Dormakaba HSB-E08 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung fĂŒr Dormakaba HSB-E08 (2 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war fĂŒr 49 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
Subject to change without notice
79-1/8"
(2010)
79-1/8"
(2010)
35-7/16"
(900)
37-3/16"
(945)
HSB-E08
42-1/8"
(1070)
25-9/16"
(650)
HSB-E08 sensor barriers
Premium
Standard units HSB-E08
Note: Description of single unit
Interlock height 37-3/16" (945)
Interlock length 79-1/8" (2010)
Passage width 2-9/16" (650)
Total width 42-1/8" (1070)
ADA compliance 36" (915) width available.
Housing, base columns,
guiding elements
AISI 304 Ø2-3/8"(Ø60) stainless steel tube with 3/8" (10) toughened
safety glass panel and AISI 304 stainless steel handrail as well as
horizontaland vertical sensors mounted on the guiding elements.
Security Passage area monitored by enhanced sensor system with an optimized
installation length and arrangement (increased level of single passage
monitoring in both irections). Integrated sneak-by guard, detection of
children and luggage or rolling cases.
Barrier elements Two door leaves made of transparent polycarbonate, upper edge
35 7⁄16" (900).
Swinging area monitored by separation sensors.
Finish Stainless steel semi-gloss smooth finish.
Safety Low energy drive with energy content less than 1.18 lb/ft.
Function Type 2–power assisted motion; two servo-positioning drives/electrically
controlled in both directions.
Drives Integrated in the swing tube.
Operating modes Optical.
Normally closed.
Normally opened. (Barriers close on tailgate event.)
Electrical equipment Control system and power supply integrated in the unit.
Power supply 110 – 230 VAC, 50/60 Hz. 368 VA
Standby power
consumption
17 VA
Standard adjustment in
case of power failure
Door leaves move freely.
Installation Dowelled on finished floor level, FFL.
Not suitable for outdoor installation.
Protection classes Housing IP32, components conducting supply voltage IP42.
Premium units offer tailgating
monitoring. The enhanced
sensor system includes
luggage and child detection.
Entrance systems
dormakaba HSB-E08 sensor barriers
EO 8.18
HSB-E08
Installation drawings
dormakaba USA Inc.
Dorma Drive, Drawer AC
Reamstown, PA 17567
844.SPECNOW
www.dormakaba.us
for anchoring
for anchoring
handrail
2-3/4" (7 0)
5-1/8" (130)
4-5/16" (110)
1-3/8"
(35)
3- 16" 9/ (90)
2" (50)
area
Ø3-1/8" (Ø80)
for conduits
8"7/
(22.5)
flange plate
Ø5-1/2" (Ø140)
1-1/2"
(100)
conduit
1/2"
(12.7)
conduit
PW = 25-9/16" (650) 15) PW = 36" (9
35-7/16" (900)
12-5/8"
(320)
37-3/16" 45) (9
22-13/16"
(580)
5" (127)
PW = 36" (915)
5-1/8"
(130)
5-1/8" (130)
PW =
25-9/16" (650)
46-7/8" (1190)
79-1/8" (2010)
37" 40) (9
40-3/4" (1035) 30-15/16" (785)
41-3/4" (1060) 5-1/8"
(130)
89" (2260)
31-7/8" (810)
- 76 3/8" (1940)
inside
outside
35-7/16" (900)
1- 16" 9/ (40)
8-3/16 " (208)
37-3/16" 45) (9
25-13/16" (655)
79 ) -1/8" (2010
FFL
Note
Dimensions shown as inches
followed by millimeters; for
example, 1" (25).

Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: HSB-E08

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba HSB-E08 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂŒr -Kategorien-