INSTALLATION
RCI 8310IQ / 8320IQ
INTELLIMAG ELECTROMAGNETIC LOCKS®
© 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Pre-Installation Instructions
1. This product must be installed according to all applicable
building and life safety codes.
2. Due to the variety of mounting configurations available with
this product, a survey and assessment of the physical area in
which the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally
sound prior to installation of the electromagnetic lock. The
structural integrity of the mounting surfaces must be strong
enough to meet or exceed the holding force of the product.
4. The product must be protected from potential damage due to
intruders or tampering.
5. The product should be installed in a location that will not
hinder or create a potential safety hazard to authorized
personnel accessing the protected area.
6. Because electromagnetic locks are used in a variety of
applications and different door frame configurations, an
experienced installer with knowledge of this product must
make a determination of the optimal mounting method for this
specific application.
7. The components, hardware, installation instructions and
mounting template included with this product are intended for
use on outswinging doors.
8. Do not install this product on the exterior of buildings.
9. Do not use as a doorstop. This will void warranty.
10. Separate accessories must be used in the following
applications:
Inswinging doors
Narrow head jamb situations or center-hung doors
Wherever there is insufficient space on the door
frame header to mount the lock
Glass or Herculite doors that don’t have a door frame
Hollow metal or wood frames where the door
stop is not thick enough to allow the product to
be installed
Wherever an obstruction in the door prevents
installation of the armature plate at a proper height
Doors that do not permit the armature plate to
be mounted low enough to meet the magnet
surface
Refer to the page 5 & 6 Product Accessories Guide for
further information. Accessories may impact holding force.
11. Installation of this product should be done by an
experienced installer with knowledge of this product.
NOTE: It is highly recommended that thread locking
compound be applied to all screws during installation to
reduce chance of screws loosening over extended time.
IS8310-IQ PCN18040
R08-19GR-1
1. Mount the electromagnetic lock to the door frame as outlined
on the installation template included with the product.
NOTE: During installation of the armature plate to the door it is
essential that the armature plate remains movable. The armature
plate must be allowed to pivot on the center-mounting bolt to
allow proper alignment with the magnet surface. If the plate is not
aligned with the magnet surface, the lock may lose holding force
or not lock at all.
The head of the armature mounting bolt ships with a rubber
washer affixed to it. This washer should project slightly beyond
the surface of the armature plate. This is to allow the washer
to expand when power is removed and break the air vacuum
between the plate and the magnet surface. If this washer is
removed or trimmed the lock will appear to have some holding
force even when power is removed.
For added safety, thread locking compound has been provided
for the armature plate bolt and the four captive electromagnetic
lock mounting screws.
WARNING: Improper installation, maintenance, inspection
or usage of the product or any related accessories or parts
may cause the electromagnetic lock, armature plate and
associated hardware to disengage and fall, causing serious
bodily injury and property damage. dormakaba Canada Inc.
and/or dormakaba USA Inc. will not be liable to the installer,
purchaser, end user or anyone else for damage or injury
to person or property due to improper installation, care,
storage, handling, maintenance, inspection, abuse, misuse
or act of God or nature involving this product or any related
accessories or parts.
2. Route the power supply connecting wire through the door
frame and into the wire access hole in the top of the magnet
housing. Connecting wire should be of sufficient gauge for
the lock being installed and the distance being run.
Installation Instructions
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
3. Set the DC voltage jumpers on JP1 as follows.
For 12V operation two jumpers are used; One on the
two upper pins and the other on the two lower ones.
For 24V operation only one jumper is used to connect
the two center pins (factory setting)
Connect the positive (+) lead from the power supply to
TB1-1. Connect the negative (-) lead from the power
supply to TB1-2. For wiring installations, refer to figure
1.
4. Delayed Relock Feature - The delayed relock feature can
be used to momentarily release the lock and keep it
unlocked for a time period from 0 to 90 seconds. The
time delay for this feature can be adjusted by carefully
turning the potentiometer in a counterclockwise
direction to increase delay time. Factory setting is zero
seconds (fully clockwise).
NOTE: On the 8320IQ double-door model turn both
potentiometers counterclockwise to increase the relock
delay.
2
JP1
JP2
TB1
Alarm Time Setting
Voltage Selection
Light Emitting
Diode (LED)
Time Delay Setting (0-90 secs)
CCW increases time delay
N.C
N.O.
Common
N.C
N.O.
Common
-Common (Ground)
+12/24VDC input
Bond Alert Sensor*
Output contacts SPDT rated at
2.0A @ 30VDC max
Magnet power from
Power Supply
Alarm Status*
Output contacts SPDT rated
2.0A @ 30VDC max.
Power Input Requirements
MODEL 12VDC 24VDC
8310IQ 0.59A 0.29A
8320IQ 1.18A 0.58A
*Shown with Door Open/unlocked
Fig. 1 Wiring Schematic
Electromagnetic locks must conform to local fire codes, National Building Codes and Life Safety Codes. See your
Local Authority Having Jurisdiction for specific code requirements.
Alarm
Alarm Status Remote Indication - When the door is closed and
an illegal armature plate is detected, the common contact
(TB1-6) and the normally open contact (TB1-7) are activated
for the preset period of time. The alarm status relay contacts
are rated at 30VDC @ 2.0 amps maximum.
Alarm Time Setting - Refer to figure 1 (JP2). Note 15 or 30
seconds requires one jumper; 60 seconds requires no jumper
and indefinitely requires two jumpers. Unused jumpers can be
stored on a single pin.
15 Seconds 30 Seconds 60 Seconds indefinitely
LSS Remote Indication (Lock Status Sensor)
Magnet Locked - When the magnet is locked, the common
contact (TB1-3) and the normally open contact (TB1-4) are
closed. The normally closed contact (TB1-5) would be open.
Magnet Unlocked - When the magnet is unlocked, the common
contact (TB1-3) and the normally closed contact (TB1-5) are
closed. The LSS relay contacts are rated 30VDC @ 2.0 amps
maximum.
This feature can detect the quality of the locking bond between
the surface of the magnet and the armature plate. The
sensitivity of this feature is such that a foreign object with a
thickness of .007” (.18mm) is sufficient to allow the sensor to
detect a problem.
Due to the sensitivity of this feature and the necessity to
maintain a reliable locking bond, these surfaces must be kept
free of contaminating materials. Both the lock surface and
the armature plate must be cleaned periodically with a non-
abrasive cleanser. Alignment of armature plate and magnet is
required to ensure proper function of sensor.
LED Local Indication (Light Emitting Diode)
Red LED on solid Maglock is unlocked
Green LED on solid Maglock is locked.
Red LED blinking quickly – Illegal armature plate used; alarm
will be activated.
Each individually encoded armature plate is registered to
match it’s own electromagnetic lock.
3
Anti-Tamper Feature - Two screws prevent insertion of an
Allen wrench into the captive mounting screw opening on
the bottom of the lock. Fig. 3 shows their location. One
screw also secures the wiring cavity cover. The mounting
plate cannot be separated from the lock without removing
these two screws.
Inspection and Maintenance
This product and all related accessories or parts must be
inspected and maintained on a . Contacting quarterly basis
surfaces of the electromagnetic lock and armature plate
must be kept free of contaminating materials. Surfaces
must be cleaned periodically with a non-abrasive cleaner.
All mounting fasteners must be inspected on a quarterly
basis. When properly installed, the ends of the armature
plate allow a slight movement but the plate will feel secure
when grasped at the bolt. There should be no movement
to the mounting bracket or housing of the electromagnetic
lock.
For added safety, thread locking compound has been
provided for the armature plate bolt and the four captive
electromagnetic lock mounting screws.
WARNING: Improper installation, maintenance, inspection
or usage of the product or any related accessories or
parts may cause the electromagnetic lock, armature plate
and associated hardware to disengage and fall, causing
serious bodily injury and property damage.
Fig. 3 – Lock Mounting
Anti-tamper
feature screw Anti-tamper
feature and
wiring cavity
screw
Captive
mounting
screw
PLEASE DELIVER ALL INSTALLATION
INSTRUCTIONS TO THE END-USER UPON
COMPLETION OF THE INSTALLATION.
To Ensure Instant Release All switching devices must be
wired in between the DC power source and the positive
terminal of the lock in Fig 2.
Switching the negative power supply line will not allow the
lock to release immediately. RCI electromagnetic locks
contain MOV’s for surge suppression and do not require
any additional suppression to be added during installation.
The installation of diodes across the lock input terminals
will cause a delay in release.
Fig. 2 Power Connections
SWITCH
+
-
INCORRECT
CORRECT
+
-
SWITCH
FILTERED DC SUPPLY
FILTERED DC SUPPLY


Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: RCI 8310IQ

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba RCI 8310IQ benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-