To add or replace a DMB I/O blade, perform the following steps and refer to the
illustrations below.
1. Do either of the following:
• If adding an I/O blade, remove the slot cover of an unused input or output slot as
appropriate by loosening the two thumb screws.
• If replacing an I/O blade, disconnect all cables from the blade being replaced,
loosen the two thumb screws that secure the blade to the blade assembly, and
then slide the blade out of the slot.
2. Carefully insert the new blade into the guides at the top and bottom of the selected
slot until the blade is 1/4 inch from the fully seated position.
3. Align the two thumb screws of the blade with the corresponding holes in the blade
assembly, and then push the blade inward until it is fully seated and engages the
chassis backplane.
4. Finger-tighten the two thumb screws to secure the blade—do not overtighten the
screws.
5. Reconnect the cables to the blade.
Input Blade Installation (DM-MD64X64 Shown)
Output Blade Installation (DM-MD64X64 Shown)
Description
DMB blades occupy the DM-MD64X64 and DM-MD128X128 DigitalMediaâ„¢ switchers.
This document provides installation instructions for the following:
• Adding or replacing a DMB input/output (I/O) blade
• Replacing the DMB CPU blade
Adding or Replacing a DMB I/O Blade
DMB input blades occupy input slots 1 through 8 of the DM-MD64X64 and input slots
1 through 16 of the DM-MD128X128. DMB output blades occupy output slots 1 through 8
of the DM-MD64X64 and output slots 1 through 16 of the DM-MD128X128. Refer to the
following illustrations for slot locations.
DM-MD64X64 DMB I/O Blade Slots DM-MD128X128 DMB I/O Blade Slots
Additional Resources
Visit the product page on the Crestron® website (www.crestron.com)
for additional information and the latest rmware updates.
CAUTION: DMB I/O blades are susceptible to damage from electrostatic discharge
(ESD). Standard ESD precautions must be followed when handling the blades. Always
wear an ESD wrist strap that is connected to ground, and place blades on grounded
surfaces only.
NOTE: DMB I/O blades are hot swappable; therefore, the blades can be installed
without the need to shut down the DigitalMedia switcher.
Input Slots
1-8
Output Slots
1-8
-B-
Input Slots
1-16
Output Slots
1-16
Thumb
Screws (2)
Thumb
Screws (2)
Replacing the DMB CPU Blade
The DMB-CPU-64 blade occupies the CPU slot of the DM-MD64X64; the DMB-CPU-128
blade occupies the CPU slot of the DM-MD128X128. Refer to the following illustrations for
the location of the DMB CPU blade in a DM-MD64X64 and DM-MD128X128.
DMB-CPU-64 Blade in DM-MD64X64 CPU Slot
DMB-CPU-128 Blade in DM-MD128X128 CPU Slot
As of the date of manufacture, the DMB Series blades have been tested and found to comply with
specications for CE marking.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
CAUTION: Changes or modications not expressly approved by the manufacturer responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced radio/TV technician for help
To replace the DMB CPU blade, perform the following steps and refer to the illustration
below.
1. Disconnect all cables from the blade, loosen the two thumb screws that secure the
blade to the blade assembly, and then slide the blade out of the slot.
2. Carefully insert the new blade into the guides at the top and bottom of the CPU slot
until the blade is 1/4 inch from the fully seated position.
3. Align the two thumb screws of the blade with the corresponding holes in the blade
assembly, and then push the blade inward until it is fully seated and engages the
chassis backplane.
4. Finger-tighten the two thumb screws to secure the blade—do not overtighten the
screws.
5. Reconnect the cables to the blade.
CPU Blade Installation into CPU Slot (DM-MD64X64 Shown)
Crestron Electronics, Inc. Installation Guide - DOC. 7486D
15 Volvo Drive Rockleigh, NJ 07647 (2035927)
Tel: 888.CRESTRON 05.15
Fax: 201.767.7576 Specications subject to
www.crestron.com change without notice.
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
The DMB Fiber Series blades are class 1 laser products. They comply with safety
regulations of IEC-60825-1, FDA 21 CFR 1040 11 and FDA 21 CFR 1040 10.
WARNING: Visible and invisible laser radiation when open. Avoid direct exposure to beam.
NOTE: Plug the included dust cap into the optical transceiver when the ber optic cable is unplugged.
The product warranty can be found at www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at patents.crestron.com.
Crestron, the Crestron logo, and DigitalMedia are either trademarks or registered trademarks of
Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered
trademarks, and trade names may be used in this document to refer to either the entities claiming the
marks and names or their products. Crestron disclaims any proprietary interest in the marks and names
of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2015 Crestron Electronics, Inc.
CAUTION: The DMB CPU blade is susceptible to damage from electrostatic discharge
(ESD). Standard ESD precautions must be followed when handling the blade. Always
wear an ESD wrist strap that is connected to ground, and place the blade on a
grounded surface only.
DMB-CPU-64
Blade
-B-
DMB-CPU-128
Blade
Thumb
Screws (2)
Produktspezifikationen
Marke: | Crestron |
Kategorie: | Schalten |
Modell: | DMB-4K-I-C |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Crestron DMB-4K-I-C benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Schalten Crestron
6 September 2024
5 September 2024
1 September 2024
22 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
20 August 2024
20 August 2024
Bedienungsanleitung Schalten
- Schalten Asus
- Schalten Belkin
- Schalten Hama
- Schalten HP
- Schalten LogiLink
- Schalten Manhattan
- Schalten Nedis
- Schalten Philips
- Schalten SilverCrest
- Schalten Panasonic
- Schalten Brennenstuhl
- Schalten Clas Ohlson
- Schalten Cotech
- Schalten Profile
- Schalten ZyXEL
- Schalten Bosch
- Schalten Yamaha
- Schalten Powerfix
- Schalten CSL
- Schalten Eminent
- Schalten Linksys
- Schalten Netgear
- Schalten König
- Schalten PCE
- Schalten Renkforce
- Schalten Trotec
- Schalten Schneider
- Schalten Rex
- Schalten Kaiser
- Schalten Vivanco
- Schalten Abus
- Schalten Elro
- Schalten Smartwares
- Schalten Tesla
- Schalten Perel
- Schalten Nexa
- Schalten Tork
- Schalten GEV
- Schalten Goobay
- Schalten Lindy
- Schalten Tripp Lite
- Schalten Ansmann
- Schalten Mercusys
- Schalten Marmitek
- Schalten Honeywell
- Schalten TRENDnet
- Schalten TP-Link
- Schalten Kathrein
- Schalten Flamingo
- Schalten Alcatel
- Schalten Tiptel
- Schalten Black Box
- Schalten Alpine
- Schalten Techly
- Schalten Ebode
- Schalten Theben
- Schalten Vacmaster
- Schalten GAO
- Schalten Hager
- Schalten Behringer
- Schalten Omnitronic
- Schalten Monoprice
- Schalten Ecler
- Schalten Monacor
- Schalten Huawei
- Schalten JUNG
- Schalten Victron Energy
- Schalten Ei Electronics
- Schalten Edimax
- Schalten Totolink
- Schalten D-Link
- Schalten Sylvania
- Schalten Audiovox
- Schalten B-Tech
- Schalten QNAP
- Schalten SPC
- Schalten Speaka
- Schalten Digitus
- Schalten Sygonix
- Schalten DataVideo
- Schalten Lancom
- Schalten LevelOne
- Schalten Merten
- Schalten APC
- Schalten Eberle
- Schalten Cisco
- Schalten Delta Dore
- Schalten Grässlin
- Schalten Tenda
- Schalten CyberPower
- Schalten Boss
- Schalten IFM
- Schalten Intertechno
- Schalten Elation
- Schalten Ubiquiti Networks
- Schalten Kramer
- Schalten Aeon Labs
- Schalten Intellinet
- Schalten Eaton
- Schalten AV:link
- Schalten Hikvision
- Schalten Vemer
- Schalten PreSonus
- Schalten Planet
- Schalten EnGenius
- Schalten Finder
- Schalten Mikrotik
- Schalten Shimano
- Schalten Homematic IP
- Schalten Berker
- Schalten Dormakaba
- Schalten Emerson
- Schalten Generac
- Schalten Intermatic
- Schalten KlikaanKlikuit
- Schalten Mercury
- Schalten Paladin
- Schalten Provision ISR
- Schalten Robbe
- Schalten SEC24
- Schalten Steren
- Schalten Suevia
- Schalten AMX
- Schalten Triax
- Schalten WHALE
- Schalten Vimar
- Schalten Cudy
- Schalten Siig
- Schalten Electro Harmonix
- Schalten RGBlink
- Schalten Iogear
- Schalten StarTech.com
- Schalten Smart-AVI
- Schalten Dahua Technology
- Schalten PAC
- Schalten Gefen
- Schalten Avocent
- Schalten Legrand
- Schalten Atlantis Land
- Schalten CYP
- Schalten H-Tronic
- Schalten ATen
- Schalten Axing
- Schalten KanexPro
- Schalten SmartAVI
- Schalten Advantech
- Schalten Kraus & Naimer
- Schalten Chacon
- Schalten Juniper
- Schalten Fibaro
- Schalten Phoenix Contact
- Schalten Audac
- Schalten OSD Audio
- Schalten Wentronic
- Schalten SunBriteTV
- Schalten BZBGear
- Schalten Kemo
- Schalten ORNO
- Schalten Extron
- Schalten Atlona
- Schalten Equip
- Schalten Heitronic
- Schalten Hamlet
- Schalten STI
- Schalten Matrox
- Schalten Blustream
- Schalten Vivolink
- Schalten Mach Power
- Schalten Ernitec
- Schalten Cambium Networks
- Schalten ConnectPro
- Schalten Micro Connect
- Schalten Intelix
- Schalten ICasa
- Schalten Maclean Energy
- Schalten Cooking Performance Group
- Schalten Flic
- Schalten Liberty
- Schalten Noark
- Schalten 2USB
- Schalten KVM-TEC
- Schalten Setti+
- Schalten PureLink
Neueste Bedienungsanleitung für -Kategorien-
15 Oktober 2024
12 Oktober 2024
11 Oktober 2024
8 Oktober 2024
8 Oktober 2024
5 Oktober 2024
4 Oktober 2024
4 Oktober 2024
4 Oktober 2024
3 Oktober 2024