APPLICATION EXAMPLEBENEFITS
– Low latency connectivity for sensitive applications
– 8 or 16 RS-232 or soware selectable RS-232/422/485
serial ports
– Dual IPv4/IPv6 stack
– Easy-to-use Python development environment for
custom applications
– Tx/Rx LEDs per serial port
– Patented RealPort® technology for COM/TTY port
control/ management
– Web proxy support
– Per user access controls
– Dedicated console port
– Digi Remote ManagerSM support
– SSL/TLS and SSHv2 for added security
8 and 16 port terminal servers provide 232 only or 232/422/485
selectable serial connectivity for critical applications
ConnectPort TS 8/16 serial servers provide secure, easy RS-232
or RS-232/422/485 serial-to-Ethernet integration of virtually
any device into wired Ethernet networks. They are ideal for
use in a wide variety of demanding applications such as
automation, robotics control, centralized device monitoring
and management, data acquisition, and point-of-sale
applications requiring COM/TTY ports, serial tunnelling or TCP/
UDP functionality.
Enhanced access control, management and configuration
capabilities support key security requirements for critical
infrastructure and distributed systems. A built-in Python
environment enables application development and
customization at the device level, including full device
CONNECTPORT® TS 8/16
connection control, data manipulation and event based
actions.
The ConnectPort TS implements Digi’s patented RealPort
COM port redirection soware which provides local serial
port functionality. The ConnectPort supports both host-
initiated and device-initiated RealPort connection modes.
SSH, SSL, TCP and UDP connectivity are also supported to
each port.
Management of the device is possible through Digi Remote
Manager, web services, CLI and SNMP connectivity with mass
configuration and customization tools available to pre-
configure devices prior to deployment.
TERMINAL SERVERS
WITH DUAL
IPV4/IPV6 STACK
RS-232/422/485
SERVERFACTORY
Ethernet
CONNECTPORT® TS
Barcode
Scanner
Robotic
Arm
Overhead
Scanner
FACTORY AUTOMATION
PortServer®
TS
PortServer®
TS MEI
ConnectPort®
LTS 8/16/32
RealPort® Accessories
and Cables
SPECIFICATIONS
WWW.DIGI.COM
PERFORMANCE
MANAGEMENT HTTP/HTTPS, SSH or Telnet; Optional secure enterprise management via Digi Remote Manager
PROTOCOLS IPv4/IPv6, UDP/TCP, DHCP, Extended Telnet RFC 2217, Telnet, Reverse Telnet, SSH direct to serial port,
Modbus/TCP to Modbus protocol conversion support
SOFTWARE Patented RealPort COM port redirector (server initiated or device initiated); RFC 2217; Python support
STATUS LEDS Serial: Tx/Rx; Ethernet: Link/Activity, Diagnostic
DIMENSIONS (L X W X H) 4.15 in x 7.7 in x 1.3 in (10.5 cm x 19.6 cm x 3.3 cm) 17 in x 6.95 in x 1.62 in (43.18 cm x 17.65 cm x 4.1 cm)
WEIGHT 4.1 lb (1.86 kg) 5 lb (2.3 kg)
SECURITY HTTPS, SSL, SSL/TLS, SSHv2, FIPS 197, SNMPv2, PPP
INTERFACES
SERIAL
PORTS 8 RS 232 serial ports
MEI version: 8 RS 232/422/485 serial ports (soware selectable)
16 RS 232 serial ports
MEI version: 16 RS 232/422/485 serial ports (soware selectable)
THROUGHPUT Up to 230 Kbps per port
SIGNAL SUPPORT TXD, RXD, RTS, CTS, DTR, DSR, DCD, RI
ETHERNET
PHYSICAL LAYER 10/100 Base-T
DATA RATE 10/100 Mbps
MODE Full or Half duplex
USB
PORTS 2 ports @ .5A max per port
POWER REQUIREMENTS
POWER INPUT 9-30 VDC @ .8A max 100-240 VAC, 50-60 Hz, 0.4A
POWER SUPPLY
12 VDC power supply for 0° C to 60° C (32° F to 140° F) with locking
barrel connector included; Extended temperature power supply
available
Internal power supply, 100 to 250 VAC, 50-60 Hz
POWER CONSUMPTION Typical: 6W (500 mA @ 12 VDC)
Max: 12W (1A @ 12 VDC) Typical: 8W; Max: 15W
PRODUCT SURGE PROTECTION
(ESD)
4 kV burst (EFT) per EN61000-4-4; 2 kV surge transient per
EN61000-4-5
1 kV burst (EFT) per EN61000-4-4; 2 kV surge transient per
EN61000-4-5
ENVIRONMENTAL
OPERATING TEMPERATURE 0° C to 60° C (32° F to 140° F) 0° C to 55° C (32° F to 131° F)
STORAGE TEMPERATURE -35° C to 85° C (-31° F to 185° F)
RELATIVE HUMIDITY 5 to 95% (non-condensing)
ETHERNET ISOLATION 1500 VAC min per IEEE 802.3/ABSU X 3.263
SERIAL PORT PROTECTION (ESD) 15 Kv human body model
APPROVALS
SAFETY UL60950-1, EN/IEC 60950-1, CAN/CSA C22.2 No. 60950, CUL60950-1-03
EMISSIONS/IMMUNITY FCC Part 15 Subpart B Class A, EN55024, EN55022, Class B, AS/NZS CUSOR 22, EN61000-3-2 ,3
ConnectPort® TS 8
ConnectPort TS 8 MEI
1ETHERNET
USB
100-240 VAC
0.4A
50-60 Hz
RXTX
0.5A MAX/P ORT
PORT 1
PORT 2
2
RXTX
3
RXTX
4
RXTX
5
RXTX
6
RXTX
7
RXTX
8
RXTX
9
RXTX
10
RXTX
11
RXTX
12
RXTX
13
RXTX
14
RXTX
15
RXTX
16
RXTX
CONNECTPORT® 16 ANDTS
CONNECTPORT 16 MEITS
17 in
1.62 in
CONNECTPORT
® 8 ANDTS
CONNECTPORT 8 MEITS
4.15 in
1.3 in
ConnectPort® TS 16
ConnectPort TS 16 MEI
DIGI INTERNATIONAL WORLDWIDE HQ
877-912-3444 / 952-912-3444 / www.digi.com
DIGI INTERNATIONAL FRANCE
+33-1-55-61-98-98 / www.digi.fr
DIGI INTERNATIONAL JAPAN
+81-3-5428-0261 / www.digi-intl.co.jp
DIGI INTERNATIONAL SINGAPORE
+65-6213-5380
DIGI INTERNATIONAL CHINA
+86-21-50492199 / www.digi.com.cn
DIGI SERVICE AND SUPPORT / You can purchase with confidence knowing that Digi
is always available to serve you with expert technical support and our industry
leading warranty. For detailed information visit www.digi.com/support.
© 1996-2015 Digi International Inc. All rights reserved.
All trademarks are the property of their respective owners.
PART NUMBERS
FOR MORE INFORMATION
PLEASE VISIT WWW.DIGI.COM
DESCRIPTION
70002534 ConnectPort TS 16 MEI
70002535 ConnectPort TS 16 MEI (International)
70002388 ConnectPort TS 16
70002389 ConnectPort TS 16 (International)
70002323 ConnectPort TS 8
70002324 ConnectPort TS 8 (International)
70002329 ConnectPort TS 8 MEI
70002330 ConnectPort TS 8 MEI (International)
91001527
B1/915


Produktspezifikationen

Marke: Digi
Kategorie: Nicht kategorisiert
Modell: ConnectPort TS 16 MEI

Brauchst du Hilfe?

Wenn Sie Hilfe mit Digi ConnectPort TS 16 MEI benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Digi

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-