Clas Ohlson EF700ET - 32-8934 Bedienungsanleitung
Clas Ohlson
Schalten
EF700ET - 32-8934
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Clas Ohlson EF700ET - 32-8934 (20 Seiten) in der Kategorie Schalten. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/20
English
GREAT BRITAIN • customer service
tel: 08545 300 9799 customerservice@clasohlson.co.uk www.clasohlson.com/uke-mail: internet:
Ver. 20131212
a. AM (morning, before 1200)
b. PM (afternoon, after 1200)
c. Clock
d. Hour
e. Programme
f. Minutes
g. [ CD ] Countdown
h. Seconds
i. [ RND ] Random
j. No power supply to the wall socket
k. Programme is activated
l. [ S ] Daylight Saving Time
m. Power on
n. Mo–Su Days of the week
Setting theTime and Day
1. Press [ SET ] when “CLOCK” appears in thedisplay. The days
of theweek will start to flash and thesetup can begin.
2. Select theday using theup/down arrows [ ] and [ ▲ ▼ ].
3. Press [ SET ] when thecorrect day appears on thedisplay.
4. The hour digit will now start to flash, select thecorrect hour
using theup/down arrows [ ], press [ SET ] to save ▲ ] and [ ▼
thesetting when thecorrect hour is shown on thedisplay.
5. The minute digits will start to flash, select thecorrect minute
using theup/down arrows [ ] and [ ▲ ▼ ], press [ SET ] to
save thesetting when thecorrect time is shown on thedisplay.
Programming theTimer
1. Press [ P ] when “CLOCK” appears on thedisplay, 1
and “PROGRAM” are shown, thesymbols mean:
• The number represents theprogramme group (1–10).
• This symbol indicates when theprogramme comes on.
• This symbol indicates when theprogramme goes off.
• “PROGRAM” indicates that thedisplay is in programme
mode.
2. To select programme group and on/off time: Press [ ▲ ] to
advance in theprogramme groups and on/off time. Press
[ ] (first come on time) press [ ] (first go off time) and ▲ → ▲
so on for as many programmes as are required (up to 10).
1 → → → 1 , 2 → 2 ... 9 9 10 →
Press [ ] to go backwards in programme group and on/off time. ▼
Press [ press [ ] (10-on) and so on. ▼ ] (10-off) → ▼
10 → → → → → → 10 , 9 9 ......2 2 1 1
3. Press [ SET ] to confirm when thesettings appear on
the display.
4. The weekly display will flash, complete thesettings by
pressing [ ] to advance in thefollowing order: ▲
• Mo Tu We Th Fr Sa Su
The programmes are valid from Monday to Sunday.
• Mo Th Fr Sa Su→ Tu→ We→ → → →
The programmes are valid from Monday to Sunday.
• Mo Tu We Th Fr
The programmes are valid from Monday to Friday.
• Sa Su
The programmes are valid from Saturday to Sunday.
• Mo Tu We Th Fr Sa
The programmes are valid from Monday to Saturday.
• Mo We Fr
The programme is valid on Monday, Wednesday and
Friday.
• Tu Th Sa
The programme is valid on Tuesday, Thursday and
Saturday.
• Mo Tu Wed
The programmes are valid from Monday to Wednesday.
• Th Fr Sa
The programmes are valid from Thursday to Saturday.
Digital Time Switch
Art.no 32-8934 Model EF700ET
Features
• Programmable on/off switching of electrical devices, ideal
for lighting.
• Ideal for automation, saving energy and for home safety.
• Can be switched on/off manually like anormal on/off switch.
• Up to 70 on/off operations per week (10 programmes,
10 on, 10 off).
• Countdown or random function.
• Simple conversion to Summer Time.
Description
1. LCD Display - Displays time and programme setting.
2. [ SET ] - Starts and confirms programme.
3. [ RCL ] - Push and hold in to pause/continue programmes.
4. [ P ] - Select programme mode: Programme, Countdown,
Random on/off or Clock.
5. [ ON/OFF ] - On/Off
6. [ ] - Increase setting when programming. ▲
7. [ ] - Decrease setting when programming. ▼
8. [ R ] - (Reset) deletes all settings.
Symbols on theDisplay
a
b
c
d e f g h i
n
m
l
k
j
1
6
7
8
2
3
4
5
English
GREAT BRITAIN • customer service
tel: 08545 300 9799 customerservice@clasohlson.co.uk www.clasohlson.com/uke-mail: internet:
Ver. 20131212
Battery change
If thedigits in thedisplay disappear when thetimer is removed
from thepower point, thebatteries need to be changed. Remove
thedisplay according to point 3 below. The battery Connection
compartment is on theback of thedisplay. Change the2 batteries
to new ones of SR69 type.
Connection
1. Programme in thedesired ON/OFF times in thetimer as
explained above.
2. Remove thefuse from thepower point. Make sure there is
no power.
3. Disassemble thetime switch: Loosen thescrew (A) and
insert ascrewdriver at (B) and carefully bend.
4. Connect thecables to thetime switch according to fig. 3.
5. Mount thetime switch in thesocket moulding, and tighten. (Fig 4)
6. Mount theinner cover plate (fig. 5) with thescrews.
7. Fasten theexternal cover on inner cover plate.
8. Replace thefuse and test.
Specifications
Rated Voltage 230 V AC, 50 Hz
Max load 500 W or 3.15 A (resistive)
Batteries 2×1.5 V (SR69, V371)
5. Use [ ] to move backwards in reverse order, press [ SET ] ▼
to save thesettings when thecorrect day is shown.
6. The hour digit will now start to flash, select thecorrect hour
using theup/down arrows [ ] and [ ▲ ▼ ], press [ SET ] to
save thesetting when thecorrect hour is shown on thedisplay.
7. The minute digits will start to flash, select thecorrect minute
using theup/down arrows [ ] and [ ▲ ▼ ], press [ SET ] to
save thesetting when thecorrect time is shown on thedisplay.
8. Other programmes can be set or set programmes can be
changed by: repeating steps 2 to 7 described above.
Manual Function
NOTE: The symbol appears in thedisplay when thetime switch is
activated in either theon or off mode according to theprogramme:
• Press [ RCL ] and hold until thesymbol disappears, in order
to override thepre-programmed settings and control
the ON/OFF activation manually.
• Press [ RCL ] one more time in order to return to
the pre-programmed settings. The icon will reappear.
• The display automatically returns to displaying thetime
if no button is pushed within 15 seconds.
Countdown function
1. Press [ P ] when ”CLOCK” is shown on thedisplay until
the ”CD” symbol appears.
2. Press [ SET ] in order to begin programming. The hour display
begins to flash.
3. Select thecorrect hour using theup/down arrows [ ▲ ] and
[ ], press [ SET ] to save thesetting when thecorrect hour ▼
is shown on thedisplay.
4. The minute digits will start to flash, select thecorrect minute
using theup/down arrows [ ] and [ ], press [ SET ] to save ▲ ▼
thesettings. The countdown function can be set from 1 min.
up to 99 hrs. and 59 min.
5. The display must be in CD mode in order to start
the countdown function. Push [ ON/OFF ] in order to start.
”CD” flashes as areminder that acountdown is in progress
when thedisplay is in theCLOCK mode.
6. Press [ ON/OFF ] in order to stop acoundown (this only
works when ”CLOCK” shows on thedisplay.)
7. When thecountdown programme is active it is themain
programme. Even if there are other programme settings,
the countdown will continue for its set time and
subsequently turn off thepower.
Random function
1. Press [ P ] when ”CLOCK” is shown on thedisplay until
the ”RND” symbol appears.
2. Press [ ON/OFF ] in order to start/stop therandom function.
3. ”RND” flashes to when therandom function is active when
”CLOCK” is shown on thedisplay.
Example:
The set time is 06:00 (on) and 18:00 (off). When theran-
dom function is activated, thepower will be turned on approx.
16–24 minutes after 06:00 and is turned off approx. 24–42 minutes
before 18:00.
Other functions
Manual to/from operation
• Press once on thecover to turn on thepower. is shown in
thedisplay. If is also shown in thedisplay, this means that
thepre-programmed setting will dictate when thepower will
be shut off.
• Press once on thecover to turn on thepower. is shown
in thedisplay. If is also shown in thedisplay, this means
that thepre-programmed setting will dictate when thepower
will be shut off.
Daylight Savings Time
• Press theup/down arrows simultaneously [ ] and [ ▲ ▼ ] in
order to transition to Daylight Savings Time when ”CLOCK”
is shown on thedisplay. The time and theprogrammed
setting are now synchronised to Daylight Savings Time.
”S” now shows on thedisplay.
• Press theup/down arrows simultaneously [ ] and [ ▲ ▼ ]
in order to transition to standard time when ”CLOCK” is
shown on thedisplay. The time and theprogrammed
setting are now synchronised to standard time.
Reset
• Press [ R ] once in order to clear all programmed settings.
12/24 hour display
• When you have changed batteries or have pressed [ R ]
the 24 H will begin to flash, change to a12 hour clock
display by pressing [ ] or press [ ] to return to a24 hour ▲ ▼
display. Confirm by pressing [ SET ].
Fig. 1. Fig. 2.
Fig. 3. Fig. 4.
A
B
B
Fig. 5.
Produktspezifikationen
Marke: | Clas Ohlson |
Kategorie: | Schalten |
Modell: | EF700ET - 32-8934 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Clas Ohlson EF700ET - 32-8934 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Schalten Clas Ohlson
19 Juli 2024
Bedienungsanleitung Schalten
- Schalten Asus
- Schalten Belkin
- Schalten Hama
- Schalten HP
- Schalten LogiLink
- Schalten Manhattan
- Schalten Nedis
- Schalten Philips
- Schalten SilverCrest
- Schalten Panasonic
- Schalten Brennenstuhl
- Schalten Cotech
- Schalten Profile
- Schalten ZyXEL
- Schalten Bosch
- Schalten Yamaha
- Schalten Powerfix
- Schalten CSL
- Schalten Eminent
- Schalten Linksys
- Schalten Netgear
- Schalten König
- Schalten PCE
- Schalten Renkforce
- Schalten Trotec
- Schalten Schneider
- Schalten Rex
- Schalten Kaiser
- Schalten Vivanco
- Schalten Abus
- Schalten Elro
- Schalten Smartwares
- Schalten Tesla
- Schalten Perel
- Schalten Nexa
- Schalten Tork
- Schalten GEV
- Schalten Goobay
- Schalten Lindy
- Schalten Tripp Lite
- Schalten Ansmann
- Schalten Mercusys
- Schalten Marmitek
- Schalten Honeywell
- Schalten TRENDnet
- Schalten TP-Link
- Schalten Kathrein
- Schalten Flamingo
- Schalten Alcatel
- Schalten Tiptel
- Schalten Black Box
- Schalten Alpine
- Schalten Techly
- Schalten Ebode
- Schalten Theben
- Schalten Vacmaster
- Schalten GAO
- Schalten Hager
- Schalten Behringer
- Schalten Omnitronic
- Schalten Monoprice
- Schalten Ecler
- Schalten Monacor
- Schalten Huawei
- Schalten JUNG
- Schalten Victron Energy
- Schalten Ei Electronics
- Schalten Edimax
- Schalten Totolink
- Schalten D-Link
- Schalten Sylvania
- Schalten Audiovox
- Schalten B-Tech
- Schalten QNAP
- Schalten SPC
- Schalten Speaka
- Schalten Digitus
- Schalten Sygonix
- Schalten DataVideo
- Schalten Lancom
- Schalten LevelOne
- Schalten Merten
- Schalten APC
- Schalten Eberle
- Schalten Cisco
- Schalten Delta Dore
- Schalten Grässlin
- Schalten Tenda
- Schalten CyberPower
- Schalten Boss
- Schalten IFM
- Schalten Intertechno
- Schalten Elation
- Schalten Ubiquiti Networks
- Schalten Kramer
- Schalten Aeon Labs
- Schalten Intellinet
- Schalten Eaton
- Schalten AV:link
- Schalten Hikvision
- Schalten Vemer
- Schalten PreSonus
- Schalten Planet
- Schalten EnGenius
- Schalten Finder
- Schalten Mikrotik
- Schalten Shimano
- Schalten Homematic IP
- Schalten Berker
- Schalten Dormakaba
- Schalten Emerson
- Schalten Generac
- Schalten Intermatic
- Schalten KlikaanKlikuit
- Schalten Mercury
- Schalten Paladin
- Schalten Provision ISR
- Schalten Robbe
- Schalten SEC24
- Schalten Steren
- Schalten Suevia
- Schalten AMX
- Schalten Triax
- Schalten WHALE
- Schalten Vimar
- Schalten Cudy
- Schalten Siig
- Schalten Electro Harmonix
- Schalten RGBlink
- Schalten Iogear
- Schalten StarTech.com
- Schalten Smart-AVI
- Schalten Dahua Technology
- Schalten PAC
- Schalten Gefen
- Schalten Avocent
- Schalten Legrand
- Schalten Atlantis Land
- Schalten CYP
- Schalten H-Tronic
- Schalten ATen
- Schalten Axing
- Schalten KanexPro
- Schalten SmartAVI
- Schalten Advantech
- Schalten Kraus & Naimer
- Schalten Chacon
- Schalten Juniper
- Schalten Fibaro
- Schalten Phoenix Contact
- Schalten Audac
- Schalten OSD Audio
- Schalten Wentronic
- Schalten SunBriteTV
- Schalten BZBGear
- Schalten Crestron
- Schalten Kemo
- Schalten ORNO
- Schalten Extron
- Schalten Atlona
- Schalten Equip
- Schalten Heitronic
- Schalten Hamlet
- Schalten STI
- Schalten Matrox
- Schalten Blustream
- Schalten Vivolink
- Schalten Mach Power
- Schalten Ernitec
- Schalten Cambium Networks
- Schalten ConnectPro
- Schalten Micro Connect
- Schalten Intelix
- Schalten ICasa
- Schalten Maclean Energy
- Schalten Cooking Performance Group
- Schalten Flic
- Schalten Liberty
- Schalten Noark
- Schalten 2USB
- Schalten KVM-TEC
- Schalten Setti+
- Schalten PureLink
Neueste Bedienungsanleitung für -Kategorien-
15 Oktober 2024
12 Oktober 2024
11 Oktober 2024
8 Oktober 2024
8 Oktober 2024
5 Oktober 2024
4 Oktober 2024
4 Oktober 2024
4 Oktober 2024
3 Oktober 2024