Intrusion Alarm Systems | D9127 Series POPIT Modules
D9127 Series POPIT Modules
www.boschsecurity.com
uProvides point identification of initiating devices
uSupervises wiring to devices for circuit integrity
uExpands the number of points in the system
uCompact size
uTerminal connections for reliability
The D9127 Series POPIT Modules includes the D9127T
(with magnetic tamper switch) and the D9127U
(without tamper). They are used with a D8125 or B299
Addressable Expansion Module when there is a need
to expand a compatible control panel beyond its
standard number of on-board initiating zones or
points. Future system expansion is very economical as
D9127 Series POPITs can be added anywhere along
the two-wire data expansion loop from the D8125 or
B299 modules.
Both modules include proven technology that
combines zone and point supervision with individual
device addressing on one pair of wires. Screw
terminals provide reliable connections for the data
expansion loop and supervised sensor loop wiring.
Install a 33 kΩ end-of-line resistor at the farthest point
on the loop for proper supervision. The units are small
and easily installed in standard outlet boxes, above
false ceilings, closets, or other accessible locations.
Certifications and approvals
Region Regulatory compliance/quality marks
USA UL
UL UL 365 - Police Station Connected Bur-
glar Alarm Units
UL UL 464 - Standard for Audible Signal Ap-
pliances
UL UL 609 - Standard for Local Burglar
Alarm Units and Systems
UL UL 864 - Standard for Control Units and
Accessories for Fire Alarm Systems
(10th edition)
UL UL 985 - Household Fire Warning Sys-
tem Units (6th edition)
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
UL UL 1610 - Central Station Burglar Alarm
Units
UL UL 1635 - Standard for Digital Alarm
Communicator System Units
Region Regulatory compliance/quality marks
FM
CSFM California State Fire Marshal
FDNY-
CoA
6059 [D9412GV3 & D7412GV3]
FDNY-
CoA
6286 D7412GV4 D9412GV4 NYC COA
6286 2018-2021
FDNY-
CoA
6196
Australia CTICK C-Tick
Canada ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar
Alarm
ULC S303 - Local Burglar Alarm Units and
Systems
ULC ULC 365 - Police Station Connected Bur-
glar Alarm Units
ULC APOU7.S1871 Proprietary Alarm Units
Certified for Canada
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
Installation/configuration notes
Compatibility Information
Control Panels All G Series control panels, D9412, D7412,
D7212, D7212B1, D9112, D9112B1,
D8112G1, D8112G2, and D9124
Modules D8125, B299
The D8125 or B299 POPEX Modules are required. The
D9127 modules are wired in parallel on the D8125 or
B299 data loops.
Number of POPIT Modules per Control Panel
D7212G, D7212GV2, D7212GV3 32 D9127 POPITs
D7212B1 40 D9127 POPITs
D7212, D7412, D7412G, D7412GV2,
D7412GV3, D7412GV4
67 D9127 POPITs
D9124 119 D9127 POPITs
D9112B1 126 D9127 POPITs
D9112, D9412, D9412G, D9412GV2,
D9412GV3, D9412GV4
238 D9127 POPITs
B8512G (D8125) 67 D9127 POPITs
B8512G (B299) 91 D9127 POPITs
B9512G (D8125) 238 D9127 POPITs
B9512G (B299) 591 D9127 POPITs
Wiring Considerations
Wire Size
Wire Size
Wire Size
Wire SizeWire Size Maximum Length of all Data
Maximum Length of all Data
Maximum Length of all Data
Maximum Length of all DataMaximum Length of all Data
Expansion Loops Combined
Expansion Loops Combined
Expansion Loops Combined
Expansion Loops CombinedExpansion Loops Combined
0.8 mm (22 AWG) 549 m (1800 ft)
1.0 mm (20 AWG) 881 m (2890 ft)
1.2 mm (18 AWG) 1402 m (4600 ft)
1.5 mm (16 AWG) 2231 m (7320 ft)
1.8 mm (14 AWG) 3551 m (11650 ft)
D8125 or B299 POPIT Loops
Use one two-wire data expansion loop, or distribute
the POPITs on multiple loops. The maximum lengths
shown in the following table are for all data expansion
loops combined connected to the same D8125 or
B299 module. Setting DIP switches on the POPIT
modules assigns them to point numbers. The switch
setting on each POPIT assigns it a point number,
regardless of its physical location.
POPIT to Sensor Loops
The number of detection devices each sensor loop can
supervise is limited only by the resistance on the loop.
Resistance on each sensor loop must be less than
100 Ω not including the end-of-line (EOL) resistor.
Certain UL and National Fire Protection Association
(NFPA) applications can limit the number of detection
devices. Consult the appropriate UL or NFPA
standards.
Terminate each POPIT sensor loop with the 33 kΩ EOL
resistor included with each POPIT.
Use a twisted-pair wire (six twists per foot) in all
POPIT installations for both the data expansion loop
wiring and the POPIT sensor loops. Run wires away
from AC sources to prevent AC induction.
Technical specifications
Environmental Considerations
Relative humidity Up to 93% non-condensing
Temperature
(operating)
0°C to +60°C (+32°F to +140°F)
For UL Certifcated Installations, 0
°
C to +50
°
C
(+32
°
F to +122
°
F)
Properties
Color Off white
Dimensions 8.1 cm x 3.8 cm x 2.4 cm
(3.2 in. x 1.5 in. x 0.9 in.)
Material UL Listed fire-resistant
2 | D9127 Series POPIT Modules
Power Requirements
Current draw 0.8 mA maximum
Resistance Maximum increase in resistance on the POPIT
loop is 1000 Ω. Maximum resistance between
the D8125 or B299 modules and each POPIT
is 90 Ω.
Voltage (operating) 12 VDC nominal
Sensor Loop
Resistance Maximum resistance on the sensor loop is
100 Ω.
Response time 1 sec approximately
Ordering information
D9127T POPIT input module with tamper
Includes a magnetic tamper switch.
Order number D9127T
D9127U POPIT input module without tamper
No tamper switch.
Order number D9127U
D9127T-CHI POPIT input module with tamper
Includes a magnetic tamper switch.
Order number D9127T-CHI
3 | D9127 Series POPIT Modules
Represented by:
Europe, Middle East, Africa: Germany: North America: Asia-Pacific:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
emea.securitysystems@bosch.com
emea.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.boschsecurity.com
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
onlinehelp@us.bosch.com
www.boschsecurity.us
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
© Bosch Security Systems 2020 | Data subject to change without notice
2538178443 | en, V15, 25. Jun 2020


Produktspezifikationen

Marke: Bosch
Kategorie: Nicht kategorisiert
Modell: D9127U

Brauchst du Hilfe?

Wenn Sie Hilfe mit Bosch D9127U benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Bosch

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-