STEP 1 - DETERMINE THE SHAPE OF YOUR OIL TANK
For tank types shown above, select the tank type that is closest in shape to your tank and complete the chart
above.
Note: For unusual tank shapes or to improve the accuracy of the Apollo Smart Monitor you may require a lookup/strapping table. This can be
obtained from your tank manufacturer. Once you have the appropriate informaon, please email it to support@dunravensystems.com. We will
then update the lookup/strapping table so it is compable with our equipment and send it back to you, with instrucons on how to import it into
your Apollo Smart Monitor.
Determine the dimensions of your tank either from manufacturer’s data for the tank or by physically
measuring to complete the chart.
You only need to note the dimensions indicated on the chart shown above.
For bunded tanks the informaon required is for the internal tank only, where the Apollo Smart Transmier
will be located.
To determine the tank height measure from the top of the tank, i.e. where the Apollo Smart Transmier will
be posioned, to the boom of the tank (N.B. of the internal tank in a bunded tank)
Determine the capacity of the tank from the manufacturer’s data for the brimful capacity.
STEP 2 – SETTING UP YOUR APOLLO SMART MONITOR
On rst powering your Apollo Smart Monitor automacally displays its setup mode. The Apollo Smart Monitor
screen will show SETUP 1. One or more segments of the display may be ashing. Flashing segments are circled
in RED in the diagrams. Please follow the steps below to store the sengs to congure your Apollo Smart
Monitor. If you make a mistake and store an incorrect value, simply press ENTER repeatedly unl you return to
the same SETUP number and then select the correct value and press ENTER to store.
SETUP 1 – Seng the me (hrs)
Adjust the hour displayed using
/ . Press ENTER to save.
SETUP 2 – Seng the me
(mins) Adjust minutes dis-
played using / . Press
ENTER to save.
Packaging contains:
Apollo Smart Monitor + mains plug
Apollo Smart Transmier + 2 self
tapping screws + weather seal
Apollo Smart Product manual
This installaon guide
SETUP 3 – Seng the tank type
Select Tank Type i.e. A, B, or C, using
/ to match the Type you noted
from above. Press ENTER to save.
SETUP 4 – Seng the tank
capacity (Ltr) Refer to the
chart above for nominal capaci-
ty and adjust the amount in
Litres displayed using / .
Press ENTER to save.
SETUP 5 – Seng the tank height (cm)
Refer to the chart above for tank
height and adjust the amount in cm
displayed using /. Press ENTER to
save. Note that if Tank Type ‘A’ was
selected, SETUP 6 will be skipped.
SETUP 6 (Type B & C tanks only) -
Seng the tank width (cm)
Refer to the tank chart above for
the width and adjust the amount
in cm displayed using / . Press
ENTER to save.
N.B. If you cannot select the correct dimensions for your tank, conrm that you have selected the correct tank type.
Tips
When taking the tank
dimensions, conrm
tank is prepared for
STEP 4
Have a previous oil bill
handy or call your oil
dealer to nd out
today’s oil cost per
litre.
INSTALLATION GUIDE
Do NOT install/ t your Apollo Smart Transmier to the tank at this me.
Tank Type
Height
(H) cms
Width
(W) cms
Brimful
Capacity
(Ltrs)
Your tank
dimension chart
N/A
Type B - (H >= W) Oval/
cylindrical horizontal
Type A - Rectangular/
cylindrical vercal
Type C - (W > H) Lo prole
STEP 2 – SETTING UP YOUR APOLLO SMART MONITOR—cont’d
SETUP 7 – Seng the fuel cost per litre. Adjust the amount displayed
using /
. Press ENTER to save. (You may need to consult you last
oil bill or your oil supplier)
SETUP 8 – Seng the Fuel The and Low Level Audi-
ble Alarm: Alarm on: The Apollo Smart Monitor will
sound an audible alarm when it detects a sudden drop
in fuel level. It also sounds an audible beep when the
fuel level falls to below 5% of usable fuel remaining.
Alarm o: Disengages all alarms.
For further informaon please refer to Secon 6 of
the Product manual.
Select AL ON/OFF using /
. When the display
shows your preferred seng press ENTER to save.
The SETUP should now be complete. Press SETUP to exit and progress to STEP 3.
On exing SETUP mode the Apollo Smart Monitor temporarily displays CALC.
N.B. If at any stage you exit SETUP mode for any reason, to re-enter simply hold SETUP for 3 seconds and begin again.
STEP 3 - MATCHING THE APOLLO SMART TRANSMITTER TO THE SMART MONITOR
The Apollo Smart Monitor must be in LEARN mode which can be entered in one of two ways:
A) Pressing SETUP aer compleng STEP 2 above
B) By disconnecng and reconnecng the power
When in LEARN mode the display shows ‘Lrn’ in
the main display area. See image 1. LEARN
mode will last for 2 minutes during which me
you must ‘match/pair’ the Apollo Smart Trans-
mier to the Apollo Smart Monitor.
To match/pair the units: Firstly, note the loca-
on of the alignment pin on the right hand side
of the base of the Smart Monitor. See Image 2.
Using the screw hole of the Apollo Smart Trans-
mier slot it onto the pin as shown in Image 3.
The display of the Apollo Smart Transmier
should be facing in the same direcon as the
Apollo Smart Monitor’s display as shown in
Image 4.
When located properly, the bars in the bar
graph display, of both the Apollo Smart Moni-
tor and the Apollo Smart Transmier will ash
and begin to increase in synch together rising
from one bar to ten bars. A connuous audible
beep and ashing LED on the monitor will also
indicate the matching is in progress. Connue
to hold the units in place unl all 10 bars are
ashing. The Apollo Smart Monitor will make
a loud beep. The Red LED on the Apollo Smart
Transmier will ash. They are now matched
and should be separated immediately.
Following the ‘matching/pairing’ the Apollo Smart Transmier will send data connuously to the Apollo
Smart Monitor for approximately 10 minutes. Each me the Apollo Smart Monitor receives a reading, it will
make a clicking noise and the LED on the Apollo Smart Monitor will blink (this is ‘fast’ mode for the trans-
mier).
During this me conrm that the matching procedure was successful by slowly raising and lowering the Apol-
lo Smart Transmier over a at surface and observing that the display in the Apollo Smart Monitor changes .
‘Fast’ mode will stop aer 10 minutes. The Apollo Smart Transmier is now ready to t onto the tank and
should be ed whilst in ‘Fast’ mode.
You should now proceed immediately to STEP 4 and t the Apollo Smart Trans-
mier to your tank. If it is not ed within 10 minutes, the Apollo Smart Monitor
may display an error or an incorrect reading. It may then take up to 2 hours before
the correct tank level informaon is displayed on the Apollo Smart Monitor screen.
Image 3: Correct posioning Image 4 : Alignment
Image 2: Alignment Pin Image 1: ‘Lrn’ mode
STEP 4 INSTALLING THE APOLLO SMART TRANSMITTER ON THE TANK-
The procedure is the same for ng to both old and new tanks. For bunded
tanks ensure that the Apollo Smart Transmier is located on top of the inner
tank.
For Tank with pre drilled 30/32mm hole-
Remove cap from hole and insert transmier, ensuring the weather seal is
securely in place.
Ensure the transmier is vercal on top of the tank
Tighten on to the tank using the 2 stainless steel 19mm long self tapping -
screws supplied. Do not use longer screws. Do not over ghten.-
For Tank without pre drilled holes-
If tank is not pre-drilled, then using a 30/32mm hole saw, drill hole in top of the tank in a suitable area
to allow ease of ng of the transmier and in an area that the transmier can see the tank contents.
Posion so that there are no internal obstrucons, (i.e. Ribs, Stays, Side of Tank, internal equipment),
that may interfere with the ultrasonic signal.
Use Installaon Help Diagram below to ensure suitable ng.
Ensure the transmier is vercal on top of the tank
Tighten on to the tank using the 2 stainless steel 19mm long self tapping screws supplied. -Do not use
longer screws. Do not over ghten.-
Check the Apollo Smart Monitor display two hours aer mounng the transmier and verify that your Apollo
Smart Monitor display shows the tank level in the bar graph area and the oil volume informaon in the main -
display area. If this is not the case consult the ‘Troubleshoong’ secon of the Apollo Smart Product Manual.
N.B. the bar graph displays on the Apollo Smart Transmier and the Apollo Smart Monitor -
may not be the same. The transmier display indicates the top 1m of the tank while the
Apollo Smart Monitor bar-graph displays the oil level relave to the overall tank height.
STEP 5 (OPTIONAL) PERFORM -
ONLY IF THERE WAS A DELAY IN
INSTALLING THE APOLLO SMART
TRANSMITTER ON THE TANK
You only need to complete this step if there was a gap of
more than an hour between compleng STEP 3 and STEP 4.
STEP 5 is otherwise completed automacally as part of STEP
3.
When your Apollo Smart Transmier is installed and has
been conrmed as working reset the usage calculaons by
pressing SETUP for 3 seconds to enter SETUP mode and then
press ENTER repeatedly unl SETUP 9 is shown.
The segments at the boom of the
display will be ashing. Press the
ENTER key for 5 seconds. The screen
will temporarily show ‘CALC’ and then
returns to showing SETUP Seng 1 -
the Time (hrs). Press SETUP to leave
SETUP mode.
Setup of your Apollo Smart Monitor is
now complete and will now begin to it
monitor and track your oil consump-
on on a day to day and week to week
basis. On the ‘Days to Empty’ CUR-
RENT informaon screen, ‘ ‘ will be ---
displayed for 1 week.
Don’t forget to register your warranty!
www.dunravensystems.com
Should you have any queries, please refer to our FAQ secon of the website or
complete our online enquiry form.
The contents and images in this guide are subject to copyright and may not be reproduced without the permission of Dunraven
9-5538- 03
Produktspezifikationen
Marke: | Apollo Ultrasonic |
Kategorie: | Messung |
Modell: | Smart Alarm |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Apollo Ultrasonic Smart Alarm benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Apollo Ultrasonic
2 September 2023
Bedienungsanleitung Messung
- Messung REV
- Messung Voltcraft
- Messung Bosch
- Messung Laserliner
- Messung Velleman
- Messung Alecto
- Messung Beurer
- Messung Bresser
- Messung König
- Messung TFA
- Messung Black And Decker
- Messung Trotec
- Messung DeWalt
- Messung Megasat
- Messung Smartwares
- Messung Garmin
- Messung GOCLEVER
- Messung Perel
- Messung Workzone
- Messung Microlife
- Messung Rossmax
- Messung Amprobe
- Messung Meec Tools
- Messung Metrix
- Messung IHealth
- Messung Ansmann
- Messung Westfalia
- Messung Livington
- Messung Silverline
- Messung Yato
- Messung Be Cool
- Messung Toolland
- Messung AS Schwabe
- Messung Hager
- Messung Kyoritsu
- Messung Eurolite
- Messung GW Instek
- Messung KERN
- Messung Milwaukee
- Messung Eizo
- Messung Testo
- Messung Victron Energy
- Messung Peak
- Messung Kübler
- Messung Carrier
- Messung Lund
- Messung SHX
- Messung Gima
- Messung Testboy
- Messung Danfoss
- Messung Fantini Cosmi
- Messung Multimetrix
- Messung Extech
- Messung BENNING
- Messung Fluke
- Messung FLIR
- Messung Vemer
- Messung Ridgid
- Messung Stabila
- Messung Hikmicro
- Messung Entes
- Messung Gossen Metrawatt
- Messung Hameg
- Messung Joy-it
- Messung Megger
- Messung Muller
- Messung PCE Instruments
- Messung RK Technology
- Messung Sanwa
- Messung Sonel
- Messung Uni-T
- Messung VirtuFit
- Messung Wachendorff
- Messung TFA Dostmann
- Messung Vimar
- Messung Owon
- Messung PeakTech
- Messung Comark
- Messung Dahua Technology
- Messung YSI
- Messung Aluratek
- Messung SRS
- Messung Eltako
- Messung H-Tronic
- Messung HT Instruments
- Messung Beha-Amprobe
- Messung Chauvin Arnoux
- Messung Werma
- Messung Eastron
- Messung Emko
- Messung Pancontrol
- Messung X-Rite
- Messung CESYS
- Messung Trumeter
- Messung Kemo
- Messung ORNO
- Messung Tempest
- Messung TDE Instruments
- Messung Zircon
- Messung Kreg
- Messung BJZ
- Messung Adwa
- Messung Greisinger
- Messung Qubino
- Messung Beckmann & Egle
- Messung Weidmüller
- Messung Janitza
- Messung CEM
- Messung Klein Tools
- Messung Daytronic
- Messung AREXX
- Messung Delta Ohm
- Messung Camille Bauer
- Messung Rigel Medical
- Messung UHoo
- Messung Seaward
- Messung AstroAI
- Messung P3 International
- Messung Seek Thermal
- Messung ClimeMET
- Messung Fixpoint
- Messung Condtrol
- Messung Cliff
- Messung Water-i.d.
- Messung Stahlwille
- Messung KS Tools
- Messung AkYtec
Neueste Bedienungsanleitung für -Kategorien-
4 August 2024
24 Juni 2024
24 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
22 Juni 2024
21 Juni 2024
21 Juni 2024