Chef CS902S Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Chef CS902S (4 Seiten) in der Kategorie Afzuigkap. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/4
AR500FS
Rear Exhaust
to atmosphere
Side Exhaust
to atmosphere
Recirculating
Installation
Top Exhaust
to atmosphere
AR125RC
AR125F
AR125FD
Roof cowl
Flue
1200mm length
Alternative flue connection
1 metre flexible duct with joiners
Flashing
Not Supplied
90º bend
AR125B
AR500RK
AR125WV
Wall vent
(includes 400mm of flue)
600-900 Canopy Installation and Operation Manual
The instructions in this manual are for cooker hood models: CS601S,CS602S, CS902S, CS901S, WRF600, WRF600CS, WRF900CS,
WRG630CW,WRG630CS,WRG930CW,WRG930CS,RCD690S,RCD990S
Safety Warnings
Electrical Connection
Accessories
Cleaning
Part Numbers: Description:
These cooker hoods are domestic appliances which have been manufactured and tested to comply with Australian and New Zealand
Standard AS/NZS 3350.2.31.
These appliance are intended to be used in household and similar applications such as: Staff kitchen areas in shops, ofî‚¿ces and other
working environments; Farm Houses; By clients in hotels, motels and other residential type environments; Bed and breakfast type
environments.
This appliance is not intended for used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Ensure the cooker hood is switched off before carrying out maintenance, to avoid any possibility of electric shock.
Grease î‚¿lters must be removed every four weeks (maximum) for cleaning to reduce the risk of î‚¿re.
Do not amb’e under the cooker hood.
This cooker hood is not recommended for barbeques.
The exhaust air from the cooker hood must not be discharged into any heating ue, which may carry combustion products from other sources.
Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for the purpose.
There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning gas or other fuels.
Always cover lit gas burners with pots or pans when the cooker hood is in use.
Always switch off gas burners before you remove pots or pans.
CAUTION: Accessible parts may become hot when used with cooking appliance.
Regulations concerning the discharge of air have to be fulî‚¿lled.
Check that the mains voltage matches with the voltage on the data plate inside the cooker hood.
Check that the installation complies with standards of local gas and electricity authorities.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualied person in order to avoid a hazard.
Use 125mm round exhaust ducting for best performance.
When using exible duct always install duct with the wire helix pulled taut to minimise pressure loss.
Try to keep exhaust duct short and straight.
Keep bends in the exhaust duct to a minimum.
Do not reduce the size or restrict exhaust duct.
Wipe the cooker hood body and ue with a sponge or soft cloth soaked in warm soapy water. Do not use oven cleaners or other abrasive materials.
AR125RC
AR125B
AR125F
AR125FD
AR125VW
AR500FS
AR500RK
AR500CF
Roof Cowl
90º Bend
Flue 1200mm Long
Flexible Duct - 1 Metre Long When Expanded
Wall Vent Kit
Extra Length Flue Cover 1100mm Length Brushed Stainless Steel
Recirculating Kit
Replacement Carbon Filters
DUCTING ACCESSORIES
INSTALLATION OPTIONS
Page 1
203203
(600 model)
(600 model)
C
L
Hood base
Top of hob
MINIMUM:
600 electric
650 gas
MAXIMUM:
800 mm
245
75 75
65 65
38 303303
600 models as per this diagram with these dimensions the only variables
490
B
Page 2
Warning: Failure to install the screws or xing device in accordance with these instructions may result in electrical hazards.
COMPONENTS LIST
COMPONENTS NOT INCLUDED
Diagram B:
INSTALLING THE COOKER HOOD
NOTE:
NOTE:
1 body assembly with grease î‚¿lters
(900-3 grease î‚¿lters / 600-2 grease î‚¿lters)
1 telescopic ue cover set
2 cover ue mounting brackets
1 instruction book
1 plastic bag containing screws for î‚¿xing
telescopic ue covers
1 plastic duct transition: oblong to round
Fixings required to attach cover ue
mounting brackets to wall
Fixings required to attach the cooker hood
to wall
Recommended working heights.
Cover ue mounting bracket locations.
Telescopic cover ue xing points.
Before installing the cooker hood, peel off any
protective plastic covering.
Remove polystyrene packaging from inside
behind fan motor.
(Diagrams C )
Some installations may require telescopic
ue cover cut to length. Cut with tin snips or
a î‚¿ne-tooth hack saw blade, taking care not
to distort or dent ue cover.
The maximum space between the wall and
screw top is 5mm.
If the instructions of the hob
specify a greater distance than
the minimum, then that shall
be the minimum height for the
installation
DIMENSIONS ARE IN MILLIMETRES
A
222
165
230
500
600/900
20
max)1240(
540
470(max)
C
E
FF
G
D
RECOMMENDED INSTALLATION SEQUENCE COOKER HOOD OPERATION
Diagram D
Slide switch controls:
Replacing lamps:
Press button switch controls
Maintenance:
Diagram E
NOTE:
Install cooker hood body.
Determine working height, mark
wall to suit.
Install cover ue mounting
brackets.
Light switch:
Extractor fan switch:
Slide position I:
Slide position 2:
Slide position 3:
Ensure the appliance is switched off before carrying out
maintenance, to avoid any possibility of electric shock. Remove
grease î‚¿lter to replace lamp. Replace with 40W (maximum) E14
candle lamp.
Light switch: Depress
light button to turn light
ON. Press light button to
turn light .OFF
Clean grease î‚¿lters
every three to four weeks
maximum.
Greasy î‚¿lters are a î‚¿re
risk.
Remove the grease î‚¿lters,
soak and agitate in hot
soapy water.
Rinse, drain and shake
well before replacing
î‚¿lters.
Do not use oven cleaners
or other caustic materials.
Extractor fan switch
interlocked switching:
Select a fan speed,
depress button to turn
fan . Press button ( ) ON O
to turn fan .OFF
Fix duct transition to cooker hood
body.
Install internal exhaust duct to suit
installation type.
Best results are obtained by using a low fan speed for normal
conditions and a high fan speed when odours are more
concentrated. Turn the hood on a few minutes before you start
cooking. It should by left on after cooking for about 15 minutes or
until all odours have disappeared.
This product is î‚¿tted with a safety cutout device. If the cooker hood
is installed to close to the cooktop, ambe cooking, operating the
cooktop without cooking utensils and blocked î‚¿lters may activate
the safety cutout device. if the hood stops during operation, correct
the faults and allow time for the safety cutout device to reset, the
cooker hood will then function correctly.
Page 3
Diagram(s) F
Diagram G
Install bottom section of
telescopic ue cover.
Install top section of
telescopic ue cover.
This switch is used to turn the
light î‚¿tted in the hood on and off.
Used to select fan speeds.
Fan speed Low
Fan speed Medium
Fan speed High
- - - - - - - - - - - - - -
- - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
IMPORTANT: The Edison Screw lamps may have come loose
during transportation. Ensure that lamps are tightened î‚¿rmly
into the socket before power is applied.
3
2
0
0
Produktspezifikationen
Marke: | Chef |
Kategorie: | Afzuigkap |
Modell: | CS902S |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Chef CS902S benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Afzuigkap Chef
4 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
4 September 2024
21 August 2024
21 August 2024
Bedienungsanleitung Afzuigkap
- Afzuigkap Samsung
- Afzuigkap Infiniton
- Afzuigkap Adelberg
- Afzuigkap Hanseatic
- Afzuigkap Panasonic
- Afzuigkap LG
- Afzuigkap Bestron
- Afzuigkap Guzzanti
- Afzuigkap MX Onda
- Afzuigkap Bosch
- Afzuigkap AEG
- Afzuigkap Asko
- Afzuigkap Siemens
- Afzuigkap ATAG
- Afzuigkap Bauknecht
- Afzuigkap Concept
- Afzuigkap Electrolux
- Afzuigkap Fagor
- Afzuigkap Gaggenau
- Afzuigkap Gorenje
- Afzuigkap Klarstein
- Afzuigkap Küppersbusch
- Afzuigkap Miele
- Afzuigkap Teka
- Afzuigkap Whirlpool
- Afzuigkap Bomann
- Afzuigkap Russell Hobbs
- Afzuigkap Vox
- Afzuigkap IKEA
- Afzuigkap ECG
- Afzuigkap Amica
- Afzuigkap BEKO
- Afzuigkap Blaupunkt
- Afzuigkap Boretti
- Afzuigkap Grundig
- Afzuigkap Heinner
- Afzuigkap Hotpoint
- Afzuigkap Inventum
- Afzuigkap KitchenAid
- Afzuigkap Schneider
- Afzuigkap Sharp
- Afzuigkap Smeg
- Afzuigkap AEG-Electrolux
- Afzuigkap Ardo
- Afzuigkap Ariston
- Afzuigkap Aspes
- Afzuigkap Balay
- Afzuigkap Blomberg
- Afzuigkap Scandomestic
- Afzuigkap Brandt
- Afzuigkap Candy
- Afzuigkap Constructa
- Afzuigkap Corberó
- Afzuigkap Edesa
- Afzuigkap ELIN
- Afzuigkap Eudora
- Afzuigkap Eurotech
- Afzuigkap Exquisit
- Afzuigkap GE
- Afzuigkap Haier
- Afzuigkap High One
- Afzuigkap Hisense
- Afzuigkap Hoover
- Afzuigkap Hotpoint-Ariston
- Afzuigkap Ignis
- Afzuigkap Bartscher
- Afzuigkap Indesit
- Afzuigkap Juno
- Afzuigkap Baumatic
- Afzuigkap Kelvinator
- Afzuigkap Bertazzoni
- Afzuigkap Maytag
- Afzuigkap Midea
- Afzuigkap Caple
- Afzuigkap Neff
- Afzuigkap Nordmende
- Afzuigkap PKM
- Afzuigkap Privileg
- Afzuigkap Progress
- Afzuigkap Rex
- Afzuigkap Rommer
- Afzuigkap ETNA
- Afzuigkap Scholtès
- Afzuigkap Frigidaire
- Afzuigkap SIBIR
- Afzuigkap Svan
- Afzuigkap Thor
- Afzuigkap V-ZUG
- Afzuigkap Junker
- Afzuigkap Zanker
- Afzuigkap Zanussi
- Afzuigkap KKT Kolbe
- Afzuigkap M-System
- Afzuigkap Monogram
- Afzuigkap Oranier
- Afzuigkap Pelgrim
- Afzuigkap Philco
- Afzuigkap Respekta
- Afzuigkap Rosières
- Afzuigkap Thermador
- Afzuigkap Viva
- Afzuigkap Arçelik
- Afzuigkap Continental Edison
- Afzuigkap Kernau
- Afzuigkap Tesla
- Afzuigkap Imperial
- Afzuigkap Elica
- Afzuigkap DeLonghi
- Afzuigkap Eico
- Afzuigkap Franke
- Afzuigkap Wolkenstein
- Afzuigkap Frilec
- Afzuigkap Honeywell
- Afzuigkap Foster
- Afzuigkap Weller
- Afzuigkap Silverline
- Afzuigkap Novy
- Afzuigkap Airforce
- Afzuigkap Airlux
- Afzuigkap Broan
- Afzuigkap Cata
- Afzuigkap Cylinda
- Afzuigkap De Dietrich
- Afzuigkap Dominox
- Afzuigkap Elba
- Afzuigkap Falcon
- Afzuigkap Falmec
- Afzuigkap Faure
- Afzuigkap Hansa
- Afzuigkap Leisure
- Afzuigkap MPM
- Afzuigkap Nodor
- Afzuigkap Roblin
- Afzuigkap Sauter
- Afzuigkap Stoves
- Afzuigkap Thermex
- Afzuigkap UPO
- Afzuigkap Bielmeier
- Afzuigkap Logik
- Afzuigkap Dacor
- Afzuigkap Orima
- Afzuigkap Proline
- Afzuigkap Dimplex
- Afzuigkap Faber
- Afzuigkap Mora
- Afzuigkap Toolcraft
- Afzuigkap Westinghouse
- Afzuigkap Wolf
- Afzuigkap Amana
- Afzuigkap Arthur Martin-Electrolux
- Afzuigkap Euromaid
- Afzuigkap Gram
- Afzuigkap Tesy
- Afzuigkap Vivax
- Afzuigkap Omega
- Afzuigkap Profilo
- Afzuigkap Sauber
- Afzuigkap Zelmer
- Afzuigkap Kleenmaid
- Afzuigkap Lamona
- Afzuigkap Limit
- Afzuigkap Meireles
- Afzuigkap Viking
- Afzuigkap Acec
- Afzuigkap Ariston Thermo
- Afzuigkap Gutmann
- Afzuigkap Signature
- Afzuigkap Bellini
- Afzuigkap Best
- Afzuigkap Soler & Palau
- Afzuigkap AYA
- Afzuigkap Fisher & Paykel
- Afzuigkap Esatto
- Afzuigkap Orbegozo
- Afzuigkap Napoleon
- Afzuigkap Ilve
- Afzuigkap Furrion
- Afzuigkap Unox
- Afzuigkap CDA
- Afzuigkap Saturn
- Afzuigkap Berg
- Afzuigkap Defy
- Afzuigkap Itho
- Afzuigkap Jocel
- Afzuigkap Kenmore
- Afzuigkap La Germania
- Afzuigkap Marynen
- Afzuigkap Mepamsa
- Afzuigkap Piccante
- Afzuigkap Rangemaster
- Afzuigkap Scancool
- Afzuigkap Sirius
- Afzuigkap Steelmatic
- Afzuigkap Technika
- Afzuigkap Tecnolux
- Afzuigkap BLANCO
- Afzuigkap Turbo Air
- Afzuigkap Zephyr
- Afzuigkap Whispair
- Afzuigkap Kunft
- Afzuigkap Kucht
- Afzuigkap Schweigen
- Afzuigkap Becken
- Afzuigkap Wells
- Afzuigkap JennAir
- Afzuigkap BlueStar
- Afzuigkap Fulgor Milano
- Afzuigkap Air King
- Afzuigkap Flama
- Afzuigkap Halifax
- Afzuigkap ZLine
- Afzuigkap K&H
- Afzuigkap Arctic Cooling
- Afzuigkap Barazza
- Afzuigkap Qasair
- Afzuigkap Artusi
- Afzuigkap Glem Gas
- Afzuigkap Sôlt
- Afzuigkap Sam Cook
- Afzuigkap LERAN
- Afzuigkap Belling
- Afzuigkap Cookology
- Afzuigkap Summit
- Afzuigkap Linarie
- Afzuigkap Everdure
- Afzuigkap Euro Appliances
- Afzuigkap NuTone
- Afzuigkap Robinhood
- Afzuigkap XO
- Afzuigkap Venmar
- Afzuigkap Café
- Afzuigkap Porter & Charles
- Afzuigkap Jenn-Air
- Afzuigkap New World
- Afzuigkap Belion
- Afzuigkap Tisira
- Afzuigkap Ciarra
- Afzuigkap CENDO
- Afzuigkap Twin Eagles
- Afzuigkap Airone
- Afzuigkap Kluge
- Afzuigkap Trade-Wind
- Afzuigkap Mayer
- Afzuigkap Vent-A-Hood
- Afzuigkap HomeCraft
- Afzuigkap CEEM
Neueste Bedienungsanleitung für -Kategorien-
17 September 2024
17 September 2024
17 September 2024
17 September 2024
17 September 2024
17 September 2024
17 September 2024
17 September 2024
17 September 2024
17 September 2024