BeamZ BPP100 Bedienungsanleitung
BeamZ
Effektmaschine
BPP100
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für BeamZ BPP100 (24 Seiten) in der Kategorie Effektmaschine. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/24
1
BPP100 PAR64 6 18x W Quad RGBW DMX
Ref. nr.: 1 5 51.24
INSTRUCTION MANUAL
GEBRUIKSAANWIJZING
GEBRAUCHSANLEITUNG
MANUAL DE INSTRUCCIONES
MANUEL D'INSTRUCTIONS
INSTRUKCJA OBSŁUGI
V1 .0
ENGLISH
Congratulations to the purchase of this Beamz light effect. Please read this manual thoroughly prior to using the unit in order to
benefit fully from all features.
Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to
avoid fire and/or electrical shock. Repairs must only be carried out by a qualified technician in order to avoid electrical shock.
Keep the manual for future reference.
- Prior to using the unit, please ask advice from a
specialist. When the unit is switched on for the first time,
some smell may occur. This is normal and will disappear
after a while.
- The unit contains voltage carrying parts. Therefore do
NOT open the housing.
- Do not place metal objects or pour liquids into the unit
This may cause electrical shock and malfunction.
- Do not place the unit near heat sources such as
radiators, etc. Do not place the unit on a vibrating
surface. Do not cover the ventilation holes.
- The unit is not suitable for continuous use.
- Be careful with the mains lead and do not damage it. A
faulty or damaged mains lead can cause electrical shock
and malfunction.
- When unplugging the unit from a mains outlet, always
pull the plug, never the lead.
- Do not plug or unplug the unit with wet hands.
- If the plug and/or the mains lead are damaged, they
need to be replaced by a qualified technician.
- If the unit is damaged to such an extent that internal
parts are visible, do NOT plug the unit into a mains outlet
and DO NOT switch the unit on. Contact your dealer. Do
NOT connect the unit to a rheostat or dimmer.
- To avoid fire and shock hazard, do not expose the unit to
rain and moisture.
- All repairs should be carried out by a qualified technician
only.
- Connect the unit to an earthed mains outlet (220-
240Vac/50Hz) protected by a 10-16A fuse.
- During a thunderstorm or if the unit will not be used for a
longer period of time, unplug it from the mains. The rule
is: Unplug it from the mains when not in use.
- If the unit has not been used for a longer period of time,
condensation may occur. Let the unit reach room
temperature before you switch it on. Never use the unit in
humid rooms or outdoors.
- During operation, the housing becomes very hot. Do not
touch it during operation and immediately after.
- To prevent accidents in companies, you must follow the
applicable guide lines and follow the instructions.
- Secure the unit with an extra safety chain if the unit is
ceiling mount. Use a truss system with clamps. Make
sure nobody stands in the mounting area. Mount the
effect at least 50cm away from inflammable material and
leave at least 1 meter space on every side to ensure
sufficient cooling.
- This unit contains high intensity LEDs. Do not look into
the LED light to prevent damage to your eyes.
- Do not repeatedly switch the fixture on and off. This
shortens the life time.
- Keep the unit out of the reach of children. Do not leave
the unit unattended.
- Do not use cleaning sprays to clean switches. The
residues of these sprays cause deposits of dust and
grease. In case of malfunction, always seek advice from
a specialist.
- Only operate the unit with clean hands.
- Do not force the controls.
- If the unit has fallen, always have it checked by a
qualified technician before you switch the unit on again.
- Do not use chemicals to clean the unit. They damage the
varnish. Only clean the unit with a dry cloth.
- Keep away from electronic equipment that may cause
interference.
- Only use original spares for repairs, otherwise serious
damage and/or dangerous radiation may occur.
- Switch the unit off prior to unplugging it from the mains
and/or other equipment. Unplug all leads and cables
prior to moving the unit.
- Make sure that the mains lead cannot be damaged when
people walk on it. Check the mains lead before every use
for damages and faults!
- -The mains voltage is 220 240Vac/50Hz. Check if power
outlet match. If you travel, make sure that the mains
voltage of the country is suitable for this unit.
- Keep the original packing material so that you can
transport the unit in safe conditions
This mark attracts the attention of the user to high voltages that are present inside the housing and that are of sufficient
magnitude to cause a shock hazard.
This mark attracts the attention of the user to important instructions that are contained in the manual and that he should
read and adhere to.
DO NOT LOOK DIRECTLY INTO THE LENS. This can damage your eyes. Persons who are subject to epileptic attacks
should be aware of the effects that this light effect may have on them.
The unit has been certified CE. It is prohibited to make any changes to the unit. They would invalidate the CE certificate and
their guarantee!
NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5°C/ °F 41 and
35 95°C/ °F.
Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your
dealer about the way to proceed. The specifications are typical. The actual values can slightly change from one unit to the other.
Specifications can be changed without prior notice.
3
UNPACKING INSTRUCTION
CAUTION! Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are
present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if
any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing
materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original
factory box and packing.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The
arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
POWERSUPPLY
On the label on the backside of the controller is indicated on this type of power supply must be connected. Check that the mains
voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The controller must
also be directly connected to the mains and may be used. No dimmer or adjustable power supply.
INSTALLATION
Attention:
• The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
• The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
• -Make sure the area below the installation place is free from unwanted persons during rigging, de rigging
and servicing.
• - -The operator has to make sure that safety relating and machine technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
• - - The operator has to make sure that safety relating and machine technical installations are approved by a
skilled person once a year.
• The fixture should be installed in the position where persons cannot reach and where persons may walk by
or be seated.
CAUTION: Please consider the respective national norms
during the installation! The installation must only be
carried out by an authorized employee or dealers!
CAUTION: When installing the device, make sure there is no
highly in inflammable material (decoration articles,
etc.) in between a distance of min 0.5 meter.
Produktspezifikationen
Marke: | BeamZ |
Kategorie: | Effektmaschine |
Modell: | BPP100 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit BeamZ BPP100 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Effektmaschine BeamZ
8 Oktober 2024
2 Oktober 2024
30 September 2024
30 September 2024
28 September 2024
18 September 2024
17 September 2024
15 September 2024
13 September 2024
13 September 2024
Bedienungsanleitung Effektmaschine
- Effektmaschine NGS
- Effektmaschine Velleman
- Effektmaschine König
- Effektmaschine Pyle
- Effektmaschine Antari
- Effektmaschine Stairville
- Effektmaschine American DJ
- Effektmaschine Karma
- Effektmaschine Adj
- Effektmaschine Behringer
- Effektmaschine Eurolite
- Effektmaschine Showtec
- Effektmaschine Monoprice
- Effektmaschine Lexicon
- Effektmaschine Monacor
- Effektmaschine HQ
- Effektmaschine Viking
- Effektmaschine Elation
- Effektmaschine Cameo
- Effektmaschine HQ Power
- Effektmaschine Qtx
- Effektmaschine Midas
- Effektmaschine Black Lion Audio
- Effektmaschine Martin
- Effektmaschine Steren
- Effektmaschine TCM FX
- Effektmaschine Fun Generation
- Effektmaschine Futurelight
- Effektmaschine IMG Stage Line
- Effektmaschine TC Electronic
- Effektmaschine Lab Gruppen
- Effektmaschine Hazebase
- Effektmaschine Doepfer
- Effektmaschine Chauvet
- Effektmaschine Valueline
- Effektmaschine Laserworld
- Effektmaschine Klark Teknik
- Effektmaschine Eliminator Lighting
- Effektmaschine BoomTone DJ
- Effektmaschine Sagitter
- Effektmaschine Drawmer
- Effektmaschine DJPower
- Effektmaschine The Confetti Maker
- Effektmaschine Blizzard
- Effektmaschine ColorKey
- Effektmaschine Lotronic
- Effektmaschine Valcom
- Effektmaschine Evo-Lite
- Effektmaschine IGS Audio
- Effektmaschine Magmatic
- Effektmaschine Technical Pro
- Effektmaschine Rosco
- Effektmaschine Showven
Neueste Bedienungsanleitung für -Kategorien-
10 Oktober 2024
6 Oktober 2024
2 Oktober 2024
2 Oktober 2024
25 September 2024
24 September 2024
17 September 2024
16 September 2024
14 September 2024
8 September 2024