Dormakaba RCI 171HD Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Dormakaba RCI 171HD (2 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 2 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
INSTALLATION
RCI 171HD
MAGNETIC LOCK FOR HAZARDOUS LOCATIONS
© 2018 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comIS171HD
PCN18041
R10-18GR
See Figure 1 elevation profiles to determine mounting application
requirements for each individual application.
Note: A 2-1/2” (64mm) reveal is required to assure rigid mounting of
the RCI 171HD magnetic lock assembly.
1. Mark door according to armature template and dimensions on
reverse side.
2. Drill and prep holes in door per armature template on reverse
side.
3. Gently tap (2) 3/16” (5mm) diameter spring pins into rear side of
armature(s).
4. Insert one (1) spring washer over 5/16”-18 special shoulder
screw, insert the screw through the armature.
Add three(3) conical spring washers and one (1) flat washer over
the shoulder screw.
Carefully apply thread locking compound to exposed thread.
See Figure 2 details for each type of installation.
All parts must be assembled properly before installing the
armature to the door.
Install complete armature assembly on the door per Figure 2
detail.
5. Tighten shoulder screw securely with allen wrench.
(Do not overtighten.)
Note: All armatures are normally equipped with a permanent magnet on
one end. Be certain to install armature so magnet lines up with magnet
switch inside housing of magnetic lock assembly. See Figure 3.
6. Mark frame per magnetic lock template and dimensions on
reverse side.
7. Remove housing cover of Magnetic Lock Assembly.
8. Drill and prep frame per “D” of Magnetic Lock template.
Attach Magnetic Lock Assembly to the frame using either (2) #14
sheet metal screws or (2) 1/4”-20 machine screws and external
tooth lock washers.
Tighten only enough to hold the unit in place.
(If filler plate is used, assure thet the screws go through both the
filler plate and the door frame.)
9. Drill 7/8” (22mm) diameter hole through filler plate and frame
per template for wire harness.
10. Make all electrical connections per Electrical Specifications box
on page 2. Use wire nuts, crimp connectors or solder to assure
good connections.
11. Energize Magnetic Lock Assembly; Adjust assembly so door is
snug against door stop, tighten (2) preliminary screws securely.
12. De-energize system.
Using mounting plate as a template, drill #21 drill and tap for
10-32 screws (minimum (2) places).
Carefully apply thread locking compound to exposed threads.
See Magnetic Lock template.
Install screws and tighten securley.
Re-energize system, recheck alignment of Magnetic Lock
Assembly to Armature by opening and closing door(s).
13. Install Magnetic Lock housing cover.
Pre-Installation Instructions
IMPORTANT! Read thoroughly before attempting installation.
Do not damage or mark magnetic lock or armature face - may
reduce holding efficiency.
This product is intended to be used in Class I Division 2 hazardous
locations. The following guidelines must be observed to reduce the
risk of fire explosion.
All national and local codes must be followed in the installation of the
magnetic lock assembly. For code interpretation, consult a local code
authority
This unit must be connected to an NEC (National Electric code, NFPA
70) Class 2 Supply. Operating temperature for the magnetic lock will
not exceed 185 F (85° C). Maximum ambient temperture is not to °
exceed 104° F (40° C).
For supply connections, use a suitable wire with a mimimum insulation
temperature rating of 167° F (75° C)
To reduce the risk of the ignition of hazardous atmosphere, disconnect
the magnetic lock assembly from the supply circuit before opening
the magnetic lock housing. Keep the unit properly sealed while in
operation. To reduce the risk of fire or explosion, do not install the unit
where the operating temperature exceeds the ignition temperature of
the hazardous atmosphere.
This unit is intended to be used in the following atmospheres;
Acetone, Ammonium Hydroxide, ATSM fuel C, Benzene, Methyl-
Ethylketone, Diethyl-Ether, 2-Nitropropane, Ethyl-Acetate, Furfural,
Normal Hexane, Methyl Alcohol
The product should be installed in a location that will not hinder or
create a potential safety hazard to authorized personnel accessing the
protected area.
Because electromagnetic locks are used in a variety of applications
and different door frame configurations, an experienced installer with
knowledge of this product must make a determination of the optimal
mounting method for this specific application.
Do not install this product on the exterior of buildings.
Do not use as a doorstop. This will void warranty.
NOTE: It is highly recommended that thread locking compound
be applied to all screws during installation to reduce chance of
screws loosening over extended time.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
Use with Underwriters Laboritories Listed (ULC/UL) compatible power supply
2
Inspection and Maintenance
This product and all related accessories or parts must be inspected and maintained on a . Contacting surfaces of the quarterly basis
electromagnetic lock and armature plate must be kept free of contaminating materials. Surfaces must be cleaned periodically with a
non-abrasive cleaner.
All mounting fasteners must be inspected on a . When properly installed, the ends of the armature plate allow a slight quarterly basis
movement but the plate will feel secure when grasped at the bolt. There should be no movement to the mounting bracket or housing of
the electromagnetic lock.
For added safety, thread locking compound has been provided for the armature plate bolt and the electromagnetic lock mounting
screws.
MAGNETIC LOCK LOCATION
ARMATURE LOCATION
A B
C
NOTE: SPRING PINS SHOULD FLOAT FREELY INSIDE OF HOLES.
.250 (6 mm) DIA.
3/4" (19 mm) DEEP
(2) PLACES
1-3/8" REF. (35 mm)
1-13/16"
REF. (46 mm)
1-1/4" (32 mm)
3" (77 mm)
7" (179 mm)
3" (77 mm)
7" (179 mm)
5-13/16" (148 mm)
6-11/32" (161 mm)
C
L
L
C
BOTTOM EDGE OF STOP
FACE OF DOOR
LATCH EDGE OF DOOR LATCH EDGE OF DOOR
BOTTOM EDGE OF STOP
E
D
FACE OF DOOR
E
D
F F FF
D. Drill for No. 14 sheet metal screws or drill and tap
for 1/4"-20 machine screws.
E. 1/2-14 NPT, Drill 7/8" (22 mm) DIA. hole thru ller
(if used) and frame in either of locations marked
(E) for rigit conduit containing wiring harness.
Use ller plug in location not used.
F. Using actual Magnetic Lock as template, drill
and tap per STEP 12 of installation instructions.
A. For THRU BOLT mounting in hollow metal
door(s) drill 11/32" (9 mm) DIA. hole thru door,
enlarge hole in outside face to 1/2" (13 mm) DIA.
B. For THRU BOLT mounting in solid core wood
door(s), drill 11/32" (9 mm) DIA. hole thru door(s),
enlarge hole in outside face to 1/2" (13 mm) DIA.
1" (25 mm) deep.
C. For REINFORCED DOOR (Minimum 3/8" (10 mm)
thickness) drill and tap thru reinforcement for
5/16-18 screw.
2AA
SHOULDER SCREW
SEX NUT ARMATURE
SPRING WASHERS
FLAT WASHER
NOTE: FOR MACHINE SCREW MOUNTING; REINFORCEMENT AND STRUCTURING ARE REQUIRED TO WITHSTAND A 1200 LB (544 KG) LOAD.
CLEARANCE HOLES FOR FILLER PLATE TO BE SPOTTED AT JOB SITE. CAUTION: "DO NOT ATTACH MOUNTING PLATE TO FILLER PLATE ONLY!"
ELECTRICAL SPECIFICATIONS:
CURRENT DRAW: 0.50 AMPS @ 12 VDC
0.26 AMPS @ 24 VDC
WIRE COLOR CODE: ORANGE/ORANGE (12VDC)
(NON-POLARIZED) RED/RED (24VDC)
HOLDING FORCE: 1200 LB (544 KG)
C
L
L
C
*NOTE: NOT TO SCALE
ARMATURE MOUNTING TO DOOR(S) FIGURE 2
FIGURE 2C REINFORCED DOOR
FIGURE 2A HOLLOW METAL DOOR
MAGNETIC LOCK MOUNTING TO FRAME FIGURE 1
FIGURE 1A STANDARD INSTALLATION
FIGURE 1B
with an FP-178 FILLER PLATE ACCESSORY
FIGURE 1C
with an AB-179 ANGLE BRACKET ACCESSORY
WIRING FOR D.P.S (DOOR POSITION SWITCH).
DRAWING SHOWS DOOR
IN OPEN POSITION
D.P.S.
MAGNETIC
LOCK
HOUSING
MAGNET
ARMATURE
WHITE (N.O.)
BLACK
(COMMON)
RED (N.C.)
D.P.S. CONTACT RATING
0.1 AMP @ 30 VDC MAX.
FIGURE 3
C
L
FIGURE 2B WOOD DOOR
7/8"
(22 mm)
1-3/4" REF.
(45 mm)
1-1/4" (32 mm) 2-1/4"
(57 mm)
C
L
REINFORCMENT BY OTHERS
(3/8" (10 MM) MIN.) TYPICAL
L
C
FILLER
PLATE C
L
ANGLE BRACKET RQ'D.
NOTE: units are voltage specic


Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: RCI 171HD

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba RCI 171HD benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-