Page 1/10
6LE005154A 2017-11
Motion detector 1.1 m
Order no. 8534 11 xx
Motion detector 2.2 m
Order no. 8534 21 xx
Operating instructions
1. Safety instructions
Electrical equipment may only be installed and assembled by a qualiî‚¿ed electrician in ac-
cordance with the relevant installation standards, regulations, directives and safety and
accident prevention directives of the country.
Failure to comply with these installation instructions may result in damage to the device,
î‚¿re or other hazards.
Due to its detection behaviour the device is not suitable for use in burglary detection or
alarm systems.
These instructions are an integral component of the product and must be retained by the
end user.
2. Design and layout of the device
(3)
(4)
(5)
(2)
(1)
(6)
Figure 1: Design and layout of the device
(1) Insert (see "Accessories", not in scope of delivery)
(2) Frame (not within scope of delivery)
(3) Application module
(4) Motion detector design cover
(5) Screw for dismantling protection (not for design lines R.1/R.3)
(6) Interface between insert/application module
Page 2/10
6LE005154A 2017-11
3. Function
Correct use
–Automatic switching of lighting depending on heat motion and ambient brightness
–Application module for switch insert, ush-mounted dimmer or motion detector extension
unit
–
Only suitable for use in indoor areas with no drip and no spray water.
Product characteristics
–Integrated button for selecting operating modes and special functions
–Lockable integrated button
–Operating mode - automatic mode, permanent ON, permanent OFF can be selected
–Display operating mode via LED
–Potentiometer for adjusting the response brightness and detection sensitivity
–Adjustable detection angle for adaptation of the detection area
–
Additional adjustment of the response brightness via Teach-In function
–Party function
–Presence simulation
–Operation on motion detector extension units
–Optional extension unit operation via installation button
Automatic mode
The motion detector detects heat motion caused by people, animals, or objects.
Applied on switch insert:
–The light will be switched on for a (xed) delay time of 3 minutes if movements are
detected in the detection area and the set brightness threshold is undershot. Each detected
movement restarts the delay time.
–The light will be switched off after 3 minutes if no additional movements are detected.
On ush-mounted dimmer:
–The light will be switched on to the switch-on brightness level for a (xed) delay time of 3
minutes if movements are detected in the detection area and the set brightness threshold is
undershot. Each additional movement in the detection area restarts the delay time.
–After the delay time elapses the lighting will be dimmed to 50% of the switch-on brightness-
level and will remain at this brightness level for 30 s (switch-off pre-warning). Each
movement detected during the switch-off pre-warning restarts the delay time and restores
the switch-on brightness level.
–The light will be switched off if no motion is detected any longer in the detection area and
the set delay time and the switch-off time have elapsed.
On extension unit
–If motion is detected in the detection area of the extension unit, the extension unit insert
sends a pulse to the main unit and then locks for 10 seconds. Recording takes place in-
dependently of the brightness on the extension unit. If motion is still detected after 10 se-
conds, a pulse is sent again.
–Upon receiving an extension unit pulse, the main unit switches the light on for the delay
time, if the set brightness threshold is undershot. Every further extension unit pulse restarts
the delay time of the main unit.
Page 3/10
6LE005154A 2017-11
Performance after mains breakdown/return of mains supply
–Mains breakdown shorter than 0.2 s:
The function is not impaired.
–Mains breakdown longer than 0.2 s:
There is no function during the mains breakdown. The current conî‚¿guration is saved in
non-volatile memory.
–Return of mains supply:
The application module executes an initialisation for approx. 15 s, during which the lighting
will be switched on. Motion detection starts thereafter. If no motion is detected during the
î‚¿rst 5 s, the lighting is switched off. The saved conî‚¿guration is loaded from memory. During
this period local operation via the button or extension unit can be used.
4. Operation
Operating concept
(8)
(7)
Fig. 2: Operating and display elements
(7) Button
(8) Status LED
Operation is executed by pushing the button (7) on the motion detector:
–
A short press of the button switches the operating modes. The operating mode is displayed
via the status LED behind the optics cover of the motion detector.
–Keeping the button pressed activates special functions. Selection of the special functions is
supported by the LED display (Fig. 3).
Function Party function Teach-In Keylock Presence
simulation
Load setting
mode1)
LED display
Hold time
operation
button
> 5 s > 10 s > 15 s > 20 s > 25 s
1) Only on universal switch insert and universal ush-mounted dimmer
Fig. 3: Selection of the special functions and LED display
Selecting the operating mode
Briey press the button repeatedly until the desired operating mode is selected.
The status LED indicates the selected operating mode (see Table 1).


Produktspezifikationen

Marke: Berker
Kategorie: Bewegungsmelder
Modell: 85341185

Brauchst du Hilfe?

Wenn Sie Hilfe mit Berker 85341185 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Bewegungsmelder Berker

Bedienungsanleitung Bewegungsmelder

Neueste Bedienungsanleitung für -Kategorien-