Chauvet PowerStream 4 IP Bedienungsanleitung

Chauvet Nicht kategorisiert PowerStream 4 IP

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Chauvet PowerStream 4 IP (12 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
Quick Start Guide
English EN
Español ES
Français FR
Deutsch DE
Nederlands NL
1
EN
QUICK REFERENCE GUIDE
PowerStream 4 IP QRG Rev. 1
About This Guide
The PowerStream 4 IP Quick Reference Guide (QRG) has basic product information such as mounting and connection.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
• DO NOT open this product. It contains no user-serviceable parts.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
• CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
• CAUTION: This product’s housing may be hot when lights are operating.
• Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
• DO NOT leave any flammable material within 1.97 in (5 cm) of this product while operating or connected to power.
• USE a safety cable when mounting this product overhead.
• DO NOT submerge this product (IP65). Regular outdoor operation is fine.
• DO NOT operate this product if the housing or cables appear damaged.
• ONLY connect this product to a grounded and protected circuit.
• In the event of a serious operating problem, stop using immediately.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or
return a product. Refer to Contact Us at the end of this QRG for contact information.
What is Included
Product Overview
• PowerStream 4 IP
• Quick Reference Guide
Power indicator Power input Power outputs
EN
2
PowerStream 4 IP QRG Rev. 1
QUICK REFERENCE GUIDE
AC Power
This product can work with an input voltage range of 100–240 VAC, 50/60 Hz.
Setup
1. Plug a power cord in to the power input.
2. Plug any additional products in to the power outputs.
3. Additional PowerStream 4 IP products can be daisy chained by plugging in to any empty power output.
Mounting
Before mounting this product, read the Safety Notes.
Mounting Diagram
Technical Specifications
Dimensions and Weight
Note: Dimensions in inches are rounded.
Power
Ordering
• Do not exceed 16 amps throughout the entire power run.
• The maximum load for the PowerStream 4 IP is 16 amps. Do not exceed this rating.
• The maximum current for any power output on the PowerStream 4 IP is 16 amps. Do not exceed this
rating.
Length Width Height Weight
10.81 in (274.5 mm) 3 in (76.2 mm) 2.68 in (68 mm) 3 lb (1.36 kg)
Input Voltage Voltage Selection Maximum Pass-Through Current
100–240 VAC, 50/60 Hz Auto-Ranging 16 A
Power I/O U.S./Worldwide UK/Europe
Power Input Connectors TRUE1 style Compatible Seetronic
PowerKon IP65
TRUE1 style Compatible Seetronic
PowerKon IP65
Power Output Connector TRUE1 style Compatible Seetronic
PowerKon IP65 (x4)
TRUE1 style Compatible Seetronic
PowerKon IP65 (x4)
Product Name Item Name Item Code UPC Number
PowerStream 4 IP POWERSTREAM4 IP 09081276 781462216245
!
Safety cable
Mounting clamp
Carry handle


Produktspezifikationen

Marke: Chauvet
Kategorie: Nicht kategorisiert
Modell: PowerStream 4 IP

Brauchst du Hilfe?

Wenn Sie Hilfe mit Chauvet PowerStream 4 IP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Chauvet

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-