Dormakaba HSW-R Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Dormakaba HSW-R (15 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 27 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/15
HSW-R Installation Instructions
Track rail 72 x 75 mm
1. Ceiling substructure for track rail and installation of the track rail:
The track rail must be bolted over its entire length (including the stacking track area) to a correctly
aligned, longitudinally and transversely horizontal substructure (e.g. DORMA „UK“ substructure system).
The substructure should be designed to accommodate the total weight of all the panels both in the
stacking area and in the partition section.
The fixing point intervals for mounting the track rail to the substructure should be approx. 300 mm
along the straight sections and approx. 100 mm in the stacking area.
Caution: All the track joints must be provided with connection pins (a) in order to ensure a flush
transition between the track sections and thus smooth sliding panel operation. (Fig. 1)
a
DORMA-Glas 800.52.127.6.32 Stand/Issue 05/04 Seite/Page 1/15
Fig. 1
2. Preparing the floor (Fig. 2):
In the standard version, eccentric sockets are recessed into the floor as lock keeps.
A Drill hole 25 mm dia. 30 mm deep for eccentric sockets, plus 8 mm dia. hole for anchor plug. Align
eccentric socket (double eccentric) and tighten with centre screw.
B Insert eccentric socket in recessed channel section
a
b
30
ø 25
S8
DORMA-Glas 800.52.127.6.32 Stand/Issue 05/04 Seite/Page 2/15
Fig. 2
3. Installing the floor springs (Fig. 3):
A recess (see drawing) must be provided for the floor springs (DORMA BTS). This is eventually covered
with a stainless steel floor plate.
a) Recess for the double action end panel floor spring
b) Recess for the double action sliding panel floor spring
20
57
57
a
b
BTS 75 = 51-57
BTS 80 = 51-57
BTS 84 = 51-58
BTS 75 = 291
BTS 80 = 341
BTS 84 = 306
BTS 75 = 50
BTS 80 = 60
BTS 84 = 40
BTS 75 = 50
BTS 80 = 60
BTS 84 = 40
BTS 75 = 51-57
BTS 80 = 51-57
BTS 84 = 51-58 BTS 75 = 291
BTS 80 = 341
BTS 84 = 306
BTS 75 = 78
BTS 80 = 78
BTS 84 = 108
BTS 75 = 78
BTS 80 = 78
BTS 84 = 108
Fig. 3
DORMA-Glas 800.52.127.6.32 Stand/Issue 05/04 Seite/Page 3/15
Fig. 4
5. Track roller arrangement (Fig. 5):
Only one roller type is provided for all the panels. The arrangement of the guide rollers in the stacking
area inlet section is of critical importance.
A Roller block for straight-through section = high guide rollers (a) outside
B Roller block for entry into branch section = high guide rollers (a) inside
a
A B
a
Fig. 5
4. Glazing (Fig.4):
The aluminium frame is supplied ready assembled and surface treated.
In performing the glazing work, ensure compliance with the instructions and guidelines of the double
glazing manufacturer.

Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: HSW-R

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba HSW-R benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-