Dormakaba PIL-M02 Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Dormakaba PIL-M02 (2 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war fĂĽr 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
Exit Lane Breach Control
Product advantages
• Provides a secure exit lane without
the use of a guard.
• ROI is potentially 18 months or less.
• Advanced Smart Technology.
• 3D imaging tracks activity.
• Highly sensitive sensors detect
breach attempts, suspect persons,
and objects.
• Configurable security zones to meet
airport security requirements.
• Minimal energy consumption (drive
units and LED lighting).
• High degree of modularity.
• No top access needed: controls
integrated in side wall.
• Sensors independent of ambient
light conditions and floor design.
• Open ceiling (easy integration into
sprinkler and smoke detection
systems).
PIL-M02 16
One Way Corridor
Entrance systems
Installed in an airport
terminal, dormakaba’s
Exit Lane Breach Control
(ELBC) corridor offers
controlled access and
secured single direction
pedestrian flow from the
air to land side.
The technology is designed to provide
an alternative to security guards, while
improving the monitoring, alerting,
notification, and isolation process for
faster response to potential intruders.
The modular system consists of a
combination of several fast-moving
full- and half-height door sets. The
required security level may be achieved
by different unit lengths and sensor
combinations. The sophisticated sensor
system ensures a high object security
with simultaneous regard to pedestrian
safety.
Construction
• Modular system (different lengths,
widths, and door combinations)
• Sensor-controlled corridor for passage
in one direction only, consisting of:
- 1 to 3 full-height doors (double
swing doors).
- 1 or 2 half-height swing doors (fast
moving low-energy barriers creating
an additional obstacle in case of a
security breach attempt).
- Safety glass.
- Audio and visual displays.
- Low-energy drive concept.
- Swing range monitoring by light
curtain at foot level.
- Transparent glass sidewalls.
- Kick plates to protect against
bumping.
- Multiple inputs and outputs
available for total control of the
unit.
Subject to change without notice
Dimensions
Standard unit (2 full-height
doors, 1 half-height door)
Passage width:
- 44-1/8" (1120)
Passage height:
- 82-11/16" (2100)
Total height:
- 98-7/16" (2500)
Total length:
Passage width:
- 36-1/4" (920) or
44-1/8” (1120)
Total length:
- 121-11/16" – 359-7/16"
(3091 – 9129)
depending on door
configuration.
Functions
• The exact interlock sequence
is project specific.
• The sensor system may be
adjusted for different levels
of security while maintain-
ing a high level of safety.
Power failure
• All full-height doors are
closed by buffer power.
• Can be configured for fail
safe or fail secure.
• All half-height doors are
freely movable.
• Pedestrians may leave the
corridor.
• Internal battery back up
system
Return of power
• Complete unit is initialized
automatically.
• Set operation mode is
resumed.
Pedestrian safety
• Door wing monitoring
prevents injury.
• Limited rotational energy
due to low energy drives.
• Complete system complies
with UL325
Object security
• Project-specific security
levels may be achieved by
different sensor levels,
corridor dimensions, and
door combinations.
Sensor systems
• 3D stereo sensors for
wrong way detection.
• Thrown object detection
for objects thrown into the
corridor.
• Presence detection for left
objects.
Electric system
Power supply
- 100–240 VAC, 50–60 Hz,
600 VA
- Controls integrated in side
walls.
Operating modes
• Normal free flow.
• Interlock.
• Blocked.
• Open.
• Cleaning.
• Maintenance.
Alarm schemes (with audio)
• Pre-alarm (suppressed) to
serve as a first deterrent.
• Full alarm in case of further
breach attempt.
• Thrown objects.
• Left objects.
Parameter settings
• Runtime monitoring of
sensors and drives.
• Acoustic alarm duration.
• Alarm reset (time-driven,
manually, automatic).
• Initialization time.
Installation
• On level finished floor.
Options
• Operating panel, optionally
with key switch.
• Remote operation via dry
contacts, LAN interface.
• Protection at ceiling level
against thrown objects.
dormakaba PIL-M02 One Way Corridor
EO 8.18
PIL-M02 Exit Lane Breach Control
dormakaba USA Inc.
2941 Indiana Avenue
Winston-Salem, NC 27105
844.SPECNOW
www.dormakaba.us
Note: Measurements are shown as
inches followed by millimeters;
for example, 1" (25).
Attention:
The top of the unit cannot bear loads!
Cross and
arrow symbol
Power supply
82-11/16" (2100)
92-7/16 )" (2348
97-3/16" (2468)
44-1/8" (1120) Power supply
Thr
own objects detec
Stereo sensor
Stereo sensor
Opening sensor
LED spot lights
LED spot lights
Landside
54-3/4" (1390)
59 5/-1 16" (1523)
43-5/16 43-5/16" (1100) " (1100)46-5/8" (1185)
260-1/16" (6606)
74-13/16" (1900)
9-13/16" (250)
9-1/8"
(232)
9-1/8"
(232) 41-3/4" (1060)
42 1)-3/16" (107
11-13/16"
(300) 27-3/16"
90)(6
18-7/16"
(469)
22-1/4"
(566)
22-1/4"
(566)
22-3/8"
(568)
20-1/2"
(520)
14"
(355)
27-3/16"
(690)
11-13/16"
(300) 14"
(355)
20-1/2"
(520)
Airside


Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: PIL-M02

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba PIL-M02 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-