EMOS M0003B Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für EMOS M0003B (32 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/32
2201015000_31-M0003B_00_01 74 × 105 mm
M0003B | VT-211
GB Voltage Tester
CZ Zkoušečka napětí
SK Skúšačka natia
PL Tester napięcia
HU Fesltségvizs
SI Elektronski preizkušavalec
RS|HR|BA|ME Ispitivač napona
DE Spannungspfer
UA Тестер напруги
RO|MD Tester tensiune
LT Įtampos testeris
LV Sprieguma testeris
EE Pingetester
BG Тестер за напрежение
www.emos.eu
2
1
1
2
3
4
5
6
7
8
3
GB | Voltage Tester
VT-211 is a tester designed for two-pole measurement of DC and AC voltage in a range of 6 to 400
V and frequency of 0–60 Hz, and for determining the polarity of DC voltage. The tester complies
with standard EN 61243-3:2014 in the 6–400 V / CAT III 400 V range. The tester can be used for
making measurements on electrical wiring and devices falling within overvoltage category CAT
III 400 V. Overvoltage category CAT III also includes category CAT II for electrical devices and
equipment with special requirements for safety and usability. These are, for instance, domestic
wiring, protective installations, power sockets, switches, circuit breakers, etc.
Technical Specications
Category and measurement range: 6 V – 12 V – 24 V – 50 V – 120 V – 230 V – 400 V AC/DC, CATIII
Indication: gradual illumination of LEDs
Frequency range: 0–60 Hz
Working cycle: max. 10 s on (measuring), 240 s downtime (no measuring)
Enclosure rating: IP54
Operating temperature: -10 °C to +50 °C
Operating humidity: 20 to 96 %
Power supply: from the voltage source
Description of Tester
1 – Tester barrier
2 – Measuring tip of the tester
3 – Removable cover of the tester tip
4 – Polarity LEDs
5 – LEDs indicating AC voltage
6 – Mobile measuring tip
7 – Removable cover of the mobile
tester tip
8 – Barrier of the mobile section of
the tester
Use
The tester indicates voltage by lighting up LEDs up to the measured voltage. First, touch the
live portion (L) of the circuit with the tip located on the xed part of the tester. Then touch the
neutral portion (N) using the mobile tip. If the circuit is powered and you are measuring correctly,
LEDs indicating the corresponding voltage will light up. When measuring DC voltage, only the
corresponding polarity (+/-) will be indicated. The xed tip is the positive pole.
Maintenance
The tester is maintenance-free.
Cleaning
The body of the tester may occasionally be cleaned with a soft cloth slightly moistened in a mild
solution of a common household cleaner. Do not use aggressive solvents. Make sure water does
not enter the interior of the tester. Could cause damage or short circuit.
WARNING
Do not use the device if the lead or cover are damaged.


Produktspezifikationen

Marke: EMOS
Kategorie: Nicht kategorisiert
Modell: M0003B

Brauchst du Hilfe?

Wenn Sie Hilfe mit EMOS M0003B benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert EMOS

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-