Copyright © 2018 Cyber Power Systems, Inc. All rights reserved.
Automatic Transfer Switch
USER'S MANUAL
Table of Contents
Overview 1 .................................................................................
Model List 1 ...............................................................................
Product Contents 2 ..................................................................
For 1U Models 2 .............................................................................................
For 2U Models 3 ............................................................................................
Product Features 4 ..................................................................
Front/Rear Panel Description (1U 15A Models) 4 ............................
Technical Specifications 4 ........................................................................
Front/Rear Panel Description (1U 20A Models) 5 ...........................
Technical Specifications 5 .........................................................................
Front/Rear Panel Description (2U 30A Models) ..........................6
Technical Specifications 6 .........................................................................
Front/Rear Panel Description (2U 32A Models) 7 ...........................
Technical Specifications 7 .........................................................................
Installation Guide 8 ..................................................................
ATS PDU Configuration 8 ..........................................................................
Front Mounting 9 ..........................................................................................
For 1U Models 9 .......................................................................................
For 2U Models 10 ....................................................................................
Rear Mounting .......................................................................................... 1 1
For 1U Models .....................................................................................1 1
For 2U Models 13 ....................................................................................
Replacing LCD Panel 15 .............................................................................
Electrical Installation 15 .............................................................................
Power Cord Locking - For IEC Type ATS PDU 16 ............................
Input Power Cord 16 ..............................................................................
Output Power Cord 16 ..........................................................................
Network Installation 17 ...............................................................................
Operation 18 ..............................................................................
Remote Management 18 ............................................................................
Web ........................................................................................................18
Telnet and SSH 18 ...................................................................................
SNMP 18 .....................................................................................................
Local Management 18 .................................................................................
LCD Operation 18 ...................................................................................
LED Indicators 19 ....................................................................................
Environmental Monitoring (optional) 19 ........................................
Device Reset 19 .......................................................................................
Unattended/Automatic Shutdown 19 .............................................
Firmware Upgrade..............................................................20
ATS PDU 20 ..............................................................................................
LCD ...................................................................................................... 2 1
RMCARD 23 ..............................................................................................
Troubleshooting 25 .................................................................
Conformance Approvals 26 ....................................................
Customer Service & Warranty .......................................... 27
Appendix A-Hyper Terminal 28 .............................................
Appendix B-Power Device Network Utility 29 ....................
1
Overview
CyberPower Automatic Transfer Switches PDUs with dual input for power
provide redundant and increased reliability for critical devices with a single
power plug. Users can define the preferred input power source. When a
selected source is unstable or unavailable, the ATS PDU will switch to the
second power source to constantly provide power to connected devices. The
entire ATS PDU series are designed with LED and LCD interfaces for users
to easily observe power status and device load. On-site power management
is accomplished as users can configure power settings, via LCD interface,
according to local power condition. Available in both switched and metered/
monitored configurations, users have a broad base of options to select the
ATS PDU that best fits their needs.
WARNING: This automatic transfer switch has dual power cords (A & B) to
provide redundant power sources to devices with single power supplies and
can be plugged into separate compatible sources* to ensure continuous
access. Users select the preferred source as the primary input. CyberPower
Smart App Online and Sinewave series UPS are highly recommended for use
as the power source.
* Only sine wave AC power sources are compatible with this ATS PDU. Note:
Simulated sine wave AC power sources are NOT compatible.
Model List
Switched Series Metered/Monitored Series
1U 1U
PDU15SW10ATNET PDU15M10AT
PDU20SW10ATNET PDU20M10AT
PDU20SWT10ATNET PDU20MT10AT
PDU20SWHVT10ATNET PDU20MHVT10AT
PDU15SWHVIEC12ATNET PDU15MHVIEC12AT
PDU20SWHVIEC10ATNET PDU20MHVIEC10AT
PDU20SWHVCEE10ATNET* PDU20MHVCEE10AT*
2U 2U
PDU30SWT17ATNET PDU30MT17AT
PDU30SWHVT19ATNET PDU30MHVT19AT
PDU32SWHVCEE18ATNET* PDU32MHVCEE18AT*
*Selected models may not be available in certain regions. Please contact your
CyberPower sales team for more information.
Safety Precautions
Read the following before installing or operating the Automatic Transfer
Switches (ATS) PDU:
• Use only the supplied hardware to attach the mounting brackets.
• The ATS PDU must be plugged into a single phase three-wire, grounded
outlet on a circuit that is protected by a fuse or circuit breaker. For
PDU15xxxxx series, please use a 15A circuit protector. For PDU20xxxxx
series, please use a 20A circuit protector. For PDU30xxxxx series,
please use a 30A circuit protector. Connection to any other type of
power outlet may result in a electrocution hazard.
• Do not use extension cords or adapters with these ATS PDUs.
• Never install an ATS PDU or associated wiring or equipment during a
lightning storm.
• Ensure that the power cord, plug, and socket are in good condition.
To prevent the risk of fire or electrocution, this ATS PDU should
be installed in a temperature and humidity controlled indoor area
free of conductive contaminants. Do not install this ATS PDU where
excessive moisture or heat is present.
Before using, please check to ensure the package contains all the
items shown below. If there are missing parts, please contact your
local CyberPower sales team for technical support.
Check


Produktspezifikationen

Marke: CyberPower
Kategorie: Nicht kategorisiert
Modell: PDU20MT10AT
Gewicht: 5198 g
Produktfarbe: Schwarz
Stecker: NEMA L5-20P
AC Eingangsfrequenz: 50 - 60 Hz
Betriebstemperatur: 0 - 45 °C
Zertifizierung: UL60950_1 certified by ETL (USA), CSA C22.2 (Canada), FCC Class A
Display: LCD
Anzahl Ethernet-LAN-Anschlüsse (RJ-45): 1
Kabellänge: 3 m
Gehäusematerial: Metall
LED-Anzeigen: Ja
Temperaturbereich bei Lagerung: -15 - 45 °C
Luftfeuchtigkeit bei Lagerung: 0 - 95 %
Abmessungen (BxTxH): 433 x 236.22 x 44.45 mm
Nachhaltigkeitszertifikate: RoHS
Höhe bei Betrieb: 0 - 4000 m
Anzahl der AC-Ausgänge: 10 AC-Ausgänge
AC-Steckertypen: NEMA 5–20R
Stromstärke (maximal): 20 A
Nominale Eingang Spannung: 100 - 120 V
Nominale Ausgang Spannung: 100-120 V
Management-Plattform: SNMP/HTTP
Rack-Kapazität: 1U
Höhe bei Lagerung: 0 - 15000 m
PDU-Typen: Messgerät

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower PDU20MT10AT benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert CyberPower

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-