STANDBY UPS SERIES
ST425 / ST625U / ST900U
USER MANUAL
FEATURES
1. Power On Switch
2. Power On Indicator (green)
3. Battery and Surge Protected Outlets
4. Full-Time Surge Protection Outlets
5. Circuit Breaker
6. USB Port to PC (except for ST425)
7. USB Charging ports (except for ST425)
8. Widely-Spaced Outlets
S
S
S
S
S
T
T
T
T
T
4
4
4
4
4
2
2
2
2
2
5
5
5
5
5
S
S
S
S
S
T
T
T
T
T
6
6
6
6
6
2
2
2
2
2
5
5
5
5
5
U
U
U
U
U
S
S
S
S
S
T
T
T
T
T
9
9
9
9
9
0
0
0
0
0
0
0
0
0
0
Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed
power protection, operation, and performance during the lifetime of the product. Please take a
few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifies your product’s warranty, confirms your ownership in the event of a product
loss or theft, and entitles you to free technical support. Register your product now to receive the
benefits of CyberPower ownership.
CAUTION! To prevent the risk of fire or
electric shock, install in a temperature and
humidity controlled indoor area free of
conductive contaminants. (Please see
specifications for acceptable temperature
and humidity range).
CAUTION! To reduce the risk of electric shock,
do not remove the cover. There are no user-
serviceable parts inside.
CAUTION! Hazardous live parts inside can be
energized by the battery even when the AC
input power is disconnected.
CAUTION! The UPS must be connected to an
AC power outlet with fuse or circuit breaker
protection. Do not plug into an outlet that is
not grounded. If you need to de-energize this
equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the
unit and unplug it from the AC power source
before installing a computer component.
CAUTION! To reduce the risk of fire, connect
only to a circuit provided with 20 amperes
maximum branch circuit over current protec-
tion in accordance with the National Electric
Code, ANSI/NFPA 70.
CAUTION! Not for use in a computer room as
defined in the Standard for the Protection of
Electronic Computer / Data Processing
Equipment, ANSI/NFPA 75.
CAUTION! Do not dispose of batteries in a fire.
The batteries may explode.
CAUTION! Do not open or mutilate batteries.
Released electrolyte is harmful to the skin and
eyes. It may be toxic.
DO NOT USE FOR MEDICAL
OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products
for life support or medical applications.
DO NOT use in any circumstance that would
aect operation and safety of life support
equipment, any medical applications or
patient care.
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock,
do not use with or near an aquarium.
Condensation from the aquarium can cause
the unit to short out.
DO NOT USE THE UPS
ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do
not use the unit on any transportation such
as airplanes or ships. The eect of shock or
vibration caused during transit and the damp
environment can cause the unit to short out.
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate your UPS.
PRODUCT REGISTRATION
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) User’s manual
(c) USB device cable (except for ST425)
DETERMINE THE POWER
REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged
into the outlet does not exceed the UPS
unit’s rated capacity (425VA/260W for
ST425, 625VA/360W for ST625U, and
900VA/500W ST900U). If the rated
capacities of the unit are exceeded, an
overload condition may occur and cause
the UPS unit to shut down or the circuit
breaker to trip.
2. There are many factors that can aect
the amount of power that your electronic
equipment will require. For optimal system
performance keep the load below 80% of
the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately
upon receipt. However, after receiving a
new UPS, to ensure the battery’s maximum
charge capacity, it is recommended that
you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge
feature. When the UPS is plugged into an
AC outlet, the battery will automatically
charge whether the UPS is turned on or
turned o.
2. With the UPS unit turned o and unplugged,
connect your equipment requiring battery
backup into the battery power supplied
outlets. Plug the other peripheral equip-
ment (printer, scanner, speakers) into the
full-time surge protection outlets.
DO NOT plug a laser printer, paper
shredder, copier, space heater, vacuum,
sump pump or other large electrical
device into the “Battery and Surge
Protected Outlets”. The power demands
of these devices will overload and possi-
bly damage the unit.
3. Plug the UPS into a 2-pole, 3-wire ground-
ed receptacle (wall outlet). Make sure the
wall branch outlet is protected by a fuse or
circuit breaker and does not service equip-
ment with large electrical demands (e.g.
air conditioner, refrigerator, copier, etc…).
The warranty prohibits the use of extension
cords, outlet strips, and surge strips.
4. Press the power switch to turn the unit on.
The Power On indicator light will illuminate
green and the unit will “beep” twice.
5. If an overload is detected, an audible alarm
will sound and the unit will emit one long
beep. To correct this, turn the UPS o and
unplug at least one piece of equipment
from the battery power supplied outlets.
Make sure the circuit breaker is depressed
and then turn the UPS on.
6. To maintain optimal battery charge, leave the
UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period
of time, cover it and store with the battery
fully charged. While in storage, recharge
the battery every three months to ensure
optimal battery life.
8. Ensure the wall outlet and UPS are located
near the equipment being attached for
proper accessibility.
9. Lay the UPS horizontally or use the key-
hole mounting slots to ax the UPS to
the wall in the proper orientation. DO NOT
stand the UPS up vertically.