Blaupunkt SR-S1 Bedienungsanleitung
Blaupunkt
Alarmanlage
SR-S1
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Blaupunkt SR-S1 (2 Seiten) in der Kategorie Alarmanlage. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/2
Wireless Indoor Siren (SR S1)-
P
Pa
ar
rt
ts
s
D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
1. Mounting Holes x 4
2. Tamper Switch
The tamper switch protects the from being opened.cover
3. Function Switch Block
Contains 7 to enable the learning mode and to set DIP Switches
the alarm period of siren.
P
Pa
ac
ck
ka
ag
ge
e
C
Co
on
nt
te
en
nt
t
1 x Indoor Siren
4 x large wall plugs and screws
4 V x 1.5 D alkaline batteries
D
Di
ip
p
S
Sw
wi
it
tc
ch
h
1. Open the front cover
2. Open the battery cover to insert batteries.compartment
3. ocate the L Function Switch Block. Use a sharp bject to o set
Dip SW3 & SW4 on the function switch block to your desired
alarm length.
4. ontrol anel Enter learning mode for your c p .
5. Slide the position Dip SW1 to ON . SR S1- will enter learning
mode. he code After 3 seconds, t Siren will send a learning
and emit a beep to confirm.
6. If the Control Panel receives the learning signal, please refer
to the Control Panel manual to complete the learning process.
When learning is complete, the Control Panel will send signal
to the The Siren to confirm. Siren will sound a short beep
again to indicate learning is successful.
If the Control Panel fails to receive a learning code, slide Dip
SW1 back to OFF, and then ON position again to enter
learning mode again.
7. does no I f the Siren t respond, please remove the Siren from
the control panel and repeat steps 4-6 again.
8. S lide Dip the SW1 to OFF position to leave learning mode. If
you do t slide Dip SW1 back to OFF position, the no Siren will
automatically leave the learning mode in one hour.
The Indoor Siren has 4 mounting holes on the back cover for wall
mounting.
Before Installation, refer to your Control Panel manual to
temporarily disable the Siren Tamper function to avoid
accidental alarm trigger.
1. Use the 4 mounting holes on the back to mark position on the
wall.
2. Drill holes into the wall using the mounting holes as template,
insert wall plugs if required,
3. Fix the base onto the wall with the screw and plugs provided.
4. Replace the front cover onto the base.
5. Enab le the Siren Tamper function on you Control Panel.
L
L
e
e
a
a
r
r
n
n
i
i
n
n
g
g
SW1
Siren Learning
OFF
Normal operation
ON
Learn-in mode
SW2
Reserved
SW3
SW4
Siren Duration
OFF
OFF
3 min.
ON
OFF
5 min.
OFF
ON
10 min.
ON
ON
1 second (test)
SW5
Reserved
SW6
Memory Reset
OFF
Normal
ON
Clear Memory
SW7
Supervision
OFF
Supervision function disable
ON
Supervision function enable
 For further detail please see
L
Le
e
a
ar
rn
ni
in
ng
g
aanndd
O
Op
pe
er
ra
at
ti
io
on
n.
.
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
Mounting Holes
x 4
TTaammppeerr SSwwiittcchh
The Siren is protected by a tamper switch which will be activated
if the Siren is cover opened. When installing the Siren, please
make sure the tamper switch is properly compressed against the
front cover.
Before installing the Siren, changing mounting location or
batteries, please make sure to disable the tamper switch
temporarily using your Control Panel’s Siren Tamper function and
enable the tamper switch again after finish working on the Siren.
Please refer to your Control Panel manual for detail.
SSiirreenn AAuuddiibbllee PPeerrffoorrmmaannccee
The Siren produces a minimum of 104 dBA sound pressure at 1
meter range when activated.
For Burglar and Panic Alarm, the Siren gives a continuous alarm
sound.
For Fire / Water alarm, the Siren gives an intermittent alarm
sound of 2 sec siren followed by a 1 sec interval. -
The Siren is silenced when either the programmed siren length
expires or when the turn off the Control anel P is disarmed to Siren.
Please refer to Dip Switch table above to set your desired alarm
length through Dip Switch SW3 and SW4 setting.
Audio Status Indication Table
The Siren will sound indication beeps according to different status,
please refer to table below.
SSiirreenn AAuuddiioo
Arm/Home 1 beep*
Disarm 2 beeps*
Arm (Low Battery) 5 beeps
Disarm (Low
Battery) 5 beeps
Arm (Tamper) 5 beeps
Disarm (Tamper) 2 beeps*
Previous alarm
warning 3- second beep
Entry/Exit Sound Count-down beeps
* Siren Audio indication will be effected by the Confirmation
O N / OFF setting in your Control Panel settings.
B
Ba
at
tt
te
er
ry
y
The Siren uses four alkaline batteries 1.5V D as its power source.
It also features low battery detection function to notify the Control
Panel when battery voltage is low.
When the Siren is on low battery, follow the procedure below to
change the batteries.
1. Temporarily amper protection function disable the Siren’s t
(please refer to your manual Control Panel for detail). The
Siren will sound a beep to indicate the tamper is disabled.
2. Remove the front cover.
3. and Remove the four screws fixing the battery compartment
take off the compartment lid.
4. old Remove the batteries and press the Tamper Switch twice
to discharge.
5. new Insert the D cell alkaline batteries into the battery
compartment polarity according to correct .
6. The Siren will emit beeps when the last battery is inserted.
7. Replace the battery compartment lid and front cover
8. amper protection on Enable the t functi through your Control
Panel. The Siren will sound a beep to indicate.
E
En
nv
vi
ir
ro
on
nm
me
en
nt
ta
al
l
C
Co
on
nd
di
it
ti
io
on
n
- -10°C to 40°C, relative humidity 85% non condensing.
R
Ra
ad
di
io
o
868 MHz
O
Op
pe
er
ra
at
ti
io
on
n
SSppeecciiffiiccaattiioonn
Produktspezifikationen
Marke: | Blaupunkt |
Kategorie: | Alarmanlage |
Modell: | SR-S1 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Blaupunkt SR-S1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Alarmanlage Blaupunkt
4 August 2024
26 Juli 2024
24 Juli 2024
24 Juli 2024
29 Mai 2024
23 Mai 2024
21 November 2023
20 September 2023
8 Juli 2023
29 Juni 2023
Bedienungsanleitung Alarmanlage
- Alarmanlage Basetech
- Alarmanlage Hama
- Alarmanlage Nedis
- Alarmanlage Brennenstuhl
- Alarmanlage Bosch
- Alarmanlage Velleman
- Alarmanlage Eminent
- Alarmanlage IKEA
- Alarmanlage Schwaiger
- Alarmanlage König
- Alarmanlage Renkforce
- Alarmanlage Schneider
- Alarmanlage Dometic
- Alarmanlage Pyle
- Alarmanlage Vivanco
- Alarmanlage Abus
- Alarmanlage Elro
- Alarmanlage EZVIZ
- Alarmanlage Imou
- Alarmanlage Olympia
- Alarmanlage Smartwares
- Alarmanlage Yale
- Alarmanlage Gigaset
- Alarmanlage Burg Wächter
- Alarmanlage Honeywell
- Alarmanlage Redmond
- Alarmanlage Doro
- Alarmanlage Kodak
- Alarmanlage Techly
- Alarmanlage Schellenberg
- Alarmanlage Xavax
- Alarmanlage Monacor
- Alarmanlage FireAngel
- Alarmanlage Kidde
- Alarmanlage Optex
- Alarmanlage Aritech
- Alarmanlage Desq
- Alarmanlage M-e
- Alarmanlage Eufy
- Alarmanlage Grothe
- Alarmanlage EVOLVEO
- Alarmanlage Ring
- Alarmanlage Swann
- Alarmanlage Chuango
- Alarmanlage Hikvision
- Alarmanlage Electia
- Alarmanlage Somfy
- Alarmanlage KlikaanKlikuit
- Alarmanlage Protector
- Alarmanlage Steren
- Alarmanlage Woonveilig
- Alarmanlage X4-Tech
- Alarmanlage Vimar
- Alarmanlage Dahua Technology
- Alarmanlage Tzumi
- Alarmanlage FBT
- Alarmanlage Pentatech
- Alarmanlage Olymp
- Alarmanlage Chacon
- Alarmanlage Kemo
- Alarmanlage ORNO
- Alarmanlage DSC
- Alarmanlage Cordes
- Alarmanlage Schabus
- Alarmanlage Qolsys
- Alarmanlage Gripo
- Alarmanlage ETiger
- Alarmanlage ConiuGo
- Alarmanlage Bearware
Neueste Bedienungsanleitung für -Kategorien-
3 Oktober 2024
3 Oktober 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024