I N S T A L L A T I O N 8380
GateMag®
Electromagnetic Lock
© 2014 RutheRfoRd ContRols Int’l | A doRMA GRoup CoMpAny
www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com
IS8380 PCN14053
R10/14TG
Pre-Installation Instructions
1. This product must be installed according to all applicable
building and life safety codes.
2. Due to the variety of mounting configurations available with
this product, a survey and assessment of the physical area
in which the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally
sound prior to installation of the electromagnetic lock. The
structural integrity of the mounting surfaces must be strong
enough to meet or exceed the holding force of the product.
4. The product must be protected from potential damage due
to intruders or tampering.
5. The product should be installed in a location that will not
hinder or create a potential safety hazard to authorized
personnel accessing the protected area.
6. Because electromagnetic locks are used in a variety of
applications and different door frame configurations, an
experienced installer with knowledge of this product must
make a determination of the optimal mounting method for
this specific application.
7. The components, hardware, installation instructions and
mounting template included with this product are intended
for use on swinging and sliding gates.
8. Do not use as a doorstop. This will void warranty.
9. Separate accessories not included with this product may be
used in the following applications:
 • Inswingingdoorsandgates
 • Slidinggatesanddoors
Refer to the Template for further information. Accessories
may impact holding force.
10. Installation of this product should be done by an
experienced installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound
be applied to all screws during installation to reduce chance of
screws loosening over extended time.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
1. Please read template mounting instructions and use template
provided for installing the electromagnetic lock.
NOTE: During installation of the armature plate to the door it is
essential that the armature plate remains movable. The armature
plate must be allowed to pivot on the center-mounting bolt to
allow proper alignment with the magnet surface. If the plate is not
aligned with the magnet surface, the lock may lose holding force
or not lock at all.
The head of the armature mounting bolt ships with a rubber
washer affixed to it. This washer should project slightly beyond
the surface of the armature plate. This is to allow the washer to
expand when power is removed and break the air vacuum between
the plate and the magnet surface. If this washer is removed or
trimmed the lock will appear to have some holding force even
when power is removed.
For added safety, thread locking compound has been provided for
the armature plate bolt and the four electromagnetic lock mounting
screws.
WARNING: Improper installation, maintenance, inspection or
usage of the product or any related accessories or parts may
cause the electromagnetic lock, armature plate and associated
hardware to disengage and fall, causing serious bodily injury
and property damage. Rutherford Controls Int’l Inc. and/or
Rutherford Controls Int’l Corp. will not be liable to the installer,
purchaser, end user or anyone else for damage or injury to
person or property due to improper installation, care, storage,
handling, maintenance, inspection, abuse, misuse or act of
God or nature involving this product or any related accessories
or parts.
2. Connecting wire should be of sufficient gauge to prevent line loss.
3. The 8380 electromagnetic lock requires a filtered, regulated DC
power source for optimal performance.
Instructions
24 VDC INPUT
Twist purple and blue wires together; then connect brown wire to positive
side of power source and yellow wire to negative side of power source.
Wiring Instructions
12 VDC INPUT
Twist brown and purple wires together and connect to positive side
of power source. Twist blue and yellow wires together and connect
to negative side of power source.
Magnet Locked When the magnet is locked, the common contact
(black) and the normally open contact (green or white) are closed. The
normally closed contact (red) would be open.
Magnet Unlocked When the magnet is unlocked, the common
contact (black) and the normally closed contact (red) are closed.
Reed switch is operational when the magnetic lock is powered and the
door is in the closed position.
Reed switch contacts are rated 24VDC @ 0.2amps maximum.
WARNING Misconnection of the wires will cause the MOV inside the electromagnetic lock to fail.
This will NOT be covered under warranty.
BROWN
PURPLE
BLUE
YELLOW
RED
GREEN
BLACK
NC
NO
Common
BROWN
PURPLE
BLUE
YELLOW
RED
GREEN
BLACK
+
--
BROWN
PURPLE
BLUE
YELLOW
RED
GREEN
BLACK
+
--
8380 Electromagnetic Lock Installation Instructions (Continued)
To Ensure Instant Release All switching devices must be wired in between
the DC power source and the positive terminal of the lock in Fig 2.
Switching the negative power supply line will not allow the lock to
release immediately. RCI electromagnetic locks contain MOV’s for
surge suppression and do not require any additional suppression to
be added during installation. The installation of diodes across the lock
input terminals will cause a delay in release.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE
END-USER UPON COMPLETION OF THE INSTALLATION.
Fig. 2 Power Connections
SWITCH
+
-
INCORRECT
CORRECT
+
-
SWITCH
FILTERED DC SUPPLY
FILTERED DC SUPPLY
Remote Lock Status
Inspection and Maintenance
This product and all related accessories or parts must be inspected and maintained on a . Contacting surfaces of the electromagnetic quarterly basis
lock and armature plate must be kept free of contaminating materials. Surfaces must be cleaned periodically with a non-abrasive cleaner.
All mounting fasteners must be inspected on a . When properly installed, the ends of the armature plate allow a slight movement but quarterly basis
the plate will feel secure when grasped at the bolt. There should be no movement to the mounting bracket or housing of the electromagnetic lock.
For added safety, thread locking compound has been provided for the armature plate bolt and the four captive electromagnetic lock mounting
screws.
WARNING: Improper installation, maintenance, inspection or usage of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware to disengage and fall, causing serious bodily injury and property damage.
8380 Electromagnetic Lock Installation Instructions (Continued)
Troubleshooting
NOTE: Specifications are subject to change without notice.
NOTE: All RCI electromagnetic locks must be powered with
filtered and regulated DC power supplies such as the RCI 10
Series UL Listed power supply. RCI offers a full line of power
supplies and switching devices that are suitable for use with
the 8300 Series locks.
Power Input Requirements
Problem SolutionPossible Cause
Door will not lock
(no magnetic attraction)
Absence of DC voltage at magnet
terminals.
Check power supply and wiring.
Reduced holding force Inadequate contact between
armature and face of magnet.
Ensure mating surfaces are clean and in proper alignment.
Make sure to follow the armature plate mounting instructions on the
template and Page 1 of this install.
Delay in lock release Circuit not broken (open) between
power supply and magnetic lock.
Secondary diode installed
Ensure that switching devices are interrupting the DC power and not
the AC power supply voltage. Ensure rubber washer on armature plate
mounting bolt has not been removed or damaged.
Check that switching device interrupts the positive wire and not the
negative wire. (See Fig. 2)
Removed any diodes or other supression devices that may be installed.
RLS status incorrect Misalignment of armature plate. Check to see that alignment agrees with template. Reposition armature
plate. Contact manufacturer.
Voltage Current
12VDC 0.48A
24VDC 0.24A
13/ 4
(45mm)
5/ ”8
21/ 2
(63mm)
23/ 8
(61mm)
(16mm)
7 7/ 16
(190mm)
87/ 8
(225mm)


Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: RCI 8380

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba RCI 8380 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-