Entes MCB-7 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Entes MCB-7 (2 Seiten) in der Kategorie niet gecategoriseerd. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
100
8
64
2
Teknik Bilgi
Ýþletme Gerilimi (Un) : 220 VAC, 230 VAC, 240 VAC, 24 VAC/DC
(115,127 V AC ve12 VAC/DC istek üzerine yapýlýr.)
Ýþletme Aralýðý : (0.9-1.1) x Un
Ýþletme Frekansý : 50/60 Hz.
Çýkýþ Kontaðý : 1 Enversör 8A/2000 VA (NO: 8A, NC: 6A)Cos =1ϕ
Tekrarlama Hatasý : +/-%0.1
Reset Süresi : <=150 msn.
Ortam Sýcaklýðý : -5°C ; +50°C
Boyutlar : Tip PK22
Koruma Sýnýfý : IP 20
Baðlantý Þekli : Klemensli, klemens rayýna montaj, (panoya
vida ile montaj adaptör parçasý ile mümkündür.
Bakýnýz Þekil 5)
Koli Aðýrlýðý : 2.5kg. (Bir kolide 24 adet)
Boyutlar
Baðlantý Þekli
Önemli Uyar :ý
1) Ý sürede belirtilen deðerlere yükseltilmelidir.þletme gerilimi 1 sn.den kýsa bir
2) Jeneratörle kullanmayýnýz.
(Þekil 5)
ÇOK FONKSiYONLU ZAMAN RÖLELERÝ
( )MCB-7 MCB-8 MCB-9
(TÝP PK 22)
35
23
12
19
Sürelerin Ayarlanma
ON ve OFFresinin Ayarlanmasý
Zaman bölgesi sim trimpotunu ve toff p1-ya da t
on trimpotunu
kullanarak þu forl uyanca hesaplanýr: a, seçilen zaman bölgesinin
sýrý; t, istenen zaman; x, trimpotun konumu olmak üzere;
1-ER Fonksiyonu
T o
2-EM Fonksiyonu
3-Kapal Flaþörý
4-Açýk Flaþör
MCB9
MCB8
U
T on
U
Þekil-4
Mod seçimi (Fonksiyon Tablosu)
a
10.t
X=
ve
Örnek olarak;
t
rimpotun konumu
=30s 3
10
t= .30s = 9 s
t
rimpotun konumu
=10h 10.5
10h
x= = 5
5 saate ayarlamak isteniyorsa;
Ýstenen zaman
A2
A1
13
2
A3
MCB 7-8-9
ton yada toff trimpotu 3ü gösteriyorsa
ON
OUT
t
1s
10 s
30h 10h
60m
10m
60s
30s
10
8
64
0
2
MCB-7
tON
ON
OUT
tOFF
1s
10 s
30h 10h
60m
10m
60s
30s
10
8
64
0
2
10
8
64
0
2
MCB-8
MCB-7, MCB-8, MCB-9
Mikroiþlemci taban elektronik zaman röleleridir. 0, sn.den 30 saate1
kadar hassas olarak ayarlanabilen zaman skalasý, dört farklý çalýþma
modu ince ve dar boyutuyla çok amaçlý kullanýma( ) MCB-9
uygun olarak tasarlanþlardýr.
MCB-7
ER MODU
MCB-7, ER fonksiyonunda çaþan bir
zaman rölesidir.0. saniyeden 30 saate1
kadar ayarlanabilir.
MCB-8, kullanýnýn istine re ER ya
da EM fonksiyonunda çalýþan bir
zaman lesidir. 0. saniyeden 30 saate1
kadar ayarlanabilir.
MCB-8
ER MODU
EM MODU
tON
ON
OUT
tOFF
1s
10 s
30h 10h
60m
10m
60s
30s
10
8
64
0
2
10
8
64
0
2
MCB-9
MCB-9
ER MODU
EM MODU
FLAÞÖR
AÇIK FLAÞÖR
KAPALI FLAÞÖR
M C B - 9 , k u l l a n ý c ý n ý n i s t e ð i n e g ö r e E R ,
EM, Kapa lý F la þör p 1-y a da Açý k Fl aþ ör ola rak
çalýþabilen bir zaman rölesidir. 0. saniyeden1
30 saate kadar ayarlanabilir.
x
10
t= .a
30h 10h
1s
10s
60m
10m
60s
30s
30h 10h
1s
10s
60m
10m
60s
30s
100
8
64
2
Doðru Kullaným ve Güvenlik Þartlarý:
Aþagýdaki þartlara uyulmamasý halinde ölüm ve ciddi yaralanmalar olabilir.
- Cihaz baðlanýrken bütün enerjiyi kesiniz.
- Cihaz þebekeye baðlandýðýnda ön paneli çýkartmayýnýz.
- Cihazý solvent yada benzeri bir madde ile temizlemeye çalýþmayýnýz.
Sadece kuru bez kullanýnýz.
- Baðlantýlarý kontrol ediniz.
- Elektriksel cihazlar sadece bayiniz tarafýndan tamir edilmelidir.
- Cihaz sadece pano tipi montaj içindir.
- Kullanýlacak sigorta F tipi olmalý ve akým sýnýr deðeri 1A olmalýdýr.
zaman bölgesi
üst deri
zaman bölgesi
üst deri
19
61
90
28
48
58
45
A2952/Rev.5
0.1-1 sn.
ZAMAN
BÖLGESÝ
9 dk.-30 saat
0.1-10 sn.
0.2-30 sn.
0.3-60 sn.
3 sn.-10 dk.
15 sn.-60 dk.
3 dk.-10 saat
MCB-7/8/9
AYARLANABÝLÝR
ZAMAN ARALIÐI
MCB-7/8/9
1 sn.
30 saat
10 sn.
30 sn.
60 sn.
10 dk.
60 dk.
10 saat
ZAMAN TABLOSU
T o
U
T on
T on
U
T o
Yukarýdaki önlemlerin uygulanmamasý sonucu doðabilecek istenmeyen
durumlardan üretici rma hiç bir þekilde sorumlu tutulamaz.
A1-A2 : 115/127/220/230 VAC
A3-A2 : 12 VAC/DC
24 VAC/DC
100
8
64
2
Technical Data
Dimensions
Connection Diagram
Caution:
1) Rated voltage must raise to the indicated value in less than 1s.
2) Do not use generatorwith .
(Figure 5)
MULTI-FUNCTIONAL TIMER
( )MCB-7 MCB-8 MCB-9
(TÝP PK 22)
35
23
12
19
Time Settings
Adjusting ON and OFF Time
It is calculated by selecting time region knob and using t
off or ton knob
as the formula: a, limit of time region;
t, required time; x, position of knob;
1-ER Function
T o
2-EM Function
3-O Flashern
4-O Flasher
MCB9
MCB8
U
T on
U
Figure-4
Mod selection (Function Table)e
a
10.t
X=
ve
For example;
Position of knob
=30s 3
10
t= .30s = 9 s
Position of knob
=10h 10.5
10h
x= = 5
if required to adjust 5 hours;
Required time
A2
A1
13
2
A3
MCB 7-8-9
if ton or toff knob shows 3;
ON
OUT
t
1s
10 s
30h 10h
60m
10m
60s
30s
10
8
64
0
2
MCB-7
tON
ON
OUT
tOFF
1s
10 s
30h 10h
60m
10m
60s
30s
10
8
64
0
2
10
8
64
0
2
MCB-8
MCB-7, MCB-8, MCB-9 multifunctional microprocessor based timer
relay. It designed with the ne adjustable scale from 0.1 sec. to 30 h with
dierent programming mode (MCB-9) and with the slim case.s
MCB-7
ER MODE
MCB-7, is a time relay that works at ER function
It can be adjusted from 0. seconds to 30 hours.1
MCB-8, is a time relay that works at ER or
EM function. It can be adjusted from 0. seconds to1
30 hours.
MCB-8
ER MODE
EM MODE
tON
ON
OUT
tOFF
1s
10 s
30h 10h
60m
10m
60s
30s
10
8
64
0
2
10
8
64
0
2
MCB-9
MCB-9
ER MODE
EM MODE
FLASHER
ON FLASHER
OFF FLASHER
MC B-9, is a time relay that works as ER,EM,
Off Flasher or On Flasher according to users
require.
It can be adjusted from 0. seconds to 30 hours.1
x
10
t= .a
30h 10h
1s
10s
60m
10m
60s
30s
30h 10h
1s
10s
60m
10m
60s
30s
100
8
64
2
time region
maximum value
time region
maximum value
PRECAUTIONS FOR INSTALLATION AND SAFE USE
Failure to follow those instructions will result in death or serious injury.
- Disconnect all power before working on equipment..
- When the device is connected to the network, do not remove the front
panel.
- Do not try to clean the device with solvent or the like.Only clean with dry
cloth.
- Verify correct terminal connections when wiring.
- Electrical equipment should be serviced only by your component seller.
- Mount device to the panel
19
61
90
28
48
58
45
A2951/Rev.3
0.1-1 s.
TIME
INTERVAL
9 min.-30 hour
0.1-10 s.
0.2-30 s.
0.3-60 s.
3 s.-10 min.
15 s.-60 min.
3 min.-10 hour
MCB-7/8/9
ADJUSTABLE
TIME VALUE
MCB-7/8/9
1 s.
30 hour
10 s.
30 s.
60 s.
10 min.
60 min.
10 hour
TIME TABLE
T o
U
T on
T on
U
T o
No responsibility is assured by the manufacturer or any of its subsidiaries
for any consequences arising out of the use of this material.
Rated Voltage (Un) : 220 VAC, 230 VAC, 240 VAC, 24 VAC/DC
(115,127 V AC and 12 VAC/DC available upon request)
Operating Range : (0.9-1.1) x Un
Operating Frequency : 50/60 Hz.
Output Contact : 1 Changeover 8A/2000 VA (NO: 8A, NC: 6A)Cos =1ϕ
Repetition Error : +/-%0.1
Reset Time : <=150 msec.
Ambient Temperature : -5°C ; +50°C
Dimensions : Tip PK22
Protection Class : IP 20
Connection : Slimline,Terminal (Panel mount is available
with the plastic adapter part.
Refer to fig. 5
Package Weight : 2.5 kg. (24 pcs. per package)
A1-A2 : 115/127/220/230 VAC
A3-A2 : 12 VAC/DC
24 VAC/DC
Vertrieb durch TDE Instruments GmbH

Produktspezifikationen

Marke: Entes
Kategorie: niet gecategoriseerd
Modell: MCB-7

Brauchst du Hilfe?

Wenn Sie Hilfe mit Entes MCB-7 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung niet gecategoriseerd Entes

Bedienungsanleitung niet gecategoriseerd

Neueste Bedienungsanleitung für -Kategorien-