CyberPower MP1028WWR1 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für CyberPower MP1028WWR1 (1 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 45 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/1
YOUR ULTIMATE ALLY IN POWER
4-PACK: 8-OUTLET SURGEPROTECTOR
(6 OUTLETS & 2 USB PORTS)
MP1028WWR1
USER MANUAL
2
3
4
1
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
FEATURES
1. Surge Protected Indicator
Illuminated when the surge protection feature is
working properly.
2. Ground Indicator LED
Illuminated when the Ground protection feature is
working properly.
3. Pivoting Grounded Outlets (6)
Pivoting outlets for ease of use and convenience, fits
standard-sized plugs.
4. USB Charging Ports*
Connect and charge up to two (2) USB devices using the
surge protected USB charging ports.
*USB outlets cannot be used as a USB hub. This device
does not transfer data.
SPECIFICATIONS
Model Number: MP1028WWR1
Outlets: 6 Standard Outlets,
2 USB Charging Ports
Surge Protection: 1200 Joules
Electrical Rating: 125 V / 15 A / 1875 W
USB Charging Rating: 5 V / 2.4 A total
UL Clamping Voltage: UL 1449 3rd
400 V (H-N, N-G),
500 V (H-G)
Maximum Peak Current: 60,000 A
3 AC Lines Protected: H-N: 30,000 A,
H-G: 15,000 A,
N-G: 15,000 A
(The maximum surge possible on
household wiring is 6,000 volts)
Response Time: Less than 1 nanosecond
Attenuation: Up to 32 dB
EMI/RFI Filtration: 150 kHz to 100 MHz
i WARNING: This product can expose you to chemicals including bisphenol A (BPA)
and styrene (ABS), which is known to the State of California to cause reproductive
harm and cancer. For more information, go to www.P65Warnings.ca.gov..
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOTdaisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between
the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal
protection that will disconnect the surge protective component at the end of its
useful life, but it will maintain unprotected power to the load.
TROUBLESHOOTING
If the grounded indicator does not light when you plug in the surge protector,
move the surge protector to a dierent grounded three-prong AC outlet. If it
still does not light, return the product to the retailer for assistance. If the surge
protector appears to be working properly, your outlets may not be properly
grounded and need to be repaired by a professional electrician. If the grounded
indicator turns o after a period of use, the surge protection has been depleted.
Replace your surge protector.
If the protected indicator does not light, the surge protector’s AC lines are no
longer protected from surge. The surge protector may have received a power
surge or spike beyond its specified limits that overloaded the protection circuitry
and rendered it inactive. The surge protector has protected your connected
equipment as designed, but it will not protect against future surges, and spikes. It
should be replaced.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
• Product warranty
• Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
Hours of Operation: Monday - Friday: 7:00am - 6:00pm CST
© 2022 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.


Produktspezifikationen

Marke: CyberPower
Kategorie: Nicht kategorisiert
Modell: MP1028WWR1

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower MP1028WWR1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert CyberPower

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-