Bioland T103 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Bioland T103 (2 Seiten) in der Kategorie Thermometer. Dieser Bedienungsanleitung war für 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
FAST DIGITAL THERMOMETER
Model T 103
DESCRIPTION OF THIS PRODUCT
Display field
Measuring sensor ON/OFF button
We congratulate you on your purchase of this thermometer. To correctly utilize all
the advantages of this product, you should familiarize yourself with these operating
instructions before using the thermometer the first time. Then keep these
instructions in a safe place for future reference.
SPECIAL FEATURES
Maximum thermometer:
Acoustic signal:
Automatic self-test:
Temperature measurement: up to 10 seconds fast measurement of the body
Digital display:
Memory:
Automatic switchoff:
100% waterproof:
Flexible tip:
Battery:
In each case the highest measured temperature is
displayed until the appliance switches off.
indicates appliance ready for use and
measurement completed .
guarantees a specified measuring accuracy for each
temperature reading! ERR error is immediately indicated if any deviation
is registered.
temperature reading.
for temperature changes as minor as 0.1 .
automatic storage of last measured temperature.
after approx.10 minutes-for longer battery life.
can be completely immersed for cleaning.
can be bent up to 45 .
1.5/1.55V
•
• 《 》
《 》
•
《 》﹙ ﹚
•
• ℃
•
•
•
• °
•
IMPORTANT SAFETY INSTRUCTIONS
•
•
•
•
• °
• ℃ ﹗
The thermometer is suitable exclusively for measurement of the body
temperature!
The minimum measurement time until the signaling tone [beep] must be
maintained without exception!
The thermometer contains small parts (battery, etc.) that can be swallowed by
children. Therefore never leave the thermometer unattended to children.
Protect the thermometer from hitting and striking!
Avoid bending the tip more than 45 !
Avoid ambient temperatures above 60 .NEVER boil the thermometer
FUNCTION TEST
ERR
BATTERY REPLACEMENT
To turn on the thermometer, push the button over the display window; a short
signaling tone [beep] signals thermometer ON. A display test is performed by
an Lo and a flashing
appear at the upper right of the display. The thermometer is now ready for use.
Proper functioning of the thermometer is tested automatically each time it is turned
on. If a malfunction is detected(measurement inaccuracy), this is indicated by
on the display, and a measurement becomes impossible. In this case, the
thermometer must be replaced.
When the symbol appears in the lower right of the display, the battery is
exhausted and needs replacing. For the battery replacement please remove the
compartment lid of the thermometer. Replace the exhausted battery by positioning
the + at the top. Make sure a battery of the same type is on hand. Batteries can be
purchased at any electrical goods shops. For battery disposal please refer to
safety instructions .
《 》
《 》 《℃》
《 》
《 》
《 》
USING THE THERMOMETER
STORAGE OF MEASURED VALUES
During a measurement, the current temperature is displayed continuously. The
symbol flashes during this period of time. If the signaling tone sounds(beep-
beep-beep-beep 10 times) and the is no longer flashing, this means that the
thermometer is ready for reading. To prolong the life of the battery, turn it off after
use by pressing the operating button briefly, otherwise the thermometer will
automatically turn off after about 10 minutes.
《℃》
《℃》
This device stores the last reading automatically. When you turn on the device, it
displays the last reading automatically right after the display check.
MEASURING METHODS
In the mouth (oral)
In the anus (rectal)
In the armpit (axillary)
Position the thermometer in one of the two pockets under the tongue, to the left or
right of the root of the tongue, The measuring sensor must be in good contact with
the tissue. Close your mouth and breath evenly through the nose to prevent the
measurement from being influenced by inhaled/exhaled air.
Approx. measuring time: 20 seconds.
This is the most reliable measuring method, and is especially appropriate for
infants and small children. Carefully insert the tip of the thermometer 2 to 3 cm
into the anal aperture.
Approx. measuring time: 10 seconds.
.
From a medical viewpoint, this method will always provide inaccurate readings,
and should not be used if precise measurements are required.
Approx. measuring time: 30 seconds.
• Use only the commercial disinfectants listed in the section cleaning 《and
disinfecting to clean the thermometer. The thermometer must be intact when 》
immersed in liquid disinfectant.
Warning﹕The thermometer contains a long-life battery. For disposal, please
comply with local regulations for special waste.
•The manufacturer recommends to verify the accuracy by an authorized
laboratory every 2 years.
tuning on all symbols for about 1 second, then display last measurement memory
(only valid to an successful last measurement),
measured temperture already reached to a stable level, completed measurement,
TURNING ON THE THERMOMETER
WARRANTY
We grant you a year warranty after the date of purchase. Any damage causes
by improper handling shall not be covered by the warranty. Batteries and
packaging are also excluded from the warranty. All other damage claims excluded.
A warranty claim must be submitted with the purchase receipt.
V1.0
TECHNICAL SPECIFICATION
Type Maximum thermometer
Measuring range 32.0 C~ 42.9 C
Temp.<32.0 C: display Lo for low" "
Temp.>42.9 C: display Hi for high" "
Resolution 0.1 C
Accuracy + 0.1 C for measuring range 35.5 C ~ 42.0 C
+ 0.2 C for other measuring range
Response time(in water bath) 23+2 C 37+2 C, within 15 seconds
Measurement time Oral: 20+5 sec. Underarm: 30+5sec.
(for reference only, it differs from people to people)
Power source One 1.5V
battery, type LR41, 192, SR41, 392 or equivalent
Power consumption 0.15mW(Max.)in the measuring mode
Memory function Turn on the unit it automatically display the last reading for 2
seconds after display check.
Auto Power-Off function Around 8 min. 40sec. +1min. after the measurement completed
Waterproof function The whole unit is resistant to water
Operating temperature 10~40 C, 15~95%R.H.
noncondension
Storage temperature -20 C to + 60 C
Self-test function It runs automatically after power on. Display Err when system " "
malfunction
Reference to standards EN12470-3:2000,clinical thermometers
ASTM E1112-00 standard
Signaling tone For signaling that the thermometer is ready to use and that the
measurement is completed
Rectal: 10+5 sec.
CLEANING AND DISINFECTING
Note:
The thermometer is 100% waterproof. You can clean it by washing with soap and
warm water or by wiping it with 70% isopropyl alcohol. Then wipe dry with a soft,
clean cloth.
DO NOT BOIL OR CLEAN IN THE DISHWASHER. This will damage your
thermometer and will void the warranty.
Any other cleaning solution, dilution or cleaning method can cause a
malfunction of the thermometer!
1


Produktspezifikationen

Marke: Bioland
Kategorie: Thermometer
Modell: T103

Brauchst du Hilfe?

Wenn Sie Hilfe mit Bioland T103 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten