
This equipment has been manufactured and tested and it has left the factory in perfectly safe condition.
To preserve this and ensure safe operation of the equipment the user should comply with the instructions
which are mentioned in this manual.
Before installing, check that the operating and network voltages are the same!
Before carrying out any work on the equipment, check that it is disconnected from the electrical supply.
If the equipment is no longer completely safe to use, it should be taken out of service and
protected against any accidental use.
Operator Safety
Read the following recommendations carefully before installing and operating the equipment.
The equipment described in this manual is designed only to be used by trained personnel.
Maintenance work must be carried out only by qualified, authorised personnel.
Personnel must observe the usual safety procedures for safe operation and during any maintenance work.
Breakdown Precautions
If you suspect that the equipment may no longer be safe (e.g. because of transport or operational damage),
it must be taken out of service and protected against any accidental use.
The equipment should be handed over to authorised technicians for checking.
Cleaning Instructions
Disconnect the equipment from the electrical supply and only use a damp cloth to clean the external surfaces.
Do not use any abrasive materials or solvents. Do not allow any moisture to reach the connection terminals.
1
MPR60S/MPR60S-10/20/21/40/41
NETWORK ANALYSER A2922b
ver.1.78
Important note for system connection
indicators indicate the existence of the three phases. (See Figure 1)
If is seen, you have to change any of the 2 phases beforeindicator (Phase sequence is not correct)
proceeding. (L1 - L2, L2 - L3 or L1 - L3)
Figure 1: The existence of three phases on LCD.
Standards which are applied to the device:
EN 61000-6-2, EN 61000-6-4, EN 55016-2-1, EN 55016-2-3, EN 55011, EN 61000-3-2, EN 61000-3-3, EN 61010-1
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
SUMMARY
SAFETY PRECAUTIONS..........................................................................................................................1
IMPORTANT NOTE FOR SYSTEM CONNECTION.........................................................................1
1. DESCRIPTION..........................................................................................................................................3
1.1 Introduction...........................................................................................................................................3
1.2 The front panel.......................................................................................................................................4
1.3 Front panel properties...........................................................................................................................5
1.4 The rear panel.......................................................................................................................................6
2. INSTALLATION........................................................................................................................................7
2.1 Mechanical assembly..........................................................................................................................7
2.2 Operating conditions............................................................................................................................7
2.3 Electrical connection.............................................................................................................................8
2.4 PC Connection.....................................................................................................................................9
3. MODBUS RTU PROTOCOL................................................................................................................10
3.1 Modbus functions................................................................................................................................10
3.2 Features of connection cable..............................................................................................................11
3.3 I/O Relay Status Register.........................................................................................................................11
3.4 Learning of device informations(2BH).................................................................................................11
3.5 Reading and writing to data logs from device (14H)...........................................................................11
3.6 File record information table...............................................................................................................11
3.7 Energy log table..................................................................................................................................12
3.8 Error codes.........................................................................................................................................12
3.9 MPR-SW (Interface Program).............................................................................................................12
3.10 Data register map (16 bit)..........................................................................................................................13
3.11 Data register map (32 bit).........................................................................................................................14
3.12 Setup register map (16 bit) .........................................................................................................(MPR60S) 15
3.13 Setup register map (16 bit) (MPR60S-10) 16 .......................................................................................................
3.14 Setup register map (16 bit) (MPR60S-20) 17 ......................................................................................................
3.15 Setup register map (16 bit) (MPR60S-21) 18 ......................................................................................................
3.16 Setup register map (16 bit) (MPR60S-40) 19 ........................................................................................................
3.17 Setup register map (16 bit) ........................................................................................................(MPR60S )-41 20
4. GENERAL MENU.....................................................................................................................................21
4.1 Setup..................................................................................................................................................21
4.2 Network...............................................................................................................................................21
4.3 Setting the date and time....................................................................................................................22
4.4 PC Communication Settings (RS-485).................................................................................................22
4.5 Datalog.................................................................................................................................................23
4.6 Output Relays and Digital Outputs (Relay 1 and Relay 2)...............................................................................24
4.7 Pulse Outputs (Pulse A and Pulse R) (MPR60S/MPR60S-21/41) 27...................................................................
4.8 Digital Inputs (3. Input-1 / 4. Input-2) ........................................................................(MPR60S ) -10/20/40 29
4.9 Display.................................................................................................................................................30
4.10 Instantaneous Values..........................................................................................................................30
4.11 Energy.................................................................................................................................................33
4.12 Demand..............................................................................................................................................35
4.13 Observing the time and date...............................................................................................................38
4.14 Info.......................................................................................................................................................40
4.15 Manufacturer-Product Information.........................................................................................................41
4.16 Password.............................................................................................................................................42
4.17 Parameter Table..................................................................................................................................43
4.18 Formulas..............................................................................................................................................43
4.19 Current Analog Output (0/4-20mA) (MPR60S-40/41) 44.....................................................................................
4.20 Voltage Analog Output (0/2-10V) .....................................................................................(MPR60S ) -20/21 45
4.21 Factory Settings......................................................................................................................................46
4.22 Technical Data.....................................................................................................................................47
5. STANDART AND EXPLANATIONS..............................................................................................48
2
1. DESCRIPTION
Figure 2: General view of the device.
3
1.1 INTRODUCTION
Device is a network analyser in 96x96 mm dimension with a non-flammable enclosure. It is designed for
measuring all electrical parameters of an electric network with MODBUS-RTU Protocol on RS-485 communication
port in order to communicate with the computer.
Device, based on DSP (Digital Signal Processor), is designed for the purpose of measuring all parameters in industry
plants and recording these parameters to its memory. The measured parameters can be displayed on LCD screen
which has dimension of 3.6 inch and can be read easily in dark environments by activating the Back-Light function.
Device contains a MODBUS serial interface option.

Produktspezifikationen

Marke: Entes
Kategorie: niet gecategoriseerd
Modell: MPR-60S-41

Brauchst du Hilfe?

Wenn Sie Hilfe mit Entes MPR-60S-41 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung niet gecategoriseerd Entes

Bedienungsanleitung niet gecategoriseerd

Neueste Bedienungsanleitung für -Kategorien-