Alarm Controller
· 16-channel local alarm input (expandable to 80 channels); supports NO/
NC detector, detector tamper, short circuit and mask alarm.
· 4 channel alarm outputs (expandable to 84 channels), along with forced
start/shutdown, auto control, and alarm linkage.
· Multiple zone types, such as instant zone, delayed zone, and 24-hour
silent zone.
· Alarm input/output port circuit protection.
· Supports fault alarms, including controller tamper alarm, keypad tamper
alarm, power failure alarm, battery failure alarm, battery undervoltage
alarm, PSTN offline alarm, network disconnection alarm, IP conflict
alarm, and MAC conflict alarm.
· 2-channel RS-485 ports; up to 32-channel keypads; printer connection.
· Emergency alarms, such as fire, medical and duress alarm.
· CID (Contact ID Protocol); reuses landline telephone port (personal call
requires customized PSTN hardware module).
· Configuration method includes keypad and web; quick configuration
guide; remote configuration and search.
· Up to 8 subsystems; single zone and subsystem arming/disarming;
arming/disarming with keypad, keyfob, IC card and other methods.
· Supports 3 alarm receiving center at the same time, supports 3 different
alarm reporting strategies.
· High-volume log search function.
· Remote update.
· Multiple device recovery methods.
· Two Ethernet ports and two wired alarm centers.
ARC2 Series | DHI-ARC2016C-V3
System Overview
Driven by its advanced control technology and powerful data
transmission capabilies, this series of alarm controller ensures the
reliable, stable running of the enre system. This high security series
supports being used locally, without networking, and being networked
to form a powerful security monitoring system. When used along
with professional alarm plaorm soware, it fully displays its powerful
networking and remote monitoring capabilies.
Technical Specicaon
Input/Output
Alarm Input 16 x channel local inputs (expandable to 80 channels)
Alarm Output 4 x channel local outputs (expandable to 84 channels)
Interface
Network Port 2 × RJ–45 10/100 self-adapve Ethernet ports
Telephone Line 1-ch PSTN
Keyboard 32 × LCD keypads
Remote Control 32 × ARA24-W2
Storage Battery 1 × port (battery: 12 VDC/7 Ah)
RS-232 1
Indicator Light 3 × funcon indicators
Button 1 × forced start buon; 1 × default jumper; 1 × factory
default jumper
Scene
It is suitable for security use in scenes, such as schools, shops, factories,
nancial elds, legal elds and smart communies.
RS-485 2 (keypad, expansion module, and printer)
Buzzer 1
Function
Tamper Alarm Controller tamper; housing tamper
Auxiliary Power Output 1 × 12 VDC, 1 A
Network Protocol TCP/IP, DHCP, stac IP
Remote Update Yes
Arm and Disarm Keypad; keyfob; IC card; web; plaorm
Log 20,000
Power Failure Protection
for Configured Parameters Yes
Search Remote Alarm
Event Yes
User Management 64 network users and 200 keypad users
Access Configuration Keypad; web
ARC2 Series | DHI-ARC2016C-V3
Search Conguraons; system logs; zone faults; system faults;
program versions
Language English, Russian, Lan American Spanish, and Arabic
General
Power Supply 100–240 VAC, 50/60 Hz
Power Consumption Idling: 5 W
Full load: 60 W
Operating Environment –10 °C to +55 °C (+14 °F to +131 °F)
10%–90% (RH)
Product Dimensions 275 mm × 74.8 mm × 275 mm (10.83" × 2.94" × 10.83")
(L × W × H)
Packaging Dimensions 375 mm × 155 mm × 312 mm (14.76" × 6.10" × 12.28")
(L × W × H)
Installation Wall mount
Net Weight 2.1 kg (4.63 lb)
Gross Weight 2.5 kg (5.51 lb)
Certifications FCC; CE
Ordering Informaon
Type Model Description
Alarm
controller DHI-ARC2016C-V3 Alarm controller
Accessories
(Optional)
DHI-ARK50C-R Alarm keypad (supports card)
DHI-ARK50C Alarm keypad
ARM708-RS Output module
ARM808-RS Input module
ARA58-P PSTN module
ARA58-G-EN 2G module
ARA58-F-EN 4G module
Installaon
Dimensions (mm [inch])
ARC2016C-V3
Alarm Controller
DSS PRO
Platform
16
ARK50C/ARK50C-R
Alarm Keypad
8 8
2
RS- 485
RS- 485
Rev 002.000 © 2022 Dahua. All rights reserved. Design and specifications are subject to change without notice.
The images, specifications and information mentioned in the document are only for reference, and might differ from the actual product.
www.dahuasecurity.com
Applicaon
Produktspezifikationen
Marke: | Dahua Technology |
Kategorie: | Alarm klingelt |
Modell: | ARC2016C |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Dahua Technology ARC2016C benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Alarm klingelt Dahua Technology
14 August 2024
10 August 2024
7 August 2024
1 August 2024
29 Juli 2024
29 Juli 2024
27 Juli 2024
27 Juli 2024
27 Juli 2024
25 Juli 2024
Bedienungsanleitung Alarm klingelt
- Alarm klingelt Hama
- Alarm klingelt Velleman
- Alarm klingelt Beurer
- Alarm klingelt Cresta
- Alarm klingelt König
- Alarm klingelt TFA
- Alarm klingelt Blaupunkt
- Alarm klingelt Lenco
- Alarm klingelt Abus
- Alarm klingelt Olympia
- Alarm klingelt Smartwares
- Alarm klingelt Hyundai
- Alarm klingelt MT Logic
- Alarm klingelt Sencor
- Alarm klingelt Nikkei
- Alarm klingelt Honeywell
- Alarm klingelt Globaltronics
- Alarm klingelt Ascot
- Alarm klingelt Xavax
- Alarm klingelt Monacor
- Alarm klingelt HQ
- Alarm klingelt X4-Life
- Alarm klingelt Delta Dore
- Alarm klingelt La Crosse Technology
- Alarm klingelt Oregon Scientific
- Alarm klingelt Electia
- Alarm klingelt Sonic Alert
- Alarm klingelt Vimar
- Alarm klingelt Pentatech
- Alarm klingelt Amplicom
- Alarm klingelt Gewiss
- Alarm klingelt Valcom
Neueste Bedienungsanleitung für -Kategorien-
30 September 2024
29 September 2024
6 September 2024
5 September 2024
3 September 2024
3 September 2024
31 August 2024
30 August 2024
30 August 2024
30 August 2024