EcoBreeze
A modular economizer that meets the future
cooling and energy ef ciency requirements of
data centers today and tomorrow
The industry’s only modular, indirect economizer,
EcoBreeze is one of several Schneider Electric Data
Center Facility Modules, which help make large data
center deployment fast and easy.
EcoBreeze provides indirect evaporative cooling or air-to-air
heat exchange in one footprint
Right-sized cooling is made possible by individual modules that
can be scaled to capacity as needed
The IT airstream is isolated from the outdoor ambient airstream
Deployment is flexible and cost-effective since the unit is modular
and uses no data center space
The pre-engineered modules can be deployed according to the
data center’s specific redundancy needs
Features and benefits
EcoBreeze
Efficient and effective cooling
Right-sized cooling made possible by individual
50 kW modules that can be grouped up to a
maximum of 200 kW and 400 kW of sensible
cooling per frame
Fully adaptable cooling via EC fan technology
Efcient and effective cooling via total internal
isolation of the IT airstream from the outdoor
ambient airstream
Regulatory compliance with recommendations
and requirements for economization and
efciency (e.g., ASHRAE 90.1 in
North America).
Adaptability
Ability to address any cooling requirement
worldwide via multiple module and frame
voltages/frequencies
Adaptability via the integration of multiple
cooling options in one module footprint: indirect
evaporative, air-to-air heat exchange, and
proportional direct expansion
Ability to control redundancy from the frame
down to the individual module level
Flexible and easy installation
and servicing
Flexible and cost-effective deployment since
the unit uses zero white space within the
data center
Easy installation because of a single
point of connection for water, power, and
communications
Adaptable installation because it can be
deployed with raised or non-raised oor
applications
Safe and easy capacity expansion and
servicing via individual isolation of air, power,
and communications between the frame and
modules
Environmentally friendly
No chemical treatment required due to an
on-board water treatment system
Environmentally friendly because of zero ozone-
depleting proportional R410a refrigerant system
An innovative answer to cooling challenges
Today’s data centers face unprecedented cooling challenges brought on by high-density computing.
Blade servers, for example, generate risky hot spots and therefore require a highly efficient, cost-effective
cooling solution to safeguard availability while also streamlining cooling costs. Cooling also presents
environmental challenges. With local, regional, and federal standards and regulations related to energy
efficiency, now is the time for data centers to adopt economization (“free cooling”) as an innovative
way to reduce energy consumption. EcoBreeze is the Schneider Electric™ answer to meeting the latest
cooling and energy efficiency requirements facing today’s data centers. This innovative cooling approach
employs a modular design for capacity, redundancy, and service flexibility. The efficiency of the system
is rationalized in three forms of cooling to maximize localized climate conditions and ensure the most
efficient and effective form of cooling year round. EcoBreeze employs the fully adaptable cooling of
electronically commutated (EC) fan technology, along with an ozone-friendly proportional refrigerant
circuit, making it one of the most efficient forms of cooling on the market today.
2 | EcoBreeze
Modularity
Reduction in CapEx results from right-sizing your cooling capacity based
on current load with the  exibility to expand later.
Built-in redundancy from modular form factor allows extra capacity to be
incorporated into the system from the module level to ensure availability
at the system level.
Modular design reduces single point of failure issues from the component
to the control level.
The modular design prevents routine maintenance or break/ x repairs from
interfering with system operation.
Total internal isolation of the IT airstream from the
outdoor ambient airstream
Isolation of the airstreams prevents airborne pollutants from entering the
data center environment.
Maintenance costs are reduced since enhanced  ltration requirements
aren’t necessary when outside air is not being introduced into the data
center environment.
Operating costs are less from not needing to pretreat the data center air
due to variations in outside air dew points associated with 100 percent
outside air economizers.
Two forms of economization cooling in one footprint
Indirect evaporative cooling and air-to-air heat exchange in the same
module allow a wider range of economization opportunities than use of just
one form of economization.
Automatic selection of which form of economization should be used
based on ambient conditions provides seamless operation and
maximized ef ciency.
Proportional refrigeration circuit ensures precise discharge temperature
control back to the data center. The proportional operation uses just enough
mechanical cooling to ensure discharge temperatures and minimize power
consumption when mechanical cooling assist is required.
Features and bene ts
3 | EcoBreeze


Produktspezifikationen

Marke: APC
Kategorie: PC Kühlventilator
Modell: EcoBreeze
Gewicht: 1227270 g
Produktfarbe: Weiß
Paketgewicht: 1272730 g
Abmessungen (BxTxH): 2836 x 1014 x 2616 mm
Verpackungsabmessungen (BxTxH): 2921 x 1143 x 2769 mm
Kompatibilität: EcoBreeze