I N S T A L L A T I O N 8371/8372
Surface MiniMag® Electromagnetic Locks
1. Mount the electromagnetic lock to the door frame as outlined
on the installation template included with the product.
NOTE: During installation of the armature plate to the door it is
essential that the armature plate remains movable. The armature
plate must be allowed to pivot on the center-mounting bolt to allow
proper alignment with the magnet surface. If the plate is not aligned
with the magnet surface, the lock may lose holding force or not
lock at all.
The head of the armature mounting bolt ships with a rubber washer
affixed to it. This washer should project slightly beyond the surface
of the armature plate. This is to allow the washer to expand when
power is removed and break the air vacuum between the plate
and the magnet surface. If this washer is removed or trimmed the
lock will appear to have some holding force even when power is
removed.
For added safety, thread locking compound has been provided for
the armature plate bolt and the four captive electromagnetic lock
mounting screws.
WARNING: Improper installation, maintenance, inspection or
usage of the product or any related accessories or parts may
cause the electromagnetic lock, armature plate and associated
hardware to disengage and fall, causing serious bodily injury
and property damage. Rutherford Controls Int’l Inc. and/or
Rutherford Controls Int’l Corp. will not be liable to the installer,
purchaser, end user or anyone else for damage or injury to person
or property due to improper installation, care, storage, handling,
maintenance, inspection, abuse, misuse or act of God or nature
involving this product or any related accessories or parts.
2. Route the power supply wire through door frame and into
magnet housing. Connecting wire should be of sufficient gauge
for the lock being installed and the distance being run. (See table
on page 6.)
© 2015 RUTHERFORD CONTROLS INT’L | A DORMA GROUP COMPANY
WWW.RUTHERFORDCONTROLS.COM • PHONE: 1.800.265.6630 • FAX: 1.800.482.9795 • E-MAIL: SALES@RUTHERFORDCONTROLS.COM
IS8371/72 PCN15010
R10/15GR-2
In or Out... we make it Easy!®
Instructions
Pre-Installation Instructions
1. This product must be installed according to all applicable
building and life safety codes.
2. Due to the variety of mounting configurations available with
this product, a survey and assessment of the physical area
in which the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally
sound prior to installation of the electromagnetic lock. The
structural integrity of the mounting surfaces must be strong
enough to meet or exceed the holding force of the product.
4. The product must be protected from potential damage due
to intruders or tampering.
5. The product should be installed in a location that will not
hinder or create a potential safety hazard to authorized
personnel accessing the protected area.
6. Because electromagnetic locks are used in a variety of
applications and different door frame configurations, an
experienced installer with knowledge of this product must
make a determination of the optimal mounting method for
this specific application.
7. The components, hardware, installation instructions and
mounting template included with this product are intended
for use on outswinging doors.
8. Do not install this product on the exterior of buildings.
9. Do not use as a doorstop. This will void warranty.
10. Separate accessories not included with this product must
be used in the following applications:
• Inswinging doors
• Narrow head jamb situations or center-hung doors
• Wherever there is insufficient space on the door
frame header to mount the lock
• Glass or Herculite doors that do not have a door frame
• Hollow metal or wood frames where the door stop is
not thick enough to allow the product to be installed
• Wherever an obstruction in the door prevents
installation of the armature plate at a proper height
• Doors that do not permit the armature plate to be
mounted low enough to meet the magnet surface
Refer to the Product Accessories Guide section of
the Installation Instructions for further information.
Accessories may impact holding force.
11. Installation of this product should be done by an
experienced installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound
be applied to all screws during installation to reduce chance of
screws loosening over extended time.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
8371/ 8372 Electromagnetic Lock Installation Instructions (Continued)
2
SCS (Security Condition Sensor) with LED
This feature can detect the quality of the locking bond between the
surface of the magnet and the armature plate. The sensitivity of this
feature is such that a foreign object with a thickness of .007” (.18mm)
is sufficient to allow the sensor to detect a problem.
Due to the sensitivity of this feature and the necessity to maintain a
reliable locking bond, these surfaces must be kept free of contaminating
materials. Both the lock surface and the armature plate must be cleaned
periodically with a non-abrasive cleanser. Alignment of armature plate
and magnet is required to ensure proper function of sensor.
DSS (Door Status Sensor)
The DSS option monitors the position of the door upon which the lock
is installed. A SPST reed switch eliminates the need for extra sensors
to be installed on the door for notification of security or access control
systems. The DSS option comes with a magnet pre-installed into the
lock armature plate for signaling the reed switch in the housing when
the door is closed. Care should be taken during the final testing of the
lock to ensure that the DSS option is operating in the desired manner.
Magnet power from
Power Supply
+12/24VDC input
- (Ground)
Jumper
12VDC
Jumper
24VDC
(
preset )
Power Input Requirements
MODE 12VDC 24VDCL
8371 0.52A 0.26A
8372 1.04A 0.52A
2 x BLUE LEADS Normally Open
FOR MODELS WITH OPTIONAL DSS
contacts are rated 0.20A@12VDC
and 0.12A @ 24VDC
shown with Door Open
Wiring : For Unmonitored or DSS Sensor Models
12 1224
G B R
LED
RB G
HR
- VDC C NC NO
G B R
LED
Voltage Jumpers
}
Optional SCS Sensor
SPDT Output contacts rated
for maximum 1.00 Amperes
at 24VDC
Common
Normally Closed
Normally Open
2 x BLUE LEADS Normally Open
Optional DSS contacts rated at
0.20A@12VDC and 0.12A @ 24VDC
Both the SCS and DSS options are shown
with Door Open
Tip: Fully depress orange tab to insert wires
-
LED
R B G
G B R
LED
12 1224
R
BG
HR
VDCCNC NO
Voltage Jumpers
}
Optional SCS Sensor
SPDT Output contacts rated
for maximum 1.00 Amperes
at 24VDC
Common
Normally Closed
Normally Open
Optional DSS contacts rated at
0.20A@12VDC and 0.12A @ 24VDC
Both the SCS and DSS options are shown
with Door Open
Tip: Fully depress orange tab to insert wires
2 x BLUE LEADS Normally Open
8371 SCS and 8372 SCS
Side 1
8372 SCS
Side 2
Wiring : For SCS or SCS/DSS Combination Models
Green LED indicates door locked with secure bond.
Red LED indicates door unlocked or poor bond.
UL 294 Performance Ratings:
Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I
Power Connections
SWITCH
+
-
FILTERED DC SUPPLY
+
-
SWITCH
FILTERED DC SUPPLY
INCORRECT
CORRECT
8371/ 8372 Electromagnetic Lock Installation Instructions (Continued)
3
Fig. 1
Fig. 2 – Lock Mounting
Anti-tamper
screw Wiring cavity
screw
Captive
mounting
bolts
Fig. 3
Anti-tamper screw
(under wiring cavity)
NOTE: All RCI electromagnetic locks must be powered with filtered
and regulated DC power supplies such as the RCI 10 Series UL Listed
power supply. RCI offers a full line of power supplies and switching
devices that are suitable for use with the 8371 and 8372 Surface
MiniMag® locks.
To Ensure Instant Release All switching devices must be wired in between
the DC power source and the positive terminal of the lock as shown.
Switching the negative power supply line will not allow the lock to
release immediately. RCI electromagnetic locks contain MOV’s for
surge suppression and do not require any additional suppression to
be added during installation. The installation of diodes across the lock
input terminals will cause a delay in release.
Anti-Tamper Feature - Two screws prevent insertion of an Allen
wrench into the captive mounting bolt opening on the bottom of the
lock. Fig. 2 shows their location. One screw also secures the wiring
cavity cover. The mounting plate cannot be separated from the lock
without removing these two screws. There is an additional anti-
tamper screw under the wiring cavity cover. See Fig. 3.
Specifications
Mechanical: including 3/16” [5mm] mounting bracket:
8371 Lock Dimensions:
1”D x 1-7/8”W x 9-3/8”L (25 x 48 x 238mm)
8372 Lock Dimensions:
1”D x 1-7/8”W x 18-3/4”L (25x 48 x 476mm)
Armature Plate Dimensions:
1/2”D x 1-1/2”W x 7-1/4”L (13 x 38 x 185mm)
Electrical:
Voltage: 12VDC or 24VDC
Current: Max 0.52A at 12VDC (each lock on 8372 model)
Max 0.26A at 24VDC (each lock on 8372 model)
SCS Output Relay*: SPDT relay. Contacts rated at 1.0A@24VDC
DSS Reed Switch*: Magnetically actuated SPST switch.
Contacts rated for 0.20A @12VDC and 0.12A @ 24VDC
* Effective for either resistive or inductive loads
(power factor 0.6 with inductive loads)≥
Environmental:
Not for use in outdoor environments.
Circuit board operating temperature: 32 to 120 F (0 to 49Ëš Ëš Ëš ËšC)
NOTE: Specifications subject to change without notice.
Inspection and Maintenance
This product and all related accessories or parts must be inspected
and maintained on a . Contacting surfaces of the quarterly basis
electromagnetic lock and armature plate must be kept free of
contaminating materials. Surfaces must be cleaned periodically
with a non-abrasive cleaner.
All mounting fasteners must be inspected on a quarterly basis.
When properly installed, the ends of the armature plate allow a
slight movement but the plate will feel secure when grasped at
the bolt. There should be no movement to the mounting bracket
or housing of the electromagnetic lock.
For added safety, thread locking compound has been provided for
the armature plate bolt and the four captive electromagnetic lock
mounting screws.
WARNING: Improper installation, maintenance, inspection or usage
of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware
to disengage and fall, causing serious bodily injury and property
damage.


Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: RCI 8371

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba RCI 8371 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-