APC Back-UPS Pro BR700G Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für APC Back-UPS Pro BR700G (8 Seiten) in der Kategorie UPS. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/8
Installation and Operation
Back-UPS™ Pro 700
Connect the Battery
Install PowerChute™ Personal Edition Software
1. Connect the supplied USB software interface cable to the data port, and the other end to a computer with access to
the internet.
2. Go to www.apc.com/pcpe
3. Select PowerChute Personal Edition. Then select the appropriate operating system and follow the instructions to
download the software.
Inventory Safety and General Information
Inspect the package contents upon receipt.
Notify the carrier and dealer if there is any
damage.
Read the Safety Guide supplied with this unit
before installing the UPS.
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there
is excessive dust or humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for
proper ventilation.
• The battery typically lasts for three to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality AC power, and frequent
short duration discharges will shorten battery life.
• Connect the UPS power cable directly to a wall outlet. Do not use surge
protectors or extension cords.
Charge the battery for at least 16
hours before use.
bu001a
bu024a
bu025a
bu028a
bu026a
4. APC PowerChute is compatible with a window operating system only. Visit http://www.apc.com/wp/?um=300.
for OS compatibility list.
Back-UPS Pro 7002
Connect the Equipment
Battery Backup and Surge Protected outlets
When the Back-UPS is receiving input power,
the Surge Protection only outlets and the Battery
Backup with Surge Protection outlets will
supply power to connected equipment. During a
power outage or other AC problems, only the
Battery Backup outlets receive power for a
limited time from the Back-UPS.
Connect equipment such as printers, fax
machines, scanners, or other peripherals that do
not need battery backup power to the Surge
Protection Only outlets. These outlets provide
full-time protection from surges even if the
Back-UPS is switched OFF.
Master and Controlled outlets
To conserve electricity, when the device
connected to Master Outlet goes into Sleep or
Standby mode, or turns Off, the Controlled
device(s) will shut down as well, saving
electricity.
Connect a master device, such as a desktop computer or audio/visual receiver to the Master outlet. Connect
peripheral devices such as a printer, speakers, or a scanner to the Controlled outlets.
USB and Serial Data port To use PowerChute Personal Edition, connect the supplied USB software cable or optional
serial cable (not included).
Building Wiring Fault indicator If this indicator is illuminated, there is a problem with the wiring in the building. Contact an
electrician immediately and do not use the Back-UPS.
Controlled by the Master outlets These outlets will disconnect from AC power if the Power Saving Feature is activated and the
Master device goes into Sleep or Standby mode.
Surge Protected outlets These outlets provide full-time surge protection, even when the unit is turned off. During a
power outage these outlets will disconnect from AC power. Connect equipment such as printers
and scanners that do not require battery backup protection.
Battery Backup outlets with
Surge Protection
During a power outage or other AC problems, these outlets provide power from battery.
Connect critical equipment such as desktop computer, computer monitor, modem or other data
sensitive devices into these outlets.
Circuit breaker Use to reset the system after an overload or short circuit.
Master outlet Connect the master device to this outlet, in most scenarios, this will be the main computer.
Gigabit Ethernet surge-protected
ports
Use an Ethernet cable to connect a cable modem to the IN port, and connect a computer to the
OUT port.
Co-axial ports with surge
protection
Use a coaxial cable to connect a cable modem or other equipment to the IN jack, and connect a
computer or other device to the OUT jack.
bu152a
Back-UPS Pro 700 3
Operation
Power-Saving Function
Power-saving outlets can be used to automatically reduce energy consumption. Just plug your computer
into the Master outlet, and when it is turned OFF or goes into “sleep” or “standby” mode, any peripherals
plugged into the Controlled outlets like speakers, scanners or printers, will also shut off automatically,
eliminating needless electricity waste.
Notes: Devices that provide network services (such as routers, modems, or wireless printers) should not be plugged into the
Controlled outlets. The Back-UPS Pro ships with this Power-Saving feature DISABLED. If you wish to use this feature, follow
the instructions below:
Enable the Power-Saving function. Press and hold and simultaneously for two seconds. The MUTE DISPLAY
Back-UPS will beep to indicate that the feature is enabled. The leaf icon on the display will illuminate.
Disable the Power-Saving function. Press and hold and MUTE DISPLAY simultaneously for two seconds. The
Back-UPS will beep to indicate that the feature is disabled. The leaf icon on the display will extinguish.
Setting the threshold. The amount of power used by a device in Sleep or Standby mode varies between devices. It
may be necessary to adjust the threshold at which the Master outlet signals the Controlled outlets to shut down.
1. Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby mode, or turn it
OFF.
2. Press D MISPLAY and UTE simultaneously and hold for six seconds, until the leaf icon flashes three times and the
Back-UPS beeps three times.
3. The Back-UPS will now recognize the threshold level of the Master device and save it as the new threshold setting.
Power-Saving Display
The display interface can be configured to be continuously illuminated, or to save energy, it can be configured to
extinguish after a period of inactivity.
1. Full Time Mode: Press and hold DISPLAY for two seconds. The display will illuminate and the Back-UPS will beep
to confirm the Full-Time mode.
2. Power-Saving Mode: Press and hold DISPLAY for two seconds. The display will darken and the Back-UPS will
beep to confirm the Power-Saving mode. While in Power-Saving Mode, the display will illuminate if a button is
pressed, it then darkens after 60 seconds of no activity.
Unit sensitivity
In situations where the Back-UPS or connected equipment appears too sensitive to input voltage, it may be necessary
to adjust the transfer voltage. Adjust the sensitivity of the Back-UPS to control when it will switch to battery power;
the higher the sensitivity, the more often the Back-UPS will switch to battery power.
1. Ensure the Back-UPS is connected to AC power, but is OFF.
2. Press and hold the button for six seconds. The bar will flash on and off, indicating that the POWER L COAD APACITY
Back-UPS is in programming mode.
3. Press POWER again to rotate through the menu options. Stop at selected sensitivity. The Back-UPS will beep to
confirm the selection.
Generator Sensitivity Default Sensitive Loads
Low sensitivity Medium sensitivity (Default) High sensitivity
78-144 Vac 88-141 Vac 88-137 Vac
Input voltage is extremely low or
high. (Not recommended for
computer loads.)
The Back-UPS frequently switches to
battery power.
The connected equipment is
sensitive to voltage fluctuations.
Produktspezifikationen
Marke: | APC |
Kategorie: | UPS |
Modell: | Back-UPS Pro BR700G |
Brauchst du Hilfe?
Wenn Sie Hilfe mit APC Back-UPS Pro BR700G benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS APC
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
5 Oktober 2024
3 Oktober 2024
Bedienungsanleitung UPS
- UPS Approx
- UPS Gembird
- UPS HP
- UPS Voltcraft
- UPS AEG
- UPS Siemens
- UPS IKEA
- UPS Dell
- UPS LC-Power
- UPS Tripp Lite
- UPS GYS
- UPS Adj
- UPS Block
- UPS Digitus
- UPS CyberPower
- UPS Eaton
- UPS EnerGenie
- UPS Emerson
- UPS Furman
- UPS Riello
- UPS Puls Dimension
- UPS Avocent
- UPS Atlantis Land
- UPS Vanson
- UPS Phoenix Contact
- UPS Minuteman
- UPS V7
- UPS Equip
- UPS Salicru
- UPS SurgeX
- UPS Bxterra
- UPS Altronix
- UPS FSP
- UPS Ditek
- UPS PowerWalker
- UPS FSP/Fortron
- UPS East
- UPS Liebert
- UPS Murr Elektronik
- UPS Online USV
Neueste Bedienungsanleitung für -Kategorien-
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
2 Oktober 2024