TF10 - Single lever filter tap
5 Year warranty:
In the unlikely event that you should experience any defect in the materials or workmanship of your new CDA mixer within FIVE years of
purchase, the purchaser’s sole remedy shall be the replacement (at the manufacturer’s discretion) of all or any part of the product that is
defective. All working parts and valves are guaranteed for a period of TWO years from purchase. Decorative surface finishes and O-rings
are guaranteed for ONE year from the date of purchase provided that our advice concerning care has been observed. This is provided that
the mixer has been used for normal domestic purposes in the UK and that the care, installation and maintenance instructions have been
observed. The warranty extends to the original purchaser only. You should retain a copy of your dated invoice as proof of purchase to
validate any claims under this guarantee.
Care Instructions for your Kitchen Sink Mixer:
To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water and
a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Any other cleaning action will
invalidate your warranty. If the tap has a diffuser it should be cleaned periodically.
Abrasive cleaners, scouring cleaners and acidic cleaners must not be used under any circumstances. Avoid contact with all solvents
(including chlorinated solvents, ketones or acetones as these may result in surface deterioration or etching). Also avoid contact with any
harsh household chemicals such as oven cleaners, drain cleaners, rust removers, paint strippers and toilet bowl cleaners, bar keepers friend
or Brasso.
Important Technical Data:
Minimum hot / cold operating pressure / 1.0 bar Maximum hot water temperature 70°C* 0.5
Maximum operating pressure 5.5 bar* Recommended hot water temperature 46°C
*If these temperatures or pressures are exceeded, even for short periods, damage can result.
CDA taps are either WRAS approved or manufactured in accordance with recognised European standards. Please ensure that your
Kitchen mixer is fitted in accordance with Local Water Byelaws.
These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept
responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally loosen any
screwed assemblies.
Installation Preparation:
Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any remaining
solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or damage to the workings of
the mixertap.
We strongly recommend installing particle filter strainers and isolation valves to both the hot and cold feed pipes in an accessible position.
This will help to prevent premature failure of the valves and ease any future maintenance.
All parts should be removed from their packaging and inspected for completeness any transport damage prior to installation.
Shut off your water heating system and ensure that your mains stopcock is closed. Open the lowest hot and cold taps in the house and
allow the water to run until the cold-water storage tank and pipes are fully empty. Please note, the hot water storage cylinder (if applicable)
will always remain full.
This mixertap requires a 35mm tap hole, if replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool the ∅
tap hole area should be free from dirt and sealant.
This tap can be used in conjunction with a water softening system and will remove the need for a separate drinking water tap. In this
instance the isolator valve (U) must cut into the unsoftened cold mains supply.
Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required, if this is the case do this now.
Stage 1 – install the tap:
1. Screw the fixing stud (F) into the base of the tap (A).
2. Place the upper sink seal (B) on the base of the tap (A).
3. Screw the hot (H), cold (I) & filtered (J) water tail pipes into the base of the tap (A). Note: the drawing key identifies water inlets.
4. Place the tap (A) and seal (B) centrally to the tap hole, passing the fixing stud (F) and tail pipes (H, I & J) through the sink.
5. Pass the rubber horseshoe (D) then the metal horseshoe (E) over the fixing stud (F). Note: if the tap is to be fitted to a stainless
steel sink then the white triangular plate (C) can be fitted where shown to improve the stability of the tap.
6. Using a spanner tighten fixing nut (G) onto the fixing stud (F) securing the tap (A).
7. Connect the flexible ½” hot pipe (H) to the hot water supply using the appropriate sized compression fittings.
8. Place the ¼” rubber seal (J1) into flexi pipe (J), now tighten the ¼” pushfit (K) into the end of the flexible filtered water pipe (J). Note
PTFE tape can be used on the thread of pushfit (K) to ensure a water tight joint.
9. Using compression nuts (S) and olives (T) connect the 3-way tee (U) as shown to the 15mm cold water supply feed.
10. Attach a short stub of 15mm pipe (3) to the 3-way tee (U) as shown using compression nuts (S) and olives (T).
11. Connect the flexible ½” cold pipe (I) to the 15mm pipe stub (3) using the appropriate sized compression fittings (1 & 2).
Stage 2 – install the filter:
1. Locate a convenient position to install the filter (N), remembering that it must be accessible when it is to be changed and functions
best when mounted vertically.
2. Screw the filter bracket (P) to the cupboard wall using screws (O), if attaching the bracket to an interior wall use rawl plugs also.
3. Remove the dust caps from the ends of the filter (N) and write the installation date onto its label. Firmly push the pushfit connectors
(M & Q) onto each end of the filter.
4. Clip the filter (N) into its bracket (P) noting the direction of flow through the filter (N) towards the tap (A).
5. Cut the blue flexible pipe (L) so it is slightly longer than the required lengths to and from the filter unit (N). When cutting the pipe
use a sharp Stanley knife, ensuring that the pipe is cut cleanly and square at all ends.
6. Firmly push the blue pipe (L) apx. 12mm into the pushfit connector (K) and push fit connector (M).
7. Screw the large pushfit adaptor (R) onto the 3 way tee (U)
8. Firmly push the blue pipe (L) apx. 12mm into the pushfit connector (Q) and push fit adaptor (R).
After installation:
Once you have visually checked the new fittings and connections, ensure that all taps are closed except the new mixer tap, which should be
left open. Turn on the water supply at the mains stop cock. As the system starts to refill, check carefully for leaks. Once you are fully
satisfied that there are no leaks, turn on the water heating. Clean the tap to remove any marks created during installation as instructed then
replace the bag that has been provided to protect the tap until it is ready for use.
Stage 3 – setting the tap up:
1. The filtered drinking water system performs at a maximum of 2-3 L /
min. Turn the tap fully on to filtered water, now the turn the lever on
the 3-way valve (U) to adjust the flow of filtered water to the correct
level. Note when the filter is new it will take a moment to pull any air
though the system, you may notice some carbon discoloration in the
water at this point, this is normal and will pass with flushing.
Using the tap:
For best results when using the filtered water always run the tap for a few moments. Running
the tap will help to flush the system through and make the water cooler for drinking, if the tap
has not been used for several hours then flush the tap for longer. When comparing the taste
of filtered and unfiltered water always taste the filtered water first.
The dual stage filter is designed to improve the taste, clarity and odour of drinking water, the
filter also the help to reduce the level of chemical impurities and lime scale build up on
kettles and cookware in low-moderate scale regions.
Each filter cartridge has a maximum 6-month life. For replacement filters call 01949 862012.
To select filtered water turn the lever off, then fully right past the ‘click’ to select filtered water,
tilt the lever to control the filtered water flow.
To select hot, cold or mixed water turn the lever off, now turn to the left past the ‘click’ to
select non filtered water, tilt the lever to control the hot, cold or mixed water flow.
The tap will not switch from filtered to non filtered water without the tap being turned off first.
Key Description Qty.
A Tap body 1
B Upper sink / worktop seal 1
C White triangular stabilizing plate
(for use with stainless sinks only) 1
D Rubber horseshoe 1
E Metal horseshoe 1
F Fixing stud 1
G Fixing nut 1
H Hot water ½” flexi pipe with non return
valve insert 1
I Cold water ½” flexi pipe with non
return insert 1
J Filter water ¼” flexi pipe 1
J1 ¼” rubber seal 1
K ¼” Pushfit connector 1
L Blue flexible pipe 1m
M Pushfit connector 1
N Filter cartridge 1
O Self tapping screws 2
P Filter cartridge bracket 1
Q Pushfit connector 1
R Valve pushfit adaptor 1
S Compression nuts 2
T Compression olives 2
U Isolator valve 1
1 15mm Compression olive
2 15mm Compression nut
3 Stub of 15mm pipe
Not
supplied
Produktspezifikationen
Marke: | CDA |
Kategorie: | Wasserhahn |
Modell: | TF10CH |
Brauchst du Hilfe?
Wenn Sie Hilfe mit CDA TF10CH benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Wasserhahn CDA
25 April 2024
14 März 2024
22 Januar 2024
23 November 2023
12 November 2023
6 November 2023
4 September 2023
19 August 2023
Bedienungsanleitung Wasserhahn
- Wasserhahn Ernesto
- Wasserhahn Teka
- Wasserhahn IKEA
- Wasserhahn Inventum
- Wasserhahn KitchenAid
- Wasserhahn Smeg
- Wasserhahn Caple
- Wasserhahn ETNA
- Wasserhahn Easy Home
- Wasserhahn Franke
- Wasserhahn Nodor
- Wasserhahn Stiebel Eltron
- Wasserhahn Miomare
- Wasserhahn Camargue
- Wasserhahn Grohe
- Wasserhahn Delta
- Wasserhahn Hansgrohe
- Wasserhahn Brita
- Wasserhahn Schütte
- Wasserhahn Damixa
- Wasserhahn HOTTO
- Wasserhahn Mizzo
- Wasserhahn Oras
- Wasserhahn Berg
- Wasserhahn Quooker
- Wasserhahn Mueller
- Wasserhahn Livarno Lux
- Wasserhahn Elkay
- Wasserhahn Deante
- Wasserhahn Everpure
- Wasserhahn ZLine
- Wasserhahn Sani-Lav
- Wasserhahn Fala
- Wasserhahn The Galley
- Wasserhahn Empire
- Wasserhahn Aloni
- Wasserhahn Danze
- Wasserhahn Omnires
- Wasserhahn Rohl
- Wasserhahn CurAqua
- Wasserhahn Sussex
- Wasserhahn Fantini
- Wasserhahn Oliveri
- Wasserhahn Axor
- Wasserhahn Rogerseller
Neueste Bedienungsanleitung für -Kategorien-
21 Juni 2024
20 Juni 2024
20 Juni 2024
20 Juni 2024
19 Juni 2024
13 Juni 2024
13 Juni 2024
7 Juni 2024
1 Juni 2024
1 Juni 2024