EnerGenie EG-UPS-PS3000-01 Bedienungsanleitung
EnerGenie
Unterbrechungsfreies Stromversorgungssystem
EG-UPS-PS3000-01
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für EnerGenie EG-UPS-PS3000-01 (28 Seiten) in der Kategorie Unterbrechungsfreies Stromversorgungssystem. Dieser Bedienungsanleitung war für 29 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/28
Line-interactive UPS
User Manual
~ 1 ~
Table of Contents
1 Safety Information ......................................................................................................................... ï¼’
ï¼’
ï¼’
ï¼’ï¼’
2 Product Overview ............................................................................................................................ 4
2.1 Specifications 4..................................................................................................................................
2.2 Front panel features ....................................................................................................................... 7
2.2.1 Tower panel 7.................................................................................................................................................................
2.2.2 SRT panel 7....................................................................................................................................................................
2.3 Rear panel features 7.......................................................................................................................
2.3.1 Tower rear panel 7.........................................................................................................................................................
2.3.2 SRT rear panel 8............................................................................................................................................................
3 Installation........................................................................................................................................ 9
3.1 Unpacking inspection .................................................................................................................... 9
3.2 Installation information .................................................................................................................. 9
3.2.1 Safety precautions 9......................................................................................................................................................
3.2.2 Tower installation 10......................................................................................................................................................
3.2.3 Long backup model UPS installation 12......................................................................................................................
3.2.4 SRT installation 13.........................................................................................................................................................
4 Operation 15........................................................................................................................................
4.1 Buttons operation 15.........................................................................................................................
4.2 LED Indicator light 16........................................................................................................................
4.3 LCD display interface 16..................................................................................................................
4.4 UPS On/Off operation 18.................................................................................................................
4.4.1 Turn on the UPS 18........................................................................................................................................................
4.4.2 Turn off the UPS 19........................................................................................................................................................
4.5 Parameter query operation ......................................................................................................... 19
5 UPS Settings.................................................................................................................................. 21
6 Troubleshooting............................................................................................................................ 25
6.1 Fault messages 25............................................................................................................................
6.2 Common faults and processing ................................................................................................. 26
7 Maintenance 27...................................................................................................................................
7.1 Preventive maintenance ............................................................................................................. 27
7.2 Battery maintenance 27....................................................................................................................
Line-interactive UPS
User Manual
~ï¼’~
1 Safety Information
ï‚ŸPlease charge the product for more than 8 hours before using.
ï‚ŸWhen the battery has been discharged or the storage period has been more than 3 months,
the battery shall be charged for more than 8 hours in time, so as to ensure it is
fully-charged and prevent it from being damaged.
ï‚ŸThis product is specially designed for group computers. It shall not be connected with
inductive loads (e.g. motor, refrigerator, etc.). It is not recommended for life supporting
system and other specific major equipments;
ï‚ŸKeep a distance of at least 50 cm from the display during installation of the product.
It’s normal for the surface temperature of the cabinet may rise to 50 during use of the℃
product.
ï‚ŸDo not overload the product.
ï‚ŸDo not open the cabinet of the UPS due to hazard of electrical shock, Contact your local
service center if maintenance or repair is needed.
ï‚ŸUPS inner short circuit will cause electric shock or fire danger. Do not put any liquid vessel
on the UPS.
ï‚ŸCut off the power supply rapidly if the UPS work abnormal, and contact your local dealer.
ï‚ŸMake sure not to keep or use the product in following environment.
No good air circulation
Place having flammable gas or corrosive material or lots of dust
Place under abnormal high or low temperature (above 40 or below 0 ), or high℃ ℃
humidity (above 90%)
Place where there is direct sunlight or near the heating appliance
Place where there is violent vibration
Outdoor
ï‚ŸDo not use liquid extinguisher if there is a fire, a dry powder extinguisher is recommended.
ï‚ŸPlace the UPS near the mains source so that can cut off utility power without any delay in
case of emergency.
ï‚ŸWhen the UPS is to be moved or reconnected, ensure that the AC input power supply is
cut off and the UPS is completely turned off, otherwise the output end may be electrified
and result in electric shock.
ï‚ŸThe battery life is shortened as the ambient temperature rises. Periodic battery
replacement can ensure UPS working properly and enough backup time.
ï‚ŸThe battery maintenance shall only be carried out by the personnel having professional
knowledge of batteries.
Line-interactive UPS
User Manual
~3~
ï‚ŸBatteries may cause electric shocks and have a high short circuit current, follow below
requirements before installing or replacing the batteries:
Remove wristwatches, rings, jewelry and other conductive materials
Only use tools with insulated grips and handles
Wear rubber shoes and gloves
Do not put the metal tools or paSRT on the batteries
Before disconnecting the terminals from the batteries, cut off all the loads to the
batteries first
ï‚ŸDo not short circuit the positive and negative terminals of batteries, otherwise it may result
in electric shocks or fire.
ï‚ŸIf need to extend the backup time of the standard model UPS (external battery), loading
capacity should be reduced to 50%.
Warning
ï‚ŸThe equipment must be grounded. When utility power is connected, the system must be
grounded reliably.
ï‚ŸImproper operation will result in huge losses. Please be sure to operate the product
according to the requirements of the user manual.
ï‚ŸUPS should be used at an altitude below 1,000 m. If use it at an altitude of more than 1,000
m , derating output is required, as shown in below table:
ï‚ŸLoad capacity at a high altitude location = rated power *derating coefficient
(Corresponding to the altitude).
Altitude (m)
1000
1500
2000
2500
3000
3500
4000
4500
5000
Derating
coefficient
100%
95%
91%
86%
82%
78%
74%
70%
67%
Produktspezifikationen
Marke: | EnerGenie |
Kategorie: | Unterbrechungsfreies Stromversorgungssystem |
Modell: | EG-UPS-PS3000-01 |
Display-Typ: | LED |
Akustische Signale: | Ja |
USB Anschluss: | Ja |
Breite: | 467 mm |
Tiefe: | 190 mm |
Gewicht: | 28100 g |
Produktfarbe: | Schwarz |
Akkuladezeit: | 12 h |
Akku-/Batterietechnologie: | Plombierte Bleisäure (VRLA) |
Höhe: | 336 mm |
Energieschutzeigenschaften: | Overload, Short circuit |
Stecker: | C14-Koppler |
Betriebstemperatur: | 0 - 40 °C |
Relative Luftfeuchtigkeit in Betrieb: | 10 - 90 % |
Betriebsanleitung: | Ja |
Reaktionszeit: | 10 ms |
Geräuschpegel: | 50 dB |
Akku-/Batteriespannung: | 12 V |
Batteriekapazität: | 9 Ah |
Formfaktor: | Tower |
Ausgangsleistung: | 220 W |
Eingangsfrequenz: | 50/60 Hz |
Ladestrom: | 1.7 A |
Anzahl der AC-Ausgänge: | 6 AC-Ausgänge |
Eingangs-Betriebsspannung (min): | 220 V |
Eingangs-Betriebsspannung (max): | - V |
Ausgangskapazität: | 3 kVA |
Ausgangs-Betriebsspannung (min): | 220 V |
Ausgangs-Betriebsspannung (max): | - V |
Automatische Spannungsregulierung: | Ja |
AC-Steckertypen: | C13-Koppler |
Typische Backup-Zeit bei halber Belastung: | 30 min |
Typische Backup-Zeit bei voller Belastung: | 10 min |
Wellenform: | Sine |
Output Frequenz: | 50/60 Hz |
Batteriebreite: | 151 mm |
Batterietiefe: | 65 mm |
Batteriehöhe: | 94 mm |
Brauchst du Hilfe?
Wenn Sie Hilfe mit EnerGenie EG-UPS-PS3000-01 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem EnerGenie
30 Mai 2024
30 Mai 2024
30 Mai 2024
2 Mai 2024
29 April 2024
21 April 2024
25 März 2024
19 März 2024
12 März 2024
3 Februar 2024
Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem
- Unterbrechungsfreies Stromversorgungssystem Approx
- Unterbrechungsfreies Stromversorgungssystem HP
- Unterbrechungsfreies Stromversorgungssystem Voltcraft
- Unterbrechungsfreies Stromversorgungssystem Siemens
- Unterbrechungsfreies Stromversorgungssystem Schneider
- Unterbrechungsfreies Stromversorgungssystem Lenovo
- Unterbrechungsfreies Stromversorgungssystem Tripp Lite
- Unterbrechungsfreies Stromversorgungssystem Adj
- Unterbrechungsfreies Stromversorgungssystem JUNG
- Unterbrechungsfreies Stromversorgungssystem Block
- Unterbrechungsfreies Stromversorgungssystem Digitus
- Unterbrechungsfreies Stromversorgungssystem APC
- Unterbrechungsfreies Stromversorgungssystem CyberPower
- Unterbrechungsfreies Stromversorgungssystem Eaton
- Unterbrechungsfreies Stromversorgungssystem Furman
- Unterbrechungsfreies Stromversorgungssystem Riello
- Unterbrechungsfreies Stromversorgungssystem Steren
- Unterbrechungsfreies Stromversorgungssystem Puls Dimension
- Unterbrechungsfreies Stromversorgungssystem Atlantis Land
- Unterbrechungsfreies Stromversorgungssystem Phoenix Contact
- Unterbrechungsfreies Stromversorgungssystem Middle Atlantic
- Unterbrechungsfreies Stromversorgungssystem Minuteman
- Unterbrechungsfreies Stromversorgungssystem Salicru
- Unterbrechungsfreies Stromversorgungssystem Maruson
- Unterbrechungsfreies Stromversorgungssystem Minute Man
- Unterbrechungsfreies Stromversorgungssystem DEXP
- Unterbrechungsfreies Stromversorgungssystem Bxterra
- Unterbrechungsfreies Stromversorgungssystem Altronix
- Unterbrechungsfreies Stromversorgungssystem FSP
- Unterbrechungsfreies Stromversorgungssystem PowerWalker
- Unterbrechungsfreies Stromversorgungssystem FSP/Fortron
Neueste Bedienungsanleitung für -Kategorien-
22 Juni 2024
22 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024