SRYLBM Rechargeable Lithium Ion Battery Pack
PRODUCT SAFETY DATA SHEET
Version: 1.0
Revision date: September 2 27, 202
SECTION 1: IDENTIFICATION
1.1 Product identifier
Product name:
APC Rechargeable Lithium Ion Battery Pack
Other names:
APC Lithium Ion Battery Pack, APC Rechargeable Battery Cartridge
Model Numbers:
SRYLBM - , 911 7013
Product type:
Battery pack is a manufactured article consisting of a plastic and metal sealed case
containing electronics and cylindrical lithium ion battery/cells. Solid.
Picture of product
covered by this safety
data sheet
1.2 Relevant identified uses of the substances or mixture and uses advised against
Relevant identified use(s): Electric Storage Battery
Use(s) advised against: Transportation
1.3 Details of the supplier of the safety data sheet
Supplier/Manufacturer:
Schneider Electric IT USA, Schneider Electric IT Corp., (formerly APC by Schneider
Electric, APC Sales and Service Corp.)
Address:
SEIT US - 70 Mechanic Street, Foxboro, MA US
Telephone:
+1 800 788 789- -2208 or +1 401- - 5735
E-mail:
http: -//nam en.apc.com/app/ask
Site web:
www.APC.com
1.4 Emergency telephone number (with hours of operation)
For all Service, Technical Support and Emergency Inquires.
1- - - - - - 800 255 3924 North America and 1 813 248 0585 International
Emergency phone number
Call CHEMTREC
1- - - - - - 800 424 9300 North America and 1 703 741 5970 International
SRYLBM to (NA) 2 12
Version: 1.0
Date: September 27, 2022
Internal
SECTION 2: HAZARDS IDENTIFICATION
GHS Classification Categories/OSHA Status/HSC
While this material is not considered hazardous by pursuant to GHS Classification Categories or OSHA
Hazard Communication Standard (29 CFR 1910.1200), this Safety Data Sheet (SDS) contains valuable
information critical to the safe handling and proper use of the product. This SDS should be retained and
available for available for employees and other users of this product.
2.1 Classification of the substance or mixture
According to CLP No 1272/2008:
Not applicable under normal use in accordance with United Nations Conference on Environment and Development
(UNCED) and Occupational Safety & Health A dministration
(OSHA) 29 CFR 1910.1200
2.2 Label elements
Signal Word: NONE
Environment and Development (UNCED) and Occupational Safety & Health Administration
(OSHA) 29 CFR 1910.1200.
Hazard Statements: NONE
Not applicable under normal use in accordance with United Nations Conference on Environment and Development
(UNCED) and Occupational Safety & Health Administration
(OSHA) 29 CFR 1910.1200
Precautionary Statements
P202
Do not handle until all safety precautions have been read and understood.
P210
Keep away from heat/sparks/open flames/hotsurfaces – No smoking.
P370
In case of fire: Use carbon dioxide, dry chemical or water extinguisher.
P402
Store in a dry place
P410
Protect from sunlight.
P501
Dispose of batteries in accordance with applicable hazardous waste regulations
Protective
Clothing
NFPA Rating
EC classification
WHMIS
(Canada)
Transportation
GHS Hazard
Symbol
Not Applicable
with normal use
Not classified as
hazardous
Not Applicable
with normal use
See Section 14
Not Applicable
with normal use
2 .3 Other hazards
Exposure to contents of an open or damaged cell or battery: contact with this material will cause burns
to the skin, eyes and mucous membranes. May cause sensitization by skin contact.
SRYLBM to (NA) 3 12
Version: 1.0
Date: September 27, 2022
Internal
2.4 Other information
The product is a Lithium ion battery and is therefore classified as an article and is not hazardous when used
according to the recommendations of the manufacturer. The hazard is associated with the contents of the battery.
Under recommended use conditions, the electrode materials and liquid electrolyte are non reactive provided that -
the battery integrity remains, and the seals remain intact. The potential for exposure should not exist unless the
cell in the battery leaks, is exposed to high temperatures or is mechanically, electrically or physically
abused/damaged. If the cell in the battery is compromised and starts to leak, based upon the battery ingredients,
the contents are classified as Hazardous.
SECTION 3: COMPOSITION / INFORMATION ON INGREDIENTS
3.1 Substances:
The material does not meet the criteria of a substance in accordance with regulation (EC) No 1272/2008
Chemical Name
CAS Number
Composition (%)
Lithium Nickel Cobalt manganese Oxide (LiNiMnCoO2)
(NMC)
182442 95- -1
40%
Graphite (Carbon)
7782 42- -5
20%
Ethyl Methyl Carbonate
623 53- -0
3%
Dimethyl Carbonate
616 38- -6
7%
Lithium Hexafluorophosphate
21324 40- -3
2%
Aluminum
7429 90- -5
5%
Copper
7440 50- -8
9%
Iron
7439 89- -6
14%
SECTION 4: FIRST AID MEASURES
4.1 Description of first aid measures
General information
The following first aid measures are required only in case of exposure to interior battery components after
damage of the external battery and cell casings .
Undamaged, closed cells do not represent a danger to the health.
Eye contact If IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present
and easy to do. Continue rinsing. If signs/ symptoms develop, get medical attention.
Inhalation
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for
breathing. Administer oxygen if breathing is difficult. Give artificial respiration if victim is not
breathing. Do not use mouth-to-mouth if victim inhaled the substance; give artificial
respiration with the aid of a pocket mask equipped with one-way valve or other proper
respiratory medical device.
Produktspezifikationen
Marke: | APC |
Kategorie: | UPS |
Modell: | Smart-UPS Modular Ultra Accessories SRYLBM |
Brauchst du Hilfe?
Wenn Sie Hilfe mit APC Smart-UPS Modular Ultra Accessories SRYLBM benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS APC
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
5 Oktober 2024
3 Oktober 2024
Bedienungsanleitung UPS
- UPS Approx
- UPS Gembird
- UPS HP
- UPS Voltcraft
- UPS AEG
- UPS Siemens
- UPS IKEA
- UPS Dell
- UPS LC-Power
- UPS Tripp Lite
- UPS GYS
- UPS Adj
- UPS Block
- UPS Digitus
- UPS CyberPower
- UPS Eaton
- UPS EnerGenie
- UPS Emerson
- UPS Furman
- UPS Riello
- UPS Puls Dimension
- UPS Avocent
- UPS Atlantis Land
- UPS Vanson
- UPS Phoenix Contact
- UPS Minuteman
- UPS V7
- UPS Equip
- UPS Salicru
- UPS SurgeX
- UPS Bxterra
- UPS Altronix
- UPS FSP
- UPS Ditek
- UPS PowerWalker
- UPS FSP/Fortron
- UPS East
- UPS Liebert
- UPS Murr Elektronik
- UPS Online USV
Neueste Bedienungsanleitung fĂĽr -Kategorien-
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
2 Oktober 2024