Instruction Manual
Computer Controlled
A/C - D/C
Sump Pump System
Page 1
Table of Contents
Important Safety Instructions
General . . . . . . . . . . . . . . . . . . . . . . .1
AC Power Requirements . . . . . . . . . .1
Personal Precautions . . . . . . . . . . . . .1
Preparing to Charge . . . . . . . . . . . . .1
DC Connection Precautions . . . . . . . .1
Introduction
Items Included in System . . . . . . . . .2
Additional Items Needed . . . . . . . . . .2
Pump & Pipe
Installation Instructions
Direct Discharge to Outside . . . . . .3,4
Hookup to Existing Discharge Pipe .5,6
Battery Instructions
Preparation of the Battery . . . . . . . . .7
Control Unit Hookup
Positioning the Control Unit . . . . . . . .8
Selecting Main or Backup Mode . . . .8
Positioning the Float Switch . . . . . . . .8
Installing the Battery Fluid Sensor . . .8
Hooking Up the Pump . . . . . . . . . . . .9
Hooking Up the Battery . . . . . . . . . . .9
Initiating the Full Test . . . . . . . . . . . . .9
Understanding the Warning
Lights and Alarms
Silencing the Alarm . . . . . . . . . . . . .10
Battery Hooked Up Improperly . . . . .10
Battery Fluid is Low . . . . . . . . . . . . .10
Battery Discharged . . . . . . . . . . . . .10
Battery Problem . . . . . . . . . . . . . . .10
Cable or Terminal Problems . . . .10,11
Replacing the Battery . . . . . . . . . . .11
Power Failure . . . . . . . . . . . . . . .11,12
Pump Failure . . . . . . . . . . . . . . . . . .12
Pumping . . . . . . . . . . . . . . . . . . . . .12
Pump was Activated . . . . . . . . . . . .12
Replacing the Pump . . . . . . . . . . . .12
Battery Fuse has Blown . . . . . . . . . .13
System Operating . . . . . . . . . . . . . .13
Hour Lights . . . . . . . . . . . . . . . . . . .13
Charging Battery . . . . . . . . . . . . . . .13
Testing the Battery and Pump . . . . .13
Testing the Float Switch . . . . . . . . . .14
Parts & Service Information
Technical Support . . . . . . . . . . . . . .14
Important
Safety Instructions
General
Do not expose the control unit to rain or
snow.
Pull the plug rather than the cord when
disconnecting the control unit.
An extension cord should not be used
unless absolutely necessary. If an
extension cord must be used, be sure
the plug has the same configuration as
the plug on the control unit.
To reduce the risk of electric shock,
unplug the control unit and discon-
nect the cables from the battery be-
fore attempting any maintenance or
cleaning.
Do not disassemble the control unit.
When service is required contact
Glentronics technical support at (800)
991-0466, select option 3.
AC Power Requirements
The control unit must receive 115 volts
AC +/- 5% from the AC outlet. Any
voltage lower than this will cause the
power failure alarm to activate. Lower
voltages can be caused by utility
company brown outs or heavy power
draw from other appliances on the same
circuit.
Personal Precautions
Wear eye protection and avoid touch-
ing your eyes while working near the
battery.
If battery acid contacts skin or clothing,
wash immediately with soap and water.
If acid enters eye, immediately flood eye
with running cold water for at least 10
minutes and get medical attention.
Never smoke or allow a spark or flame
in the vicinity of the battery.
Remove personal metal items such as
rings, bracelets, watches, etc. when
working with a lead-acid battery.
Preparing to Charge
Charge only LEAD-ACID batteries with
the Basement Watchdog control unit. Do
not use the control unit for charging dry-
cell batteries that are most commonly
used with home appliances.
Be sure the area around the battery is
well-ventilated.
When cleaning or adding water to the
battery, gas can be forcefully blown
away by using a piece of cardboard or
other nonmetallic material as a fan.
Clean the battery terminals. Be careful
to keep corrosion from coming in
contact with your eyes.
DC Connection Precautions
Connect and disconnect the battery
cable rings only after removing the AC
power cord from the electric outlet.
Never allow the rings to touch each
other.
Coat the terminals with a thin coat of
petroleum jelly to retard corrosion.
Attach the rings on the ends of the
battery cables to the battery posts and
secure them with wing nuts to insure a
good connection.
Follow these steps when the battery is
installed. A spark near the battery may
cause a battery explosion. To reduce
the risk of a spark near the battery:
Check the polarity of the battery posts.
The POSITIVE (+) battery post usually
has a larger diameter than the
NEGATIVE (-) post.
Connect the large ring on the POSITIVE
(BLACK) wire from the control unit to the
POSITIVE (+) post of the battery.
Connect the small ring on the
NEGATIVE (WHITE) wire from the
control unit to the NEGATIVE (-) post of
the battery.
When disconnecting the control unit,
first disconnect the AC power cord, and
then remove the rings from the battery
terminals.
POSITIVE
POST HAS
LARGER
DIAMETER
NEGATIVE
POST HAS
SMALLER
DIAMETER
Page 2
Introduction
The Basement Watchdog Computer
Controlled A/C-D/C Sump Pump is
strong enough to be used as your main
and only pump, but we recommend using
it as an emergency battery backup
system to support your regular AC sump
pump. It has a state-of-the-art monitoring
system, and it will automatically begin
pumping if your main AC pump fails.
Should any malfunction or emergency
occur that involves the sump pump, the
battery, or the AC power, your Basement
Watchdog sump pump system will sound
an alarm and indicate the nature of the
problem and the solutions by means of a
lighted display on the control panel.
If the main pump breaks or is unable to
keep up with all the incoming water, the
Basement Watchdog pump is capable of
running without discharging the battery
as long as the AC power is on.
The Basement Watchdog A/C-D/C
Sump Pump System includes:
1 Control unit with a float switch and a
battery fluid level sensor
1 Pump with 11/2" PVC pipe adapter
1 Battery box with safety strap
1 Plastic wire tie for mounting the float
switch
1 Battery cap with a hole to
accommodate the fluid sensor
You will also need to supply:
A Basement Watchdog 7.5 Hour
Standby Battery (A maintenance-free
battery is not recommended.)
11/2" PVC pipe and fittings
PVC cement and primer
A rubber union with hose clamps
or a "Y" connector and two (2)
check valves depending on the
installation method you use
Six (6) quarts of 1.265 specific
gravity battery acid
For narrow sump pits you will need
some additional parts:
An "L" bracket at least 6 inches
long. (Preferably one that will not
rust.)
Two (2) stainless steel hose
clamps
One (1) stainless steel screw
(#8-32 x 3
/4"), a matching washer
& nut
BATTERY WIRES
CONTROL UNIT
BATTERY
BOX
CAP
WIRE TIE
FLOAT
SWITCH
PIPE
ADAPTER
PUMP
FLUID SENSOR
Produktspezifikationen
Marke: | Basement Watchdog |
Kategorie: | pomp |
Modell: | BWD12-120C |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Basement Watchdog BWD12-120C benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp Basement Watchdog
29 August 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp Kärcher
- pomp Güde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp Zéfal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024