Crestron Electronics, Inc. Installation Guide - DOC. 7687A
15 Volvo Drive Rockleigh, NJ 07647 (2041540)
Tel: 888.CRESTRON 12.14
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
As of the date of manufacture, the TST-600-DS, TST-600-DSW, and TST-600-IMCW have been tested and
found to comply with specifications for CE marking.
Crestron TST-600 and TST-602
Accessories
Installation Guide
INTRODUCTION
This document provides installation instructions for accessories that ship with either the
TST-600 and TST-602 Wireless Touch Screens or the TST-600-WALL and TST-602-WALL
Wall Mount Wireless Touch Screens.
For installation instructions, refer to the section for each of the following accessories:
• TST-600-DS
• TST-600-DSW
• TST-600-FP and TST-600-FP-NB
• TST-600-IMCW
TST-600-DS INSTALLATION
The only connection to the TST-600-DS is via the fixed cable, which is connected to the TO
PANEL port on the (included) TST-600-IMCW Interface Module.
When connecting the TST-600-DS to the TST-600-IMCW, consider the following:
• Use Crestron® power supplies for Crestron equipment.
• The included cable cannot be extended.
Hardware Connection from the TST-600-IMCW to the TST-600-DS
To TO PANEL
Port on
TST-600-IMCW
NOTE: The length of the connecting cable on the TST-600-DS is 9 feet (2 3/4 meters).
The length of the cable has been shortened for illustrative purposes in the diagram above.
NOTE: The included cable mount ferrite bead, FBTH-2, should be placed on the cable
near the connector end.
1. Post-construction refers to framed walls with drywall hung.
2. Since the TST-600-DSW contains moving parts, mounting it to a stud offers more support and is
therefore highly recommended. Although Crestron offers the post-construction TST-600-DSW-WMKM
and TST-600-DSW-WMKT mounting options, a mouning option that is secured to a stud, such as the
TST-600-DSW-BB or TST-600-DSW-PMK, is highly recommended.
NOTE: There is also an international back box kit (TST-600-DSW-BBI) available for the
TST-600-DSW for installation in concrete and masonry. Refer to the TST-600-DSW-BBI
Installation Guide (Doc. 7454) at www.crestron.com/manuals.
If the TST-600-DSW-BB or TST-600-DSW-PMK is to be used and a TSW-600-DSW Docking
Station is not available, the installer can either leave the hole in the mounting surface open (if
permitted by local building codes) or attach the cover plate supplied with the mounting kit to
the mounting hole.
Installation
To install the TST-600-DSW, complete the following procedure in the order provided. The
only tool required is a #2 Phillips screwdriver.
CAUTION: Allow an air gap of at least 12 inches (305 mm) in the wall cavity above and
below the touch screen for heat dissipation.
NOTE: The TST-600-DSW has been optimized for mounting in 5/8” (~16 mm) drywall. A
thickness of 1/2” to 1” (13 to 25 mm) can be used without issue. Thinner or thicker drywall
causes issues with the installation of the product.
NOTE: The following steps are performed only after the TST-600-DSW-BB or
TST-600-DSW-PMK has been installed. It is assumed the TST-600-DSW-BB or
TST-600-DSW-PMK has been secured to the stud according to the instruction in the latest
installation guides (Doc. 7455 and Doc. 7453, respectively). It is assumed that drywall is in
place and a cutout for the TST-600-DSW and touch screen is made in the drywall.
The TST-600-DSW is shipped with the docking mechanism locked in its “back” position. In
order to make cable connections, the mechanism must first be unlocked so it slides to the
“forward” position. To do this, slide the release latch on the right side of the TST-600-DSW
upward to release the mechanism. The mechanism slides forward. To locate the release
latch, refer to “Undocking the Touch Screen.”
1. Remove the four screws holding the cover plate in place to gain access to the
connectors on the TST-600-DSW.
TST-600-DSW Installation (Cover Plate Removal)
Before mounting the unit into the wall, remove
the cover plate to access the connectors. Once
all cables are connected, replace the cover plate.
2. Hold the TST-600-DSW near the back box and connect the NET and LAN cables from
the back box to the ports on the back of the unit.
3. Replace the cover plate using the four screws from step 1.
4. Place the TST-600-DSW into the back box (or against the TST-600-DSW-PMK if using
this instead of the back box) and using the four supplied 06-32 x 1 1/2” screws, two at
the top and two at the bottom, to attach the TST-600-DSW to the back box as shown in
the following illustration.
Further Inquiries
To locate specific information or resolve questions after reviewing this guide, contact Crestron's True Blue Support at
1-888-CRESTRON [1-888-273-7876] or, for assistance within a particular geographic region, refer to the listing of
Crestron worldwide offices at www.crestron.com/offices.
To post a question about Crestron products, log onto Crestron’s Online Help at www.crestron.com/onlinehelp.
First-time users must establish a user account to fully benefit from all available features.
Future Updates
As Crestron improves functions, adds new features, and extends the capabilities of the TST-602-DS, TST-602-DSW,
TST-600-FP, TST-600-FP-NB, and TST-600-IMCW, additional information may be made available as manual
updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a
complete technical documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as
an “Addendum” in the Download column.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions:
(1) This device may not cause harmful interference and (2) This device must accept any interference received,
including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could
void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
â—Ź Reorient or relocate the receiving antenna
â—Ź Increase the separation between the equipment and receiver
â—Ź Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
â—Ź Consult the dealer or an experienced radio/TV technician for help
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
TST-600-DSW INSTALLATION
Supplied Hardware
The hardware supplied with the TST-600-DSW is listed in the following table.
Supplied Hardware for the TST-600-DSW
* Pre-construction refers to framed walls prior to hanging drywall.
1. These parts come with the TST-600-DSW-B-S (Smooth Black).
2. These parts come with the TST-600-DSW-B-T (Textured Black).
3. These parts come with the TST-600-DSW-W-S (Smooth White).
Mounting Options
The TST-600-DSW Docking Station and TST-600 or TST-602 Touch Screen install simply
and cleanly into existing or newly constructed wall with an assortment of pre- and
post-construction mounting options. All mounting options are sold separately from the touch
screen. Refer to the following table for a complete list of mounting options and respective
installation guides.
Pre-Construction Mounting Options for the TST-600-DSW and TST-600 or TST-602
PRE-CONSTRUCTION*
OPTION MODEL DOCUMENT NUMBER
Back Box Kit TST-600-DSW-BB 7455
Pre-Construction Mount Kit TST-600-DSW-PMK 7453
Mud Mount Kit (Accessory) TST-600-DSW-MMK 7457
Trim Mount Kit (Accessory) TST-600-DSW-TMK 7456
POST-CONSTRUCTION 1
OPTION MODEL DOCUMENT NUMBER
Wall Mount Kit - Mud TST-600-DSW-WMKM
2
7457
Wall Mount Kit - Trim TST-600-DSW-WMKT
2
7456
Post-Construction Mounting Options for the TST-600-DSW and TST-600 or TST-602 TST-600-DSW Installation (Secure to the Mounting Option)
5. Use the four supplied 04-40 x 3/16” flat head screws to attach the aesthetic plate to the
front of the TST-600-DSW mechanism.
6. Push the mechanism backward into the box until it locks in place exposing the screw
holes on the left and right sides. Refer to the following illustration.
7. Install the bezel, being careful to orient it with the IR window facing up. Refer to the
following illustration.
TS-600-DSW Bezel Installation
Screws (4)
06-32 x 1 1/2”
NOTE: Either the TST-600-DSW-BB or TST-600-DSW-PMK
must be installed before installing the TST-600-DSW into the wall.
Wall
Secure the aesthetic plate to the
docking station assembly with the
four (4) included 04-40 x 3/16” screws.
Aesthetic Plate
Install the bezel with the
IR window facing up.
Secure the bezel to the metal chassis box
using the supplies screws and washers.
Screws (4)
06-32 x 3/16”
with Nylon Washers
Wall
8. Use the four supplied 06-32 x 3/16” screws with washers, two on the left side and two
on the right side, to attach the bezel.
9. Dock the TST-600 or TST-602. Refer to “Docking the Touch Screen’’ for details.
DESCRIPTION PART
NUMBER QTY
Assembly, Bezel, with IR, Wall Dock, Black1 4504777 1
Assembly, Bezel, with IR, Wall Dock, Textured Black2 4507641 1
Assembly, Bezel, with IR, Wall Dock, White3 4507241 1
Silkscreen, Assembly, Metal, Plate, Aesthetic, Black1, 2 4505195 1
Silkscreen, Assembly, Metal, Plate, Aesthetic, White
3
4507217 1
Screw, 04-40 x 3/16”, Steel, Flat, Phil, Black
1, 2
2007145 4
Screw, 04-40 x 3/16”, Steel, Flat, Phil, Zinc
3
2007150 4
Screw, 06-32 x 1 1/2”, Steel, Pan, Phil 2007254 4
Mounting Screw, 06-32 x 3/16”, with Nylon Washer 4509330 4
Emergency Latch Release 4507211 1
Uninstalling the TST-600-DSW
If it is necessary to remove the TST-600-DSW after it has been installed, complete the
following steps in the order provided. The only tool required is a #2 Phillips screwdriver.
1. Undock the touch screen. Refer to “Undocking the Touch Screen” for details.
2. Push the TST-600-DSW mechanism backward into the box until it locks in place
exposing the screws securing the bezel on the left and right sides.
3. Remove the screws and washers, two from the left side and two from right side,
which secure the bezel and gently remove the bezel from the TST-600-DSW.
4. Remove the screws, two from the top and two from the bottom, which secure the
TST-600-DSW to the back box.
5. If necessary, secure and label the attached cables before disconnecting them from
the TST-600-DSW.
Hardware Hookup
Make the necessary connections as called out in the illustration that follows this paragraph.
Apply power after all connections have been made. When making connections to the
TST-600-DSW, use Crestron power supplies for Crestron equipment.
Hardware Connections for the TST-600-DSW
Docking the Touch Screen
To dock the TST-600 or TST-602, perform the following procedure.
1. Press the button located on the front of the TST-600-DSW to the right of the OPEN
docking fixture. The mechanism slides forward.
2. Position the touch screen onto the TST-600-DSW at a slight angle to latch the top
portion of the touch screen to the tab on the top of the docking fixture. When the top
portion is latched, move the bottom of the touch screen backwards so the touch screen
is flat against the docking fixture. Magnets on the docking fixture contact the metal
plates installed on the touch screen to secure the touch screen in place.
3. Push the touch screen backward, being careful not to touch the display screen, until
the TST-600-DSW mechanism locks into place and the touch screen is flush with the
TST-600-DSW bezel. When the mechanism locks into place, the tab on the bottom of
the docking fixture slides into the recess on the rear of the touch screen to secure it in
place.
Undocking the Touch Screen
In normal operation, the TST-600-DSW unlatches the touch screen electrically via the
control system program. The control system program defines the particular touch screen
button that will be used for unlatching. When the touch screen is unlatched, the docking
mechanism slides forward and the tab on the bottom of the docking fixture slides clear of the
recess on the rear of the touch screen. The touch screen may then be removed from the
TST-600-DSW by first pulling the bottom of the touch screen slightly forward and then lifting
the touch screen upward off the tab on the top of the docking mechanism.
If the touch screen cannot release from the TST-600-DSW, use the supplied emergency
latch release tool to undock the touch screen with the following procedure:
1. While standing directly in front of the TST-600-DSW, insert the emergency latch
release tool into the space between the right side of the touch screen and the
TST-600-DSW bezel, about 1” (25 mm) up from the bottom right corner, all the way to
the line marked on the tool. Refer to the following illustration.
2. Slide the emergency latch release tool upward to engage the release latch. The
TST-600-DSW mechanism slides forward and the tab on the bottom of the docking
fixture slides clear of the recess on the rear of the touch screen.
3. The touch screen can now be removed from the TST-600-DSW by first pulling the
bottom of the touch screen slightly forward and then lifting the touch screen upward off
the tab on the top of the docking mechanism.
Assy, Insert
TST-600-IMCW
Screws (2) 06-32 x 3/16”
Mounting Bracket
Hardware Hookup
Make the necessary connections as called out in the following illustration. Apply power after
all connections have been made. When making connections to the TST-600-IMCW, use
Crestron power supplies for Crestron equipment.
Hardware Connections for the TST-600-IMCW (Front)
TO PANEL:
Connect to TST-600-DS
Docking Station via 10-Pin RJ-50 Cable
(Provided with Docking Station)
PWR:
From DC Power Pack
Hardware Connections for the TST-600-IMCW (Rear)
LAN:
10BASE-T / 100BASE-TX
Ethernet to LAN 24 G:
24 Vdc Power Input
LAN:
10 BASE-T / 100 BASE-TX
Ethernet to LAN
NET:
24 Vdc Power Input
Using the Supplied Emergency Latch Release Tool Installing on a Level Surface
To prepare the TST-600-IMCW to be mounted onto a level surface, ensure the unit is
attached to the surface mount bracket, as shown in the following illustration.
TST-600-IMCW Bracket Mount (Exploded View)
Product warranty can be found at www.crestron.com/warranty.
The specific patents that cover Crestron products are listed at patents.crestron.com.
Crestron and the Crestron logo are either trademarks or registered trademarks of Crestron Electronics,
Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade
names may be used in this document to refer to either the entities claiming the marks and names or
their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron
is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2014 Crestron Electronics, Inc.
TST-600-FP AND TST-600-FP-NB INSTALLATION
Perform the following procedure to remove the existing bezel and install the new bezel onto
the touch screen. A #1 Phillips screwdriver is required. Refer to the illustration below.
1. Turn off the touch screen, and then slide the battery switch on the rear to the off (down)
position.
2. Place the touch screen face down on a clean, padded work surface.
3. Remove the four screws that secure the front bezel to the touch screen and return the
unit to its normal, face-up position. (Use care and hold the bezel against the touch
screen. If the bezel separates from the rest of the touch screen while rotating the unit
to its normal position, the internal parts of the touch screen may spill out.)
Rear View Showing the Battery Switch and Screw Locations
Screws Screws
UP
4. When the touch screen is in its normal, face-up position, unsnap the bezel and lift it
from the touch screen.
5. Position the new bezel over the exposed touch screen, ensuring the bosses line up
and mate with the enclosure.
6. Gently snap the tabs next to the screen near the volume control and the 5-way
thumbpad. Refer to the following illustration.
Snap the Tabs Near Volume Control and the 5-Way Thumbpad
7. Hold the bezel against the touch screen and carefully rotate the entire touch screen
onto its face once more.
8. Reinstall the four screws to secure the bezel to the touch screen. Tighten the screws,
being careful not to strip the threads.
9. Reconnect the power and then slide the battery switch on the rear to the on (up)
position.
Installing in a 1-Gang Box
To install the TST-600-IMCW in a 1-gang box, mount the unit into the box as shown in the
following illustration.
TST-600-IMCW in a 1-Gang Box (Exploded View)
TST-600-IMCW INSTALLATION
The TST-600-IMCW can be installed in a 1-gang box, it can be rack mounted, or it can be
mounted on any flat surface using the included mounting bracket.
Supplied Hardware
The hardware supplied with the TST-600-IMCW is listed in the following table.
Supplied Hardware for the TST-600-IMCW
DESCRIPTION PART
NUMBER QTY
Assembly, Insert, Black 4509271 1
Assembly, Insert, White 4509273 1
Metal Bracket, 16 GA CRS 2016054 1
Conn, Plug, 2-Pin, SKT, Single Row 2003574 1
Screw, 06-32 x 1”, Flat, Slot 2013235 2
Screw, 06-32 x 3/16”, Pan, Phil 2007203 2
Rack Mounting
The TST-600-IMCW can be mounted in a rack with other equipment using the four mounting
holes on the corners of the interface module as shown in the following illustration.
TST-600-IMCW Rack Mount (Exploded View)
Rack Mount Screws
(Not Included)
Rack Rail
Assy, Insert
TST-600-IMCW
WARNING: To prevent bodily injury when mounting or servicing this unit in a rack,
observe the following guidelines:
• When mounting this unit in a partially filled rack, load the rack from the bottom to the
top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting
or servicing the unit in the rack.
1-Gang Electrical Box
(Not Included)
TST-600-IMCW
Screws (2) 06-32 x 1”
Wall Plate
with Hardware
(Not Included)
Assy, Insert
Mounting Surface


Produktspezifikationen

Marke: Crestron
Kategorie: Nicht kategorisiert
Modell: TST-600

Brauchst du Hilfe?

Wenn Sie Hilfe mit Crestron TST-600 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Crestron

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-