Braemar Ecostar WF2000 Bedienungsanleitung

Braemar Heizung Ecostar WF2000

Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Braemar Ecostar WF2000 (2 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war fĂĽr 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
Warranty Service
Australia 1-300-650-644
seeleyinternational.com
612195M AU 110
seeleyinternational.com.au
(English) (WF30/40)
OWNER’S MANUAL
Wall Furnace - WF30/40
Name of Technician and company
(Print)
Signature of Technician
Date of attendance
Year 2 4 86 10
Maintenance Schedule
Cabinet and components
Cabinet
Heat exchanger
Electrical connections
Combustion air inlet louvres
Electrical
Electrical wiring
Room fan motor / impellor
Thermocouple voltage
Overtemp switch
Operation
Start up and run sequence
Control operation
Complete ignition
Gas inlet pressure
Gas test point pressure High
General installation
Rear register
Flue system, cowl
Gas, burners, ignition
Main burner and injector
Pilot gas rate
Pilot ignition / ignition electrode
Gas test point pressure Low
Thermostat operation
Draught diverter (NOTE 1)
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa
Action taken key:
= Inspected and working correctly no action required
A = Adjustment of part
C = Cleaning of part
R = Replaced part
Pilot burner and injector
It is a condition of your warranty cover that the items in the Schedule below are checked (and action taken as required)
every two (2) years after the date of installation by a qualified, licenced technician, and that the Schedule is properly
filled out (ie names, signature, date, and action taken). Even after the warranty period expires, please continue to have
the product maintained every two years as per the items in the Schedule. This will help to prolong the life of the product
and keep it running efficiently.
It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to change without notice.
Please consult with your dealer to confirm the specifications of the model selected.
To owner/user: please note that as explained in your Warranty Card, installation is not covered by the warranty (for example, electrical and gas
connections to the Wall Furnace). However, we still require that you have these things checked, because they can affect the performance (and/or
safety) of the heater. This is why we have included them in the Maintenance Schedule. Further, routine maintenance may be required more
frequently in non-domestic applications or when operating in adverse environmental situations. It is your obligation to ensure that you comply with
these requirements.
Electrical and gas connections
NOTE 1:
Check operation of flue and draft diverter in accordance with detailed instructions included in AS/NZS 56001.
SEELEY INTERNATIONAL – OWNER’S MANUAL 2
Introduction
For satisfactory performance of your
Braemar gas wall furnace, please read
these instructions carefully. The
operation of the heater is controlled by
the gas control knob and fan switch
located behind the access door on the
front cover.
Fan Operation
The fan will start automatically in both
AUTO and BOOST positions when the
unit is warm enough after the burner is
turned on, and stop automatically when
the unit has cooled sufficiently after the
burner turns off. With AUTO selected
the unit will automatically select
between "low" and "normal" (and
“boost” on 40MJ models) fan speeds
based on the heated air temperature -
no further user adjustment is necessary.
When BOOST is selected the fan will
run only on its boost speed. It is
recommended that the manual fan
switch be set to AUTO for normal
operation, or BOOST for rapid heat-up.
Gas Control
To light the heater:
- Turn the gas control knob anti-
clockwise from the “0” position to the
position.
- Depress knob fully and hold down.
- Press the igniter button located next to
the gas control knob 3-4 times.
- Observe the pilot meter to indicate
operation of the pilot.
- Wait 20 seconds then release the gas
control knob and check the pilot meter
stays on.
- Repeat the process if required.
OPERATING INSTRUCTIONS
1 WF30/40
Gas control knob
Igniter button
Pilot meter
Fan
Auto / Boost
switch
IMPORTANT MAINTENANCE (AND WARRANTY) INFORMATION
As with any product that has moving parts or is subject to wear and tear, it is VERY
IMPORTANT that you maintain your wall furnace and have it regularly serviced. It is a
condition of warranty cover for your wall furnace that you comply with all of the maintenance
and service requirements set out in this Owner’s Manual. Compliance with these
requirements will prolong the life of your wall furnace. Further, it is also a condition of
warranty cover that each item in the Maintenance Schedule in this Owner’s Manual is
performed with the frequency indicated, by a qualified, licensed technician, and that the
Maintenance Schedule is properly filled out (ie names, signature, date, and action taken)
when the item is completed. ANY FAILURE TO CARRY OUT THE REQUIRED
MAINTENANCE AND SERVICING REQUIREMENTS, AND ANY FAILURE TO PROPERLY
FILL OUT THE MAINTENANCE SCHEDULE, WILL VOID YOUR WARRANTY.
Warning
DO NOT: Place articles on or against this appliance.
DO NOT: Use or store flammable materials near this appliance
DO NOT: Spray aerosols in the vicinity of this appliance while it is in operation.
DO NOT: Modify this appliance.
IMPORTANT
If for any reason your heater experiences,
a POWER FAILURE, the “Pilot Flame” is
TURNED OFF, or GOES OUT, a period of up to
5 minutes is required for the heater to reset.
If the heater has not reset, the
“Gas control knob” will NOT turn easily.
PLEASE DO NOT FORCE
Damage to the mechanism may occur.
Care Instructions
External surfaces should be cleaned with warm water and detergent with the heater turned off.
Do not use abrasive cleaners as scratching of the surface will occur.
Heat Setting
- Turn gas control knob anti-clockwise to
desired heat setting between “1” and
“7”.
- The heater will automatically adjust the
gas flow to maintain the room
temperature corresponding to the
selected heat setting.
To Increase Heat Setting
- Turn gas control knob anti-clockwise
towards “7”.
To Decrease Heat Setting
- Turn gas control knob clockwise
towards “1”.
To Turn Off Main Burner (Pilot-Stand by)
- Turn gas control knob clockwise
to a position between the word PILOT
& the symbol .
(see Figure 1 below)“Pilot zone”
It is recommended that the pilot be
left in operation during the heating
season.
To Turn Off Completely (end of heating
season)
- Turn gas control knob clockwise
to the “0” position.
Figure 1:
To Turn Off Main Burner (Pilot-Stand by)
Heater will now only re-start when control knob
is turned to a heat setting of 1 to 7.
“Pilot zone”


Produktspezifikationen

Marke: Braemar
Kategorie: Heizung
Modell: Ecostar WF2000

Brauchst du Hilfe?

Wenn Sie Hilfe mit Braemar Ecostar WF2000 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Braemar

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung fĂĽr -Kategorien-