INSTALLATION
DKPS-2A
POWER SUPPLY / RGER FOR CHA ACCESS CONTROL AND EGRESS DOORS
ISDKP S-2
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
19.
20.
21.
22.
This power supply should be installed i compliance with the National Electricaln
Code(NFPA 70) CSA C22.1, Canadian Electrical Code, Part 1 and all applicable
Local Codes. Installation t performed by suitably qualified technicalo be
personnel.
Description
The DKPS-2A is a power supply/charger that supplies a total of 2.5 amps
nominal continuous supply current at nominal 12/24VDC outputs. There are
4 outputs lock for Magnetic or door strike each with electronic over-current
protection @ 2 Amp. It is installed in a large mild steel metal enclosure capable
of accommodating two 7AH or 12AH lead-acid batteriesrechargeable
. These are
monitored Power Supplies for use in Access Control and Egress Doors.
Listed under UL294, CAN/ULC-60839-11-1 and CAN/ULC-S533.
Battery load test every 48hr.
Battery Charger test every 48hr.
Battery Reversal protection.
Low Battery indication at 11.40/22.80 Volts
Low Battery disconnec at 10.10/20.30 Volts.t
Automatic switch over to stand-by battery upon AC Failure.
Common “Batt.Fault” CMOS relay for all battery and charger fault.
CMOS relay output for AC failure within 60 seconds.
LEDs display on enclosure door (LEDs, Green, Yellow).
Common “Out Fault” CMOS relay for DC failure on any of the 4 outputs.
Battery charging leads included.
Board Dimension: 195mm x 110mm
Enclosure Dimension: 338mm x 448mm x 110mm.
AC input indication by Green LED. (LED on when AC i present). s
1. Input = 100-240VAC, 50-60Hz. 2.4A Max draw.
2. Output 2.5 Amps continuous supply current at Nominal 12/24 VDC
controlled outputs and one auxiliary output.
3. 4 Magnetic Lock or 4 Strikes outputs each, with electronic over-current
protection set at 2 Amp.
4. Built-in dedicated charger for lead acid or gel cell type sealed batteries.
5. Maximum battery charging current Amps1
6. Yellow LED for Battery Fault indication including charger failure monitor.
7. Battery 10 presence detection within seconds.
PART NO:DM2000 Ver.02
General Specifications:
© 20 ba da Inc20 dormaka Cana
www. .us • one: 1.80 . 0 • Fax: 8 2.9 5 • Edormakaba Ph 0.265 663 1. 00.48 79 -mail: sales_R @ .comCI dormakaba R01-20GB
1
Technical Specification:
Controlled Outputs(4)
Charging Current Max. 1Amp
Operating Temperature 0 deg.C to 49 deg.C
LED Indications
1. Green LED - AC indicator
a. On when AC present.
b. The normally closed (NC) AC Fault CMOS Relay activates(open) within 60
seconds after AC failure.
2. Blue LED – DC Power indicator
a. Powered directly from the power supply DC output and indicates output is
present. Blue LED will be OFF when no DC is present.
3. Yellow LED – Battery Charger and Fault indicator
a. The Yellow LED indicates various Battery Fault Conditions and Indication.
4. Red LED –Battery Test indicator.
a. The Red LED indicates a Battery test Failure or a Battery charger Failure in
eht eeS .snoitidnoC tluaF rehto etacidni ot DEL wolleY eht htiw noitcnujnoc
Fault Conditions and Indication Table for details.
5. Red Led on individual output indicator
a. There are 4 Red LEDs indicating that the outputs are ON when lit.
See the table Fault Condition.
Nominal 12 VDC or 24 VDC,
Max.13.80 VDC or 27.60 VDC, Min. 11.40 VDC or 22.80 VDC
Max. 500mA each
Auxiliary Output
Reset & Fire Trigger Input Max. Wire Resistance 100 ohm
Nominal 12 VDC or 24 VDC,
Max.13.80 VDC or 27.60 VDC, Min. 11.40 VDC or 22.80 VDC
Max. 500mA
Model Line Security
Performance Ratings
Product Type Destructive Attack Endurance Standby Power
Power Supply I I IV
UL 294 Performance Levels:
Model GradeProduct Type
Power Supply 3 (when used with 7AH battery)
4 (when used with 12AH battery)
III (when used with
7AH battery
IV (when used with
12AH battery
CAN/ULC-60839-11-1 Performance:
Grade Achievement
To achieve Grade 3 or 4 connects,
the Trouble AC & Battery Relay
Outputs to a Grade 3 or 4 Control
Unit.
2
DKPS-2A
DKPS-2A
OPEN
OPEN
OFF
OFF
OPEN
OFF
OFF
OPEN
OPEN
OPEN
OPEN
OFF
ON
ON
ON
ON
1 SEC ON/OFF
THREE FLASHES
REPLACED
BATTERY IS
REPEAT UNTIL
STOP 1 SECOND
5 RAPID FLASHES
60 SEC
WITHIN
OPEN
BATTERY LOW
RESET/REX TRIGGERED
WHEN FIRE/ACP TRIGGER
IS NOT ACTIVATED
Fire/ACP TRIGGER
ACTIVATED
OUTPUT 1-4 FAIL
AC FAIL
BATTERY TEST FAIL
BATTERY TEST OK
DISCONNECTED
BATTERY
OR NOT CONNECTED
BATTERY REVERSED
RELAY
RELAY
ACBATTRED LED 5YL GLLED-GFAULT
Relay Outputs:
Output Output Type Description
FORM C
28VDC 300mA, PF 1DRY CONTACT RELAY RATING:
FACP OR ACCESS CONTROL PANEL
TRIP WHEN FIRE ALARM IS GENERATED FROM
CMOS RELAY RATING: 30VDC 60mA 16 OHMS
CMOS RELAY RATING: 30VDC 60mA 16 OHMS
CMOS RELAY RATING: 30VDC 60mA 16 OHMS
ONE OF THE 4 OUTPUTS SHORTED OR OVERLOADED
BATTERY PROBLEM
NORMALLY CLOSED
OPEN = FAULT
NORMALLY CLOSED
OPEN = FAULT
TRIPS WITHIN 60 SEC. AFTER AC FAILS
OPEN = FAULT
NORMALLY CLOSED
FACP or ACP
STATUS OUTPUT
RELAY
DC FAIL
BATTERY FAIL
AC FAIL
Fault Condition & Indications:
RED LED
1 - 4
STATUS OUT
RELAY
RELAY
RELAY
RELAY
BATTERY
CHARGER FAULT ON OPEN
DC
RELAY
10 FLASHES
2 SEC STOP
REPEAT UNTILL
CHARGER OK
3


Produktspezifikationen

Marke: Dormakaba
Kategorie: Nicht kategorisiert
Modell: DKPS-2A

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dormakaba DKPS-2A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Dormakaba

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-