CyberPower DTC36U12V3-G Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr CyberPower DTC36U12V3-G (2 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war fĂĽr 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
User’s Manual for
CyberShield
DTC36U12V3-G
OVERVIEW
7
6
5
4
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack, install, or operate this device.
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CAUTION!
CyberShield UPSs are designed to provide a local power solution for
cable telephony, wireless local loop (WLL), and fiber to the home
(FTTH) broadband equipment. FTTx not only needs backup power
to prevent utility power failure, but also supports making emergency
calls (e.g., 911) for help.
The battery can energize hazardous live parts inside even when the AC input power
is disconnected.
Before replacing the battery, make sure the replacement has the same rating:
Certified Valve Regulated Lead Acid Battery, 12V, 7.2Ah maximum.
CAUTION!
To reduce the risk of electric shock, keep the cover on. There are no user-serviceable
parts inside the unit. Please contact us or our dealer for service.
Before replacing the battery, remove conductive jewelry, such as chains, watches and ,
rings. Use tools with insulated handles to avoid high energy, which could pass through
conductive materials and cause severe burns.
To avoid electric shock, unplug power cable from the AC power source before servicing
the battery or installing a computer component.
It is recommended to connect the unit to the required equipment and battery before
plugging in the utility power.
The UPS battery is charging when it’s connected to utility power. The battery is
charging during its first 24 hours of normal operation. Don’t expect full battery capacity
during this initial charging period.
The battery must be supplied by CyberPower. Using improper battery which is not
evaluated with this model could cause a risk and is at the user's own risk.
To store the UPS for an extended period, refer to the typical recharge time in the
specification and recharge the battery every three months to ensure battery life.
To reduce the risk of fire or electric shock, install in an indoor area that both temperature
and humidity could be controlled, and free of conductive contaminants. To find the
acceptable ranges of temprature and humidity, please refer to the specification.
Runtime is based on testing fully-charged and new batteries at normal operating
conditions. Runtime curve is approximate and varies based on battery age, level of
charge at test, environment, and other variables.
Number
Description
2
Alarm Silence Button
3
Cold Start Button
4
Cable Retainer Installation Point
5
Communication Cable Connector
6
AC Power Cable Connector
7
Battery Cover
1
LED Indicator
INSTALLATION
DESKTOP USE:
1.) Remove the battery cover at the back of the DTC36U12V3 and connect the battery wires.
2.) Connect the communication cable and simply place the DTC36U12V3 on or under a desk to
begin backing up the optical home network.
3.) Plug the AC power cable into wall outlet.
4.) DTC36U12V3 desktop placement is shown as OVERVIEW illustration.
Step 3:
Connect the AC cable to the wall outlet.
Step 2:
a. Connect the communication cable between the DTC36U12V3
and the ONT device.
b. Install the cable retainer to secure the commnication cable.
WALL MOUNT USE:
RECOMMENDED SCREW SIZE
Mounting Surface
1"~1.5"
1/8"
3/16"
5/16"
Step 1:
b. Place the screws into the wall using and required anchors for a secure installation.
c. Place the round portion of the keyhole slots of the unit over the installed mounting screws.
d. Connect the battery connector carefully, reinstall the battery into the unit and secure the strap.
a. Use the enclosed installation paper template to mark the location of the screw holes used to mount the DTC36U12V3 to the wall.
BATTERY REPLACEMENT
As long as utility power is on, you may leave the UPS and connected equipment while replacing a new
battery. (For service personnel reference only)
Step 1:
a. Slide off the battery cover
at the back of the unit.
Step 2:
a. Remove the battery from the enclosure.
b. Disconnect the battery cable connectors.
Step 3:
a. Replace with new battery and reconnect the
battery connector. Make sure the red wire
is connected to the “+” polarity, and the
black wire is connected to the “-” polarity.
b. Slide the battery back into the compartment
and cover the unit.
COLD START
BUTTON FUNCTIONS
The cold start feature is used when utility power is no longer present and a new or fresh
battery is installed to support the load device. Once the new/charged battery is installed,
depress the COLD START button until the 4 LED indicators light up.
Functions
Cold Start Press the COLD START button for 3 seconds.
Reset Output
Instructions
Temporarily Alarm
On/Off
Permanent Alarm
On/Off
Press the ALARM SILENCE button for 1 second to turn the alarm off
for 24 hours. A short beep will occur to confirm the alarm is off.
Press the
ALARM SILENCE
button for 15 seconds to turn the alarm off
for permanently. A short beep will occur to confirm the alarm is off.
Press the ALARM SILENCE button for 1 second again to restore the
alarm. Two short beeps will occur to confirm the alarm is on.
Press the
ALARM SILENCE
button for 15 seconds again to restore the
alarm. Two short beeps will occur to confirm the alarm is on.
Press the
ALARM SILENCE
button for 20 seconds to turn off the
output power, and it will turn on automatically after 15 seconds.
CAUTION! The means of power cord should be connected to a socket-outlet with earthing connection.
1
2
3
AC Inlet
Communication signals
DTC36U12V3
Pin 7
Indicator Color Light on
DC
BATTERY
SYSTEM
STATUS
MUTE
Green
Green
Orange
Red
LED STATUS INDICATION
Normal operation
Light off
System fault
(Output off)
Battery mode Utility mode
Blinking
Permanent alarm off Alarm on Temporarily alarm off
Replace battery/
Battery missing
Low battery
Battery OK N/A
N/A
COMMUNICATION SIGNALS
The communication signals of this unit are isolated from the internal circuitry via open collector
optocoupler transistors. The connection “SIG RTN” (Signal Return) is a return point for all
communication signals. In the typical application, the connected equipment digital ground
connects to Signal Return, and pull-up resistors turn the open collector signals into logic levels.
12V
12 V R T N
RTN
ON BATTERY
BATTERY MISSING
REPLACE BATTERY
LOW BATTERY
Signal return
Low when the UPS is in utility mode.
Low when battery has sufficient capacity.
Open when the battery’s capacity is low.
SignalPin Message
1
2
3
4
5
6
7
Low when battery is present.
Open when battery is missing or needs to be replaced.
12 Volt power return
Open when the UPS is in battery mode.
+ Voltage output
SIG
Low when the battery is in a normal state.
Open when the battery needs to be replaced.
SPECIFICATION
Input
Voltage Range
Frequency Range
Output
On Battery Output Voltage
12 Vdc
Continuous Power Capability
36 W
≥ 80%
Battery
Battery Type
Sealed, Maintenance Free Lead-Acid Battery
Numbers of Battery
12 Vdc / 7.2 AH x 1
Typical Recharge Time
14 hours
Yes
Replaceble
Surge Protection and Filtering
Lightning / Surge Protection
Yes
Management
Auto Charge
Yes
cPhysi al
Dimensions (L*W*D)
16.8 cm x 8.1 cm x 18.5 cm
Weight (with battery)
3.13 kg
Environment
Operating Temperature
- 4ÂşF
–
113ÂşF
Operating Humidity
0 – 95% noncondensing within enclosure
Max Operating Elevation
10,000 ft (3,048 m)
Max Storage Elevation
50,000 ft (15,240 m)
Storage Temperature
(-20
ÂşC
–
45ÂşC)
100 Vac
–
240 Vac
50
–
60 Hz
Efficiency (at Full Load, 25°C)
(25°C)
Maximum Full Charge Time (25°C)
DTC36U12V3Model
36 hours
- 4ÂşF
–
113ÂşF
(-20
ÂşC
–
45ÂşC)
For more information, please contact:
CyberPower Systems ( USA ), Inc. 4241 12th Avenue East, Suite 400, Shakopee, MN 55379 Phone: (952)403-9500 Fax: (952)403-0009 cyberpowersystems.com
CyberPower Systems ( EUROPE ), Inc. Flight Forum 3545, 5657DW Eindhoven, The Netherlands E-mail: sales@cyberpower-eu.com eu.cyberpowersystems.com
K01-3612009-02
WARNING: Cancer and Reproductive Harm-
www.P65Warnings.ca.gov.
LIMITED WARRANTY
The Limited Warranty is governed by the laws of the United States and the State of Minnesota, without reference to conflict of law principles. The application of the United Nations Convention of Contracts
for the International Sale of Goods is expressly excluded.
FCC NOTICE
CAUTION: Shielded signal cables must be used with this device to ensure compliance with Class B FCC limits.
CAUTION: Any changes or modifications which are not expressly approved by CyberPower could void the authority granted by the FCC to operate this equipment.
All rights reserved. Reproduction without permission is prohibited.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or
relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
(4) Consult the dealer or an experienced radio/TV technician for help.
CAUTION: Batteries are considered HAZARDOUS WASTE , so they must be disposed of properly.
Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by local regulations.
CAUTION: CyberPower Systems encourages environmentally sound methods for disposal and recycle of its UPS products.
Please dispose and/or recycle the UPS in accordance to the local regulations of your state.
CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years from the date of original purchase, subject to the terms of this Limited
Warranty. This Limited Warranty gives you specific rights, and you may have other rights, which vary from State to State and Province to Province.
Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose, if applicable to the Product, is limited in duration to three years. This provision shall NOT create any Implied Warranty or
Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product. NOTE: Some States and Provinces do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you.
To be covered, you must be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty. Your sole and exclusive remedies are those provided by this Limited
Warranty. This exclusion of other express warranties applies to written and oral express warranties. CyberPower excludes any liability for personal injury. CyberPower excludes any liability for direct, indirect,
special, incidental, or consequential damages, whether for damage to or loss of property, loss of profits, business interruption, information or data. This exclusion applies even though damage or loss is
caused by negligence or other faults. NOTE: Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to
you.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.
CyberPower does not sell the Product for use in high-risk activities. The Product is not designed or intended for use in hazardous environments requiring fail-safe performance, including the operation of
nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life support or medical applications or for use in any circumstance in which the failure of the Product could
lead directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical or life support device (collectively, "High Risk Activities").
CyberPower
expressly disclaims any express or implied warranty of fitness for High Risk Activities. CyberPower does not authorize the use of any Product in any High Risk Activities. ANY SUCH USE IS IMPROPER
AND IS A MISUSE OF A CYBERPOWER PRODUCT.
Pin 1


Produktspezifikationen

Marke: CyberPower
Kategorie: Nicht kategorisiert
Modell: DTC36U12V3-G

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower DTC36U12V3-G benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert CyberPower

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-