Baracuda Hydra+ Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Baracuda Hydra+ (14 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/14
H0761800_REVA
HYDRA+ SINGLE SPEED
Installation & Operating Instructions
Baracuda® Hydra+ Single Speed | Installation and Operating Instructions
2
Refer to the following websites for information on warranty and service in your country:
• Australia, NZ, Asia and South Pacific go to www.baracuda.com.au
Date of Installation ____________________
Installer Information _____________________________________________________________
Initial Pressure Gauge Reading (with clean filter) ___________________________________
Pump Model Horsepower __________________________ __________________________
Filter Model ___________________________ _______________________________________
Control Panel Model Serial Number ___________________ ________________________
Notes ___________________________________________________________________________
__________________________________________________________________________________
EQUIPMENT INFORMATION RECORD
Table of Contents
Section 1. Important Safety Instructions 3 .....
Section 2. Installation 7 ......................................
2.1 Location Requirements 7 ...................................
2.2 Hydraulic Connections 7 ....................................
2.3 Electrical Connection 8 .....................................
Section 3. Operation 8 .......................................
3.1 Operating Principle 8 .........................................
3.2 Operating the Pump 8 .......................................
3.3 Priming the Pump 9 ...........................................
Section 4. Maintenance 10 ................................
4.1 Routine Maintenance 10 .....................................
4.2 General Maintenance Information 10 ..............
4.3 Winterising ...................................................... 11
4.4 Servicing ......................................................... 11
Section 5. Repair Parts 11 .................................
Section 6. Troubleshooting 12 ...........................
6.1 Appliance Behaviour 12 ......................................
Section 7. Pump Parts 13 ...................................
Baracuda® Hydra+ Single Speed | Installation and Operating Instructions
3
Section 1. Important Safety Instructions
WARNING
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national,
state, and local codes. When installing and using this electrical equipment, basic safety
precautions should always be followed, including the following:
RISK OF SUCTION ENTRAPMENT HAZARD,
WHICH, IF NOT AVOIDED, CAN RESULT IN
SERIOUS INJURY OR DEATH.
Do not block pump suction, as this can cause severe injury or death. Do not use this pump for
wading pools, shallow pools, or spas containing bottom drains, unless the pump is connected
to at least two (2) functioning suction outlets. Drain covers must be certified to the latest
published edition of ANSI/ASME A112.19.8 or its successor standard ANSI/APSP-16.
In Australia AS1926.3 is also an acceptable standard.
A check valve can interfere with the proper operation of certain Suction Vacuum Release System
(SVRS) products. To avoid possible entrapment hazard, serious injury, or death, make sure to review
the operation/owner's manual of your particular SVRS product before installing the check valve.
To reduce the risk of injury, do not permit children to use this product.
To reduce the risk of property damage or injury, do not attempt to change the backwash
(multiport, slide, or full flow) valve position with the pump running.
Baracuda pumps are powered by a high-voltage electric motor and should be installed by a
licensed or certified electrician or a qualified swimming pool service technician.
The pump is for fixed installations only and to be used in conjunction with swimming
pool equipment (e.g., filters). The pump is to be installed in accordance with the relevant
requirements of the Australian wiring rules AS/NZS 3000. Also refer to the installation
instructions relating to the swimming pool equipment for which the pump will be an integral
part. The pump is to be supplied through a residual current device (RCD) with a rated
residual operating current of 30 mA. If the supply cord is damaged it must be replaced by the
manufacturer or its service agent or similarly qualified person in order to avoid hazard. Only a
qualified person/s, should perform repairs and/or maintenance work on the pump and motor,
including any cabling work to the motor.
Incorrectly installed equipment may fail, causing severe injury or property damage.
Do not connect system to an unregulated city water system or other external source of
pressurized water producing pressures greater than 250 KPA (35 PSI). Trapped air in the
system can cause the filter lid to be blown off, which can result in death, serious personal injury,
or property damage. Be sure all air is out of the system before operating.
To minimize risk of severe injury or death, the filter and/or pump should not be subjected to the piping
system pressurization test. Local codes may require the pool piping system to be subjected to a
pressure test. These requirements are generally not intended to apply to the pool equipment, such as
filters or pumps. Baracuda pool equipment is pressure tested at the factory. If, however, the WARNING
cannot be followed, pressure testing of the piping system must include the filter and/or pump.
Produktspezifikationen
Marke: | Baracuda |
Kategorie: | pomp |
Modell: | Hydra+ |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Baracuda Hydra+ benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp Baracuda
18 August 2024
17 August 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp Kärcher
- pomp Güde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Powerplus
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp Zéfal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
7 Oktober 2024
2 Oktober 2024
1 Oktober 2024