(P/N) 723.069 Rev C
07/15
© copyright 2009-2015 Kaba Mas LLC
Page 1 of 2
OPEN LOCK WITH THE FACTORY
COMBINATION
LA GARD mechanical locks are shipped with
the factory combination of . Open using the50
OPENING Index:
4 x Turn dial to the LEFT (CCW) passing
“50” three times. Then stop exactly on the
number “50” the fourth time.
Turn the dial to the RIGHT (CW) until it
stops and the bolt retracts.
NOTE: Variations in the alignment of the dial ring during installation could cause
the Factory Combination of 50 to vary slightly, either up or down by one or
two numbers.
NOTE: If using the VisionGard Dial (2085 or 2090 Series) and a lock with the
factory combination, the lock will open on 47.
NOTE: When dialing a combination, if you passed the number on which you
intended to stop, you cannot reverse the dial to correct. The opening procedure
must be repeated from the beginning.
IMPORTANT NOTE: Change the combination before putting the lock into operation.
SET COMBINATION
To change the combination, you will need to know the existing combination
and have a LA GARD change key (P/N 1307).
CAUTION: When selecting a combination, choose a three number sequence
from 0 - 99. NEVER select numbers 0 to 20 as
the LAST NUMBER of the combination. This is
the “Forbidden Zone” and can cause the lock
to malfunction. For security purposes, do not
select a combination from personal data such
as birth date, phone number, etc. You also
should not share the combination. It is a secret.
1. Dial the existing combination using the
CHANGING Index. (Figure 1.)
2. STOP the dial on the third number of
the combination.
3. Insert the change key into the change key hole. (Figure 2.)
OPERATING & CHANGING INSTRUCTIONS
LA GARD MECHANICAL
Group 1, Group 2 & Group 2M Locks
Figure 1
Figure 2
(P/N) 723.069 Rev C
07/15
© copyright 2009-2015 Kaba Mas LLC
Page 2 of 2
NOTE: If the change key does not go in easily, the wheels are not aligned. Repeat
steps 1 - 3.
4. Turn the change key to the RIGHT (CW) one-quarter turn until the key
stops. (Figure 2.) Leave the change key in the lock while setting the
new combination.
5. Next turn the dial to the LEFT (CCW) at least four complete
rotations to clear the lock. The lock is now ready to accept the
new combination.
CAUTION: Do not spin the dial to clear the lock.
6. Set the new combination using the CHANGING Index:
EXAMPLE COMBINATION: 10-20-30
Turn the dial LEFT (CCW) passing the first number in the combination
(10) three times. Then stop exactly on the number “10” the fourth time.
Turn the dial RIGHT (CW) passing the next number in the combination
(20) two times. Then stop exactly on the number “20” the third time.
Turn the dial LEFT (CCW) passing the last number in the combination
(30) one time. Then stop exactly on the number “30” the
second time.
4 x
3 x
2 x
7. Hold the Dial to prevent movement and turn the change key to the LEFT
(CCW) one quarter turn.
8. Remove the change key. The new combination is now set.
ALWAYS perform the combination test with the safe door open! Test the new
combination several times using the opening procedure below.
OPEN LOCK WITH A SET COMBINATION
Dial the set combination using the OPENING Index.
EXAMPLE COMBINATION: 10-20-30
Turn the dial LEFT (CCW) passing the first number in the combination
(10) three times. Then stop exactly on the number “10” the fourth time.
Turn the dial RIGHT (CW) passing the next number in the combination
(20) two times. Then stop exactly on the number “20” the third time.
Turn the dial LEFT (CCW) passing the last number in the combination
(30) one time. Then stop exactly on the number “30” the second time.
Turn the dial to the RIGHT (CW) until it stops and the bolt retracts.
4 x
3 x
2 x
NOTE: When locking the safe, always turn the safe handle to the locked position (bolt
extended) before turning the lock dial four complete rotations to the LEFT (CCW) to
relock. If you notice any resistance, DO NOT force the dial to turn. This may cause
damage to the lock.


Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: La Gard 1985

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba La Gard 1985 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-