Delta Dore Tyxia RF 642 Bedienungsanleitung

Delta Dore Empfänger Tyxia RF 642

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Delta Dore Tyxia RF 642 (2 Seiten) in der Kategorie Empfänger. Dieser Bedienungsanleitung war für 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
• Carefully read these instructions prior to installation.
The unit must be installed in compliance with
current standards.
• Always switch off the mains before installing or
servicing the unit.
• Do not attempt to repair the unit yourself;
an after-sales service is available.
• Check that the fastenings are suited to the surface
to which the unit will be attached (plasterboard,
brick, etc.).
The diagrams provided are simplified for greater
clarity. Protections and other accessories required
by standards are not illustrated.
Standard and good practice must be complied with.
Connected or nearby equipment must not generate
excessive interference (directive 2014/30/EU).
www.deltadore.com
TYXIA RF 642
Wireless receiver - 1 channel
Presentation
1
Mounting
3
Connection to the heating
4
Pulse mode (remote control switch, garage door, electric gate)
7
Associating the receiver with a
transmitter thermostat
5
Associating the receiver with a
door/window opening detector
6
Location
2
TYXIA RF 642 may be used for two types of
application:
- Control of automatic devices: lighting, a garage
door or an electric gate,
- Heating control: associated with a transmitter
thermostat, it can be connected to a boiler or
used to control an electric heating system (via a
contactor).
Removing the cover
To remove the cover, push the
tab and lift the cover.
Attachment with screws
Mounted on a wall using the screws
and plugs supplied.
Connecting a boiler with thermostat input
Connect receiver terminals 3 and
4 to both terminals of the boiler
thermostat input.
If necessary, remove the shunt (electric wire)
connecting the two thermostat input terminals.
Connection
Operation on the TYXIA RF 642
Pressing the button on the receiver changes the
current state (on or off).
Operation with an associated TYXIA or
TYDOM transmitter
On the receiver, press the button until the LED
flashes (~3 seconds).
You now have two options.
Slow flashing: simple lighting mode
Quick flashing: pulse mode
Press the receiver button briefly to switch from
one rate of flashing to the other.
Select the quick flashing option.
On the transmitter, press and hold the o button
down for 5 seconds.
The button will light up, go out then light up again.
Release.
Check that the receiver’s LED is no longer flashing.
The transmitter o button is associated with
the receiver in pulse mode.
Mounting by double-sided
adhesive tape
Mounted on a wall using the
double-sided adhesive tape supplied.
Ensure that the surface on which the
tape is applied is thoroughly clean
before mounting.
Connection
To connect the control wires,
run the wires along the raceway
provided or by piercing the hole at .Ê
Refer to the section that deals
with your type of installation.
When the connection is made,
fit the cover and switch on the
current at the circuit breaker.
Connecting a boiler
without thermostat input
If the boiler does not have
a thermostat input, you can
directly control the circulator
located next to the boiler.
To control electric convectors, you MUST use
a power contact switch that
is suitable for the total power
to be controlled.
The receiver must be placed near the automated de-
vice control (electrical switchboard) or heating control
(burner or thermostat input for a boiler, electrical
switchboard when used with a contact switch).
To avoid interference with the radio transmission,
the antenna must be free from any metallic elements
(cables, electrical switchboard, metallic covers).
The receiver power supply must be provided through
an electrical cable connected to the 230 V mains.
Antenna
Button
Removable
cover
LED
1
2
1
Because of changes in standards and equipment, the characteristics given in the
text and the illustrations in this document are not binding unless confirmed by our
services.
N
L
230V
On the receiver, press the button until the LED
flashes (~3 seconds).
Put the transmitter into association mode
(see transmitter guide).
Check that the receiver LED is no longer flashing.
The receiver is associated with the transmitter.
When associated with the receiver, a door/window
opening detector can prompt the heating to switch
automatically to frost protection whenever a window
is opened, for example.
On the receiver, press the button until the LED
flashes (~3 seconds).
On the door/window opening detector, press the test
button.
Check that the receiver LED is no longer flashing.
The door/window opening detector is associated with
the receiver.
230V
Example of a boiler
terminal box
Boiler
Circulator Power supply
230V/50Hz
N
N
L
L
230V
N
Power supply
230V/50Hz
Convector(s)
Convector(s)
Power supply of the
contact switch coilr OR
Direct convector control
if power < 3000 W
contact switch (not
supplied) fitted in the
electrical switchboard
If the boiler has a clock input,
do not mistake it for the
thermostat input.
Remove the
shunt
Wires to be
connected to the
receiver
Entrée
thermostat
de la chaudière
IMPORTANT: To use the receiver in pulse mode, it
must be associated with a transmitter.
Power supply
230V
Remote
switch Control of an
opening (for
example : a gate
Le mode impulsionnel ne peut être commandé
qu’avec une touche o (TYXIA).
OU
(modification de l’état en cours)
Simple lighting mode
8
Connection
Operation on the TYXIA RF 642
Pressing the button on the receiver changes the
current state (on or off).
Inverting the relay contact position
During an On command: the relay closes.
During an Off command: the relay opens.
You can invert the operation of the relay by
pressing the relevant button on the receiver for about
10 seconds.
Command sent Contact Inverted Contact
ON ON OFF
OFF OFF ON
Simple lighting mode with an associated
TYXIA transmitter
The simple lighting mode can be controlled by a
TYXIA transmitter (transmitter switch, key ring remote
control, etc.)..
300 W
max.
Mains
230V
Contact
switch
For lighting, the maximum power controlled
directly is 300 W. Above 300 W, a contact
switch must be used.
ON
ON
ON OFFOR
Either is possible,
depending on the scenario
OFF
OFF
Each function of the receiver can record up to a
maximum of 8 associations (buttons, transmitters,
etc.).
Associate the button with the receiver
On the receiver, press the button until the LED fla-
shes (~3 seconds). You now have two options.
Slow flashing: simple lighting mode
Quick flashing: pulse mode
Press the receiver button to switch from one rate of
flashing to the other. Select the slow flashing option.
On the transmitter, press and hold the button
down for approximately 5 seconds.
The button will light up, go out then light up again.
Release.
Check that the receiver’s LED is no longer flashing.
The transmitter button is associated with the
receiver.
Associate the buttons with the
receiver
On the receiver, press the button until the LED fla-
shes (~3 seconds). You now have two options.
Slow flashing: simple lighting mode
Quick flashing: pulse mode.
Press the receiver button to switch from one rate of
flashing to the other. Select the slow flashing option.
On the transmitter, press and hold the and
buttons down together for approximately 5 seconds.
The buttons will light up, go out, then light up again.
Release. Check that the receiver’s LED is no longer
flashing.
The transmitter buttons and are associated
with the receiver.
Associate the button with the receiver
On the receiver,
set the appliance to the required status (e.g. light off),
then press the button until the LED
flashes (~3 seconds). You now have two options.
Slow flashing: simple lighting mode
Quick flashing: pulse mode.
Press the receiver button to switch from one rate of
flashing to the other.
Select the slow flashing option.
On the transmitter, press and hold the button
down for approximately 5 seconds.
The button will light up, go out then light up again.
Release.
Check that the receiver’s LED is no longer flashing.
The transmitter button is associated with the
receiver.
With an associated TYXAL detector
The simple lighting mode can be associated with a
TYXAL detector (opening, movement, technical fault,
etc.).
On the receiver, press the button until the LED
flashes (~3 seconds).
On the detector, press the Test key (emits a beep).
Check that the receiver’s LED is no longer flashing.
The detector is associated with the
receiver.
One button (scenario) can control different
receivers simultaneously (roller shutters, dimmer,
simple lighting, etc.).
Lights switch on
following detection
Lights switch on
following detection
Lights switch off 90
seconds after the last
following detection
Lights switch off at
the end of detection
OFF
OFF
ON
ON
The receiver can record up to a maximum of 8
associations (buttons, transmitters, etc.).
With an associated TYXAL control unit
The simple lighting mode can be associated with a
TYXAL alarm control unit.
On the control unit, enable the Maintenance mode
(see control unit guide).
On the receiver, press the button until the LED
flashes (~3 seconds).
Slow flashing:
ê Surveillance status transfer
- Light on when surveillance in the control unit is
activated
- Light off when surveillance in the control unit is
deactivated.
Quick flashing:
ê Optical alarm
- Light on for 1min. 30s. in case of alarm.
Press the button to switch from one rate of flashing to
the other.
Press the “Test” button of the control unit.
Check that the receiver’s LED is no longer flashing.
The control unit is associated with the receiver.
With a associated TYDOM transmitter
The simple lighting mode can be associated with a
TYDOM transmitter.
To associate the receiver with TYDOM devices,
please refer to the respective guides.
TYDOM 3xx telephone transmitter
TYDOM 3xx enables the ON/OFF feature
to be operated remotely.
Removing all associations with the
receiver
9Troubleshooting
10 Technical features
11
Press and hold the button.
The LED flashes after 3 seconds.
Keep holding down the button.
The relay reverses after 10 seconds and the LED no
longer flashes.
Keep holding down the button.
The LED flashes after 30 seconds; all the associa-
tions are removed.
Release the button.
You cannot associate a transmitter with your
receiver.
The maximum number of transmitters that can be
associated with a receiver function is 8.
Check that this number has not been reached.
Lights only come on for 1 second each time a
button is pressed.
Pulse mode is enabled.
Put the unit into simple lighting mode (refer to the
“Simple lighting mode” section).
The receiver does not recognize the command
from a transmitter.
The transmitter is not associated with the receiver.
The receiver is still in association mode.
The transmitter batteries are low.
No LED lights up on the receiver.
The receiver is not powered.
Check the receiver power supply line.
You want to associate the receiver again.
You must start by removing all the wireless
associations (pulse, simple lighting or roller
shutters mode)
Power supply: 230 V, 50 Hz +/-10%
Class II insulation
Consumption: 0.5 VA
Maximum power: 16 A 230 Veff Cos = 1 M
or 300 W max. for lighting control
Radio frequency 868 MHz (standard EN 300 220)
Wireless range 100 to 300 metres outside,
variable depending on the associated equipment
(the range can be altered depending on the
installation conditions and the electromagnetic
environment)
Number of transmitters that may be associated with
the receiver: 8 max.
Automatic action: type 1.C (brownout)
Operating temperature: -5°C to +50°C
Storage temperature: -10 to +70°C
Dimensions: 120 x 54 x 25 mm
Protection index: IP 44 - IK 04
Install in an environment with normal pollution
levels


Produktspezifikationen

Marke: Delta Dore
Kategorie: Empfänger
Modell: Tyxia RF 642

Brauchst du Hilfe?

Wenn Sie Hilfe mit Delta Dore Tyxia RF 642 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Empfänger Delta Dore

Bedienungsanleitung Empfänger

Neueste Bedienungsanleitung für -Kategorien-